Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
Final
Type:
COMMERCIAL NEW
Apply Date:
03/28/2008
Applicant:
WITMER, GALLAGHER
Description:
NEW SHELL BLDG
Contractors:
  • TL ROOF AND ASSOCIATES

Permit Reviews

Permit Number - T08CM01024
Permit Status: Final
Permit Description: NEW SHELL BLDG
Start Date Submittal Complete Date Status  
02/02/2011 REVISION - - 4TH 02/02/2011 COMPLETED Review Details
02/02/2011 REVISION - - 4TH 03/30/2011 COMPLETED Review Details
03/28/2008 PLANS OK TO SUBMIT - 3RD PARTY 03/28/2008 COMPLETED Review Details
03/28/2008 3RD PARTY REVIEW-COMMERCIAL 05/02/2008 COMPLETED Review Details
05/02/2008 POST 3RD PARTY REVIEW 05/13/2008 COMPLETED Review Details
05/11/2011 REVISION - - 5TH 05/12/2011 COMPLETED Review Details
05/12/2009 3RD PARTY REVIEW-REVISION/OTHER 05/26/2009 COMPLETED Review Details
05/20/2009 REVISION - - 1ST 05/26/2009 COMPLETED Review Details
06/11/2010 REVISION - - 2ND 06/11/2010 COMPLETED Review Details
06/23/2008 3RD PARTY REVIEW-REVISION/OTHER 06/23/2008 COMPLETED Review Details
09/19/2008 3RD PARTY REVIEW-REVISION/OTHER 09/23/2008 COMPLETED Review Details
10/30/2008 3RD PARTY REVIEW-REVISION/OTHER 10/31/2008 COMPLETED Review Details
11/04/2008 3RD PARTY REVIEW-REVISION/OTHER 11/10/2008 COMPLETED Review Details
11/28/2008 3RD PARTY REVIEW-REVISION/OTHER 12/08/2008 COMPLETED Review Details
12/21/2010 REVISION - - 3RD 01/31/2011 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T08CM01024
Permit Status: Final
Permit Description: NEW SHELL BLDG
Total Outstanding Activity Conditions - 1
Date Name
03/28/2008 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T08CM01024
Permit Description: NEW SHELL BLDG
Total Completed Inspections - 46
Date Description Inspector Results Comments
06/25/2008 ELECTRIC - UFER LHANLY Approved IVRS - Inspection :*
3/0 CU CLAMPED TO 20' REBAR

RELOCATED TO BETWEEN GRIDLINE 6 & 7 ON WEST SIDE
OF BUILDING PER NOT YET APPROVED REVISION
07/02/2008 EXCAVATION/LAYOUT REBAR & ZON MHENSON Approved IVRS - Inspection :*
OK TO POUR DUMPSTER FOOTINGS WITH SPECIAL
07/23/2008 ELECTRIC - UNDERGROUND DSANTACR Approved IVRS - Inspection :*
OK U.G POWER & DATA TO PHONE ROOM AND TO SWITCH GEAR AREA, FROM SUITE AREA
08/26/2008 PLUMBING - YARD WTR LINE/TEST RLEDONNE Approved IVRS - Inspection :*
1. YARD WATER PER HIGHLIGHT ON PAGE P-1
2. TEST ON ROOF DRAIN STUB UP AT BUILD AND 5' FROM BUILDING TEST OK
10/01/2008 BUILDING PRE-SLAB MHENSON Approved IVRS - Inspection :*
NEED PLUMBING PRE-SLAB
10/02/2008 PLUMBING - PRE SLAB RMYERS Approved IVRS - Inspection :*
PUBLIC RESTROOMS AND ADJOINING MECHANICAL ROOM
OK FOR CONCRETE S.T.O.I
10/07/2008 SITE - SEWER RLEDONNE Approved IVRS - Inspection :*
11/04/2008 EXT METAL CLIPS/EXT SHEATHING AQUIROZ Approved IVRS - Inspection :*
VENDOR SHED OK
11/12/2008 PLUMBING - ROUGH, SOIL RLEDONNE Approved IVRS - Inspection :*
NEW 2" GREASE WASTE AND 3" WASTE #113 VENDOR
AND #112 - 3" NEW WASTE TEST OK
11/13/2008 REINFORCED MASONRY PRE-GROUT MHENSON Approved IVRS - Inspection :*
1. RM. 103 TOP OUT AND 102 GABLE ENDS DETAIL SK33
2. NEED DOCUMENTATION FROM SPECIAL INSPECTOR FOR GABLE ENDS RM. 102
11/14/2008 STUCCO MESH MHENSON Approved IVRS - Inspection :*
WEST EXTERIOR WALL GABLE END AND SERVICE ENTRY
OK TO STUCCO
12/01/2008 FRAMING MHENSON Approved IVRS - Inspection :*
PARTIAL - BATHROOMS
12/09/2008 STEM WALL/RETAINING WALL MHENSON Approved IVRS - Inspection :*
1. D-3 TO 7
7-D TO E
STOREFRONT STEM WALL
2. ADDED STOREFRONT NOT ON PLAN
3. NEED REVISED PLANS FOR STOREFRONT
12/19/2008 ROOF NAILING MHENSON Approved IVRS - Inspection :*
RM. 102, 103B OK TO DRY IN
06/16/2010 ELECTRIC - ABOVE CEILING RHOLLAND Approved IVRS - Inspection :*
06/21/2010 PLUMBING - INTERMEDIATE RLEDONNE Approved IVRS - Inspection :*
1) FLUSH VALVES FOR WATER CLOSETS IN WALLS OK
06/25/2010 BUILDING - FINAL MHENSON Approved IVRS - Inspection :*
1) RESTROOMS NEED TO BE ACCESSIBLE
07/08/2010 ELECTRIC - INTERMEDIATE RHOLLAND Approved IVRS - Inspection :*
1) SUPPORT CONDUITS ABOVE PANEL "HP-2"
2) INSTALL ARC FLASH LABELS
3) SUPPORT CONDUITS WITHIN 2' OF PANELS AND SERVICE
4) NEED LOCK NUT OR METAL BUSHING TO SECURE FITTING AT PANEL HP
5) FINISH PAD UNDER SES
6) NEED PLAN REVISION FOR PANLE 'PV'-BEING FED FOR 80 AMPS, PLAN CALLS FOR 60 AMPS
7) NOTE: 408.4 WILL APPLY
8) NEED ADDRESS LABEL OUTSIDE OF SERVICE
9) RECEIVED LETTERS FOR NM CABLE AND TORQUE
07/08/2010 ELECTRIC - TEMPORARY SERVICE RHOLLAND Approved IVRS - Inspection :*
07/08/2010 ELECTRIC - CABLE DROP RHOLLAND Approved IVRS - Inspection :*
07/09/2010 TEP CLEARANCE - AM JWEATHER Approved TMPP CLEARED FOR 'HOUSE PANEL' PER R. HOLLANDER-2ND TIME SENT TO TEP
09/01/2010 FIRE - FINAL LThomas Approved Approved 9/1/10
12/15/2010 PLUMBING - FINAL RLEDONNE Approved IVRS - Inspection :*
1) GAS PIPING TO #DH1 AND VH#1 & 2 PSI TEST OK (ONLY)
12/15/2010 MECHANICAL - ABOVE CEILING MRAMBER Approved IVRS - Inspection :*
12/15/2010 MECHANICAL - INTERMEDIATE MRAMBER Approved IVRS - Inspection :*
12/16/2010 MECHANICAL - FINAL MRAMBER Approved IVRS - Inspection :*
1) FLUE PIPING AT RESTROOMS OK
01/31/2011 FIRE SPKLR - FINAL LTHOMAS Approved
01/31/2011 FIRE SPKLR - UG PIPING FLUSH LTHOMAS Approved
01/31/2011 FIRE SPKLR - OH PIPING & HYDRO LTHOMAS Approved
01/31/2011 FIRE SPKLR - UG, PIPING, HYDRO LTHOMAS Approved
01/31/2011 BUILDING ABOVE CEILING MHENSON Approved IVRS - Inspection :*
04/05/2011 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
04/25/2011 PLUMBING - GAS PRESS TEST FNL RRICH Approved IVRS - Inspection :*
04/25/2011 PLUMBING - GAS PRESSURE TEST RRICH Approved IVRS - Inspection :*
04/25/2011 PLUMBING - BACK WATER VALVE RRICH Approved IVRS - Inspection :*
04/25/2011 PLUMBING - SEWER HCS CONNECT RRICH Approved IVRS - Inspection :*
05/09/2011 SIGN - FINAL JYBARRA Approved IVRS - Inspection :* C/O ONLY
05/09/2011 NPPO - FINAL JFEMLING Approved Approved
05/09/2011 LANDSCAPE - FINAL JFEMLING Approved Approved
05/09/2011 RIGHT OF WAY - FINAL M.Otero Approved
05/10/2011 OUTDOOR LIGHTING FINAL DSANTACR Approved IVRS - Inspection :*
05/10/2011 ELECTRIC - OUTDOOR LIGHTING DSANTACR Approved IVRS - Inspection :*
05/10/2011 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection :*
05/10/2011 ENGINEERING - FINAL JFEMLING Approved Remove roll off dumpster, potta john and construction materials prior to last TI C of O for this shell.
05/11/2011 PERMIT FINALED JWEATHER Approved
05/11/2011 U VALUE FOR WINDOW LHANLY Approved