Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Apply Date:
05/28/2008
Applicant:
N/A
Description:
TI:OFFICE
Architects:
  • KILGORE, CARLUS EUGENE JR
Contractors:
  • FLEMING WEST L L C

Permit Reviews

Permit Number - T08CM01727
Permit Status: C of o
Permit Description: TI:OFFICE
Start Date Submittal Complete Date Status  
05/28/2008 PLANS OK TO SUBMIT - 3RD PARTY 05/29/2008 COMPLETED Review Details
05/29/2008 3RD PARTY REVIEW-COMMERCIAL TI 07/07/2008 COMPLETED Review Details
07/07/2008 POST 3RD PARTY REVIEW 07/08/2008 COMPLETED Review Details
09/23/2008 3RD PARTY REVIEW-REVISION/OTHER 09/24/2008 COMPLETED Review Details
12/15/2008 3RD PARTY REVIEW-REVISION/OTHER 01/12/2009 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T08CM01727
Permit Status: C of o
Permit Description: TI:OFFICE
Total Outstanding Activity Conditions - 1
Date Name
05/28/2008 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T08CM01727
Permit Description: TI:OFFICE
Total Completed Inspections - 27
Date Description Inspector Results Comments
07/18/2008 PLUMBING - ROUGH, SOIL RRICH Approved IVRS - Inspection :*
08/01/2008 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection :*
DWV THRU ROOF TEST OK
WATER DISTRIBUTION OK
08/06/2008 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
1) EXHAUST DUCT NOT SIZED PER PLAN
2) EXHAUST FANS NOT PER PLAN
3) INSULATE CONDENSATE PIPE IN WALL
4) INSTALL ALL DUCT WORK PER PLANS AND DETAILS
5) PROVIDE SCREWS IN EXHAUST DUCT CONNECTIONS
6) ALL TAPE MUST BE UL LISTED 181
7) OK TO SHEETROCK HARD LIDS AND WALLS
8) FAN COIL NOT HUNG PER DETAIL
08/08/2008 FRAMING GDABBS Approved IVRS - Inspection :*
08/13/2008 SHEET ROCK NAILING GDABBS Approved IVRS - Inspection :*
09/03/2008 PLUMBING - PROGRESS RRICH Approved IVRS - Inspection :*
CLOSET FLANGES OK
09/03/2008 PLUMBING - SEWER HCS CONNECT RRICH Approved IVRS - Inspection :*
09/03/2008 PLUMBING - YARD WTR LINE/TEST RRICH Approved IVRS - Inspection :*
09/10/2008 ELECTRIC - ABOVE CEILING RJIROUDE Approved IVRS - Inspection :*
09/10/2008 BUILDING ABOVE CEILING GDABBS Approved IVRS - Inspection :*
09/10/2008 PLUMBING - ABOVE CEILING RLEDONNE Approved IVRS - Inspection :*
09/12/2008 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
DRAIN PAN MUST BE MIN. 1 1/2" LARGER THAN FAN COIL.
OK FOR CEILING TILES.
LEAVE OUT AROUND FAN COIL.
09/12/2008 TEP CLEARANCE - PM JWEATHER Approved TEC CLEARED FOR #150 PER R. JIROUDEK
09/17/2008 MECHANICAL - PROGRESS JMILITEL Approved IVRS - Inspection :*
09/17/2008 NPPO - FINAL ACONNOR Approved
09/17/2008 LANDSCAPE - FINAL ACONNOR Approved
09/17/2008 SIGN - FINAL JYBARRA Approved IVRS - Inspection :*
09/17/2008 FIRE SPKLR - FINAL LTHOMAS Approved
09/17/2008 FIRE - FINAL LTHOMAS Approved
09/19/2008 RIGHT OF WAY - FINAL MCASTRO Approved PER EMAIL
09/26/2008 MECHANICAL - FINAL JMILITEL Approved CONDENSING UNIT OK
HAVE PLANS REVISED IF CHANGING DETAILS ON COOLER ANGLE IRON STANDS
PROVIDE BACKDRAFT DAMPERS
09/29/2008 BUILDING - FINAL GDABBS Approved IVRS - Inspection :*
OK TO APPLY FOR TCO
09/29/2008 ENGINEERING - FINAL NKALAHAR Approved TRASH ENCLOSURE REMOVED PER LOREN 9/26 REVISION
09/29/2008 ELECTRIC - FINAL RJIROUDE Approved IVRS - Inspection :*
09/29/2008 ELECTRIC - PROGRESS RJIROUDE Approved IVRS - Inspection :*
09/29/2008 ELECTRIC - INTERMEDIATE RJIROUDE Approved IVRS - Inspection :*
10/01/2008 PLUMBING - FINAL RRICH Approved IVRS - Inspection :*
PER REDLINE ON SITE FOR ADDITION OF CUP SINK WHICH WILL REQUIRE A REVISED CITY APPROVED PLAN FOR FINAL.
INSTALLATION IS COMPLETE. RECEIVE BACTERIA REPORT FOR POTABLE WATER.

Documents

File Name Document Type  
TEMP C OF O_10-02-2008.TIF CERT OF OCC VIEW
C OF O_02-05-2009.TIF CERT OF OCC VIEW
001__T1.1.TIF CONSTRPLANS VIEW
002__D-2.TIF CONSTRPLANS VIEW
003__A1.0.TIF CONSTRPLANS VIEW
004__A1.1.TIF CONSTRPLANS VIEW
005__A1.2.TIF CONSTRPLANS VIEW
006__A2.1.TIF CONSTRPLANS VIEW
007__A3.1.TIF CONSTRPLANS VIEW
008__A4.1.TIF CONSTRPLANS VIEW
009__A5.1.TIF CONSTRPLANS VIEW
010__A6.1.TIF CONSTRPLANS VIEW
011__A7.1.TIF CONSTRPLANS VIEW
012__A7.2.TIF CONSTRPLANS VIEW
013__A7.3.TIF CONSTRPLANS VIEW
014__A7.4.TIF CONSTRPLANS VIEW
015__A7.5.TIF CONSTRPLANS VIEW
016__A7.6.TIF CONSTRPLANS VIEW
017__MP1.1.TIF CONSTRPLANS VIEW
018__MP1.2.TIF CONSTRPLANS VIEW
019__MP1.3.TIF CONSTRPLANS VIEW
020__MP2.0.TIF CONSTRPLANS VIEW
021__MP2.1.TIF CONSTRPLANS VIEW
022__MP3.0.TIF CONSTRPLANS VIEW
023__MP4.0.TIF CONSTRPLANS VIEW
024__E1.0.TIF CONSTRPLANS VIEW
025__E1.1.TIF CONSTRPLANS VIEW
026__E1.2.TIF CONSTRPLANS VIEW
027__E1.3.TIF CONSTRPLANS VIEW
E1.0.TIF CONSTRPLANS VIEW
E1.2.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW