Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/07/2008 | REINFORCED MASONRY PRE-GROUT | Approved | 16 @ LIGHT POLE CAISSON FOOTINGS OK TO POUR AS PER DETAIL #30; PAGE S1.3 |
|
| 08/27/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | ||
| 08/25/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* WEST SCREEN WALL @ 4' |
|
| 08/08/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EXTERIOR PERIMETER WALLS: LINES @ B/3 TO C.2/7 @ 20' TO 24'8" -- OK TO GROUT PROGRESS AREAS |
|
| 08/07/2008 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* WILL RECALL |
|
| 08/05/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NORTH WALL INTERIOR & EXTERIOR LINE A/4.1 TO B.2/1 B.2/1 TO D/1 @ 12'-16'; SOUTH WALL D/1 TO D.5/4.1 @ 16'-20' OK TO GROUT PROGRESS AREAS |
|
| 08/04/2008 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
| 07/30/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* CMU PERIMETER WALLS - NORTH, EAST, WEST @ 16' SOUTH WALL @ 20' -- OK TO GROUT PROGRESS AREAS |
|
| 07/25/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SOUTH & EAST & NE CMU WALLS - LINES B/6.1 TO E/5.1 @ 12' - 16' - OK TO GROUT SOUTH WING WALLS (4) @ 8' - 12' OK TO GROUT |
|
| 07/23/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* WEST WALL - LINE B.1/1 TO D/1 @ 8' TO 12' SOUTH WALL LINE D/1 TO D.75/4.1 @ 12' TO 16' OK TO GROUT |
|
| 07/21/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 12' ALL BUT LINE 1 AND LINTEL @ A/3.1-4.1 OK TOP OF POPOUT N OF LINE A OK |
|
| 07/17/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* CMU WALLS @ 8'-12' LINES C.5/1 TO D/1 D/1 TO E.75/7; E.75/7 TO C.2/7: INTERIOR & EXTERIOR WALLS @ 4'-8'; LINES B.3/1 TO B.3/3, B.3/3 TO B/3, B/3 TO B/1.5 OK TO GROUT PROGRESS AREAS |
|
| 07/15/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EXTERIOR CMU WALLS @ 4' TO 8' - LINES B-1/3 TO D.5/7 OK TO GROUT LINE D.5/7 TO E/5.1; 4' TO 8' GROUTED; WING WALLS @ 4' LINE E/5.1 TO D.5/3.1; GROUTED |
|
| 07/11/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SOUTH WALL LINE 1/D TO 5.1/D @ 4' TO 8' OK TO GROUT |
|
| 07/08/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* CONTINUOUS CMU WALLS @ 48" OK TO GROUT PROGRESS AREAS |