Permit Reviews
Permit Number - T08CM00671
Permit Status: C of o
Permit Description: NEW MUSEUM
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/27/2008 | PLANS OK TO SUBMIT - 3RD PARTY | 02/27/2008 | COMPLETED |
| 02/27/2008 | 3RD PARTY REVIEW-COMMERCIAL | 04/11/2008 | COMPLETED |
| 03/05/2009 | 3RD PARTY REVIEW-REVISION/OTHER | 03/12/2009 | COMPLETED |
| 04/11/2008 | POST 3RD PARTY REVIEW | 04/29/2008 | COMPLETED |
| 09/03/2008 | 3RD PARTY REVIEW-REVISION/OTHER | 09/03/2008 | COMPLETED |
| 11/25/2008 | 3RD PARTY REVIEW-REVISION/OTHER | 12/03/2008 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T08CM00671
Permit Status: C of o
Permit Description: NEW MUSEUM
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 02/27/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T08CM00671
Permit Description: NEW MUSEUM
Total Completed Inspections - 41
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/07/2008 | EXCAVATION/LAYOUT REBAR & ZON | JBURGE | Approved | IVRS - Inspection :* 7 AT F2/C3 FOOTINGS LINE A/3.1 TO A/4.1; A.1/3.1-OK TO POUR FOOTINGS |
| 08/25/2008 | ROOF NAILING | JBURGE | Approved | IVRS - Inspection :* CRICKETS & PARAPET WALLS COMPLETE -- OK TO DRY IN |
| 08/27/2008 | EXT METAL CLIPS/EXT SHEATHING | JBURGE | Approved | IVRS - Inspection :* PORCH CANOPIES COMPLETE |
| 10/17/2008 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection :* ADDITION OF 3" CLEANOUT AT P-4, INSULATION IN WALL, SECURING OF REVENT IN GANG RESTROOM OK |
| 10/20/2008 | PLUMBING - ROOF DRAINS | RRICH | Approved | IVRS - Inspection :* |
| 10/23/2008 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection :* 1. CONTRACTOR TO ADD HANGERS AS REQUIRED 2. LOW PRESSURE TEST OK ON NON-WELDED PIPE |
| 11/07/2008 | REINFORCED MASONRY PRE-GROUT | JBURGE | Approved | 16 @ LIGHT POLE CAISSON FOOTINGS OK TO POUR AS PER DETAIL #30; PAGE S1.3 |
| 11/13/2008 | ELECTRIC - OUTDOOR LIGHTING | RJIROUDE | Approved | IVRS - Inspection :* OK U.G FOR POLE LIGHTS AS INDICATED ON PLANS E 0.0 |
| 11/25/2008 | ELECTRIC - CABLE DROP | RMORENO | Approved | IVRS - Inspection :* NEED BOND |
| 12/02/2008 | ELECTRIC - UNDERGROUND | RMORENO | Approved | IVRS - Inspection :* SECONDARYs 6 - 2", 1 - 4" PHONE FROM BUILDING TO TRANSFORMER OK PHONE FROM POLE TO PEDESTAL OK |
| 12/02/2008 | FRAMING | JBURGE | Approved | EXTERIOR COLUMNS (WING WALLS) |
| 12/09/2008 | ELECTRIC - INTERMEDIATE | RMORENO | Approved | IVRS - Inspection :* NORTHWEST ENTRANCE CAN LIGHTS OK GIFT SHOP CAN LIGHTS OK FRONT ENTRY WAY CAN LIGHTS OK BATHROOM BOTH LIGHTS OK FOYER CAN LIGHTS OK |
| 12/09/2008 | SHEET ROCK NAILING | JBURGE | Approved | IVRS - Inspection :* INTERIOR WALLS (NO CEILINGS) LINES C/6 - C.2/6; LIGHTING CLOSET #115B; WING WALLS @ MAIN ENTRY 1/2 PLYWOOD SHEETING |
| 12/10/2008 | STUCCO MESH | JBURGE | Approved | IVRS - Inspection :* ROOF PARAPET WALLS -- OK TO STUCCO |
| 12/30/2008 | PLUMBING - YARD WTR LINE/TEST | BBENEDON | Approved | IVRS - Inspection :* 1) YARD LINE FROM METER THRU RP TO BLDG IS SCHEDULE 40 PVC. SPEC BOOK 15100 2.04 C SPECIFIES CLASS 200 OR 14 PVC. 100 PSI TEST IS OK REDLINE LOCATION RP, PROVIDE SUPPORT PER TUCSON WATER DETAIL RECALL FOR INSPECTION OF BLDG CONNECTION |
| 12/31/2008 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection :* 1) REQUIRE GREEN TRACER WIRE FOR SEWER PIPING 2) CONTRACTOR TO INSTALL CORRECT WIRE, THEN OK TO COVER |
| 02/13/2009 | TEP CLEARANCE - PM | JWEATHER | Approved | ECO CLEARED PER R. MORENO |
| 02/18/2009 | PLUMBING - GAS PRESS TEST FNL | BBENEDON | Approved | IVRS - Inspection :* |
| 02/27/2009 | PLUMBING - ABOVE CEILING | BBENEDON | Approved | IVRS - Inspection :* |
| 03/02/2009 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* OK FOR CEILING TILES |
| 04/17/2009 | PLUMBING - FINAL | BBENEDON | Approved | IVRS - Inspection :* |
| 04/20/2009 | PLUMBING - BACK WATER VALVE | BBENEDON | Approved | |
| 04/20/2009 | SITE - SEWER | BBENEDON | Approved | |
| 04/28/2009 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
| 04/28/2009 | FIRE - FINAL | LTHOMAS | Approved | |
| 05/07/2009 | ELECTRIC - FINAL | RMORENO | Approved | IVRS - Inspection :* |
| 05/07/2009 | RIGHT OF WAY - FINAL | PWHIDDON | Approved | PER EMAIL |
| 05/08/2009 | OUTDOOR LIGHTING FINAL | RMORENO | Approved | |
| 05/08/2009 | ELECTRIC - ABOVE CEILING | RMORENO | Approved | |
| 05/08/2009 | ELECTRIC - TEMP POWER FOR TEST | RMORENO | Approved | |
| 05/12/2009 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
| 05/12/2009 | NPPO - FINAL | ACONNOR | Approved | |
| 05/18/2009 | U VALUE FOR WINDOW | JBURGE | Approved | IVRS - Inspection :* |
| 05/18/2009 | BUILDING ABOVE CEILING | JBURGE | Approved | IVRS - Inspection :* |
| 05/21/2009 | LANDSCAPE - FINAL | ACONNOR | Approved | |
| 05/21/2009 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | |
| 06/03/2009 | ENGINEERING - FINAL | MRUSSO | Approved | |
| 06/22/2009 | BUILDING - FINAL | JBURGE | Approved | IVRS - Inspection :* TRADES AND FIRE FINALS ARE COMPLETE |
| 07/08/2009 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* 1) OK FOR FINAL 2) DUCT SMOKE DETECTORS OK |
| 07/08/2009 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | |
| 07/09/2009 | PERMIT FINALED | JWEATHER | Approved |