Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL NEW
Address:
4500 N ORACLE RD
Address NEW:
4500 N ORACLE RD
Apply Date:
02/14/2008
Applicant:
METRO PERMIT EXPRESS, INC *C
Description:
NEW PARKING GARAGE
Contractors:
  • LEDCOR CONSTRUCTION INC

Permit Reviews

Permit Number - T08CM00514
Permit Status: C of o
Permit Description: NEW PARKING GARAGE
Start Date Submittal Complete Date Status  
02/14/2008 PLANS OK TO SUBMIT - 3RD PARTY 03/05/2008 COMPLETED Review Details
03/05/2008 3RD PARTY REVIEW-COMMERCIAL 05/01/2008 COMPLETED Review Details
05/01/2008 POST 3RD PARTY REVIEW 05/30/2008 COMPLETED Review Details
05/30/2008 RESUBMITTAL 05/30/2008 COMPLETED Review Details
09/08/2008 3RD PARTY REVIEW-REVISION/OTHER 09/11/2008 COMPLETED Review Details
09/15/2008 3RD PARTY REVIEW-REVISION/OTHER-2ND 10/20/2008 COMPLETED Review Details
10/15/2009 REVISION - - 1ST 10/15/2009 COMPLETED Review Details
10/24/2008 3RD PARTY REVIEW-REVISION/OTHER 10/24/2008 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T08CM00514
Permit Status: C of o
Permit Description: NEW PARKING GARAGE
Total Outstanding Activity Conditions - 1
Date Name
02/14/2008 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T08CM00514
Permit Description: NEW PARKING GARAGE
Total Completed Inspections - 33
Date Description Inspector Results Comments
10/11/2008 STEM WALL/RETAINING WALL AQUIROZ Approved IVRS - Inspection :*
50' WEST OF G.L 1.0/A.0-0A
10/15/2008 ELECTRIC - UNDERGROUND RHOLLAND Approved IVRS - Inspection :*
OK 7-3/4", 1 - 1", 1 - 1 1/4" PVC CONDUITS
SOUTH & WEST HALF
10/30/2008 EXCAVATION/LAYOUT REBAR & ZON LHANLY Approved IVRS - Inspection :*
10/31/2008 BUILDING PRE-SLAB GDABBS Approved IVRS - Inspection :*
PEDESTRIAN BRIDGE FLOOR REINFORCMENT STEEL

OK TO PLACE WHAT SPECIAL INSP. APPROVES
11/05/2008 REINFORCED MASONRY PRE-GROUT AQUIROZ Approved 1ST LIFT OK
11/18/2008 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection :*
BLDG. DRAIN TO BLDG. SEWER CONNECTION MADE OK
11/20/2008 BUILDING - PROGRESS AQUIROZ Approved IVRS - Inspection :*
CANCELED
11/20/2008 PLUMBING - PROGRESS BBENEDON Approved IVRS - Inspection :*
12/18/2008 ELECTRIC - INTERMEDIATE RHOLLAND Approved IVRS - Inspection :*
1) PLEASE VERIFY RESISTANCE OF GROUNDING ELECTRODE PER 250.56
12/19/2008 TEP CLEARANCE - AM JWEATHER Approved TMPP CLEARED PER R. HOLLANDER
09/16/2009 OUTDOOR LIGHTING FINAL DSANTACR Approved
09/16/2009 ELECTRIC - PROGRESS DSANTACR Approved
09/16/2009 ELECTRIC - UFER DSANTACR Approved
09/16/2009 ELECTRIC - OUTDOOR LIGHTING DSANTACR Approved
09/16/2009 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection :*
09/24/2009 PLUMBING - ROUGH, SOIL RMYERS Approved
09/24/2009 PLUMBING - PRE SLAB RMYERS Approved
09/24/2009 PLUMBING - ROOF DRAINS RMYERS Approved
09/24/2009 PLUMBING - YARD WTR LINE/TEST RMYERS Approved
09/24/2009 PLUMBING - BACK WATER VALVE RMYERS Approved
09/24/2009 PLUMBING - FINAL RMYERS Approved 1) HANGERS TO BE INSTALLED WITHIN 18" EACH SIDE OF THE COUPLING
2) EXTEND VENT AT ELEVATOR SHAFT TO ABOVE PARAPET
3) HANGER MAY NOT BE INSTALLED ON COUPLING
4) RAISE CLEANOUTS HALF BURRIED IN ASPHALT
5) FLASH SYSTEM AND BREAK OFF RETAINING SCREW AT HOSE BIBBS
6) PROVIDE BACKFLOW CERT FOR RPPBP
10/05/2009 RIGHT OF WAY - FINAL MOTERO Approved PER EMAIL
10/05/2009 MECHANICAL - INTERMEDIATE MRAMBER Approved
10/05/2009 MECHANICAL - PROGRESS MRAMBER Approved
10/05/2009 MECHANICAL - FINAL MRAMBER Approved IVRS - Inspection :*
10/05/2009 SIGN - FINAL JYBARRA Approved
10/06/2009 FIRE - FINAL LTHOMAS Approved
10/06/2009 FIRE - ALARM FINAL LTHOMAS Approved
10/06/2009 FIRE SPKLR - OH PIPING & HYDRO LTHOMAS Approved
12/02/2009 ENGINEERING - FINAL MRUSSO Approved
12/29/2009 BUILDING - FINAL AQUIROZ Approved IVRS - Inspection :*
02/04/2010 NPPO - FINAL ACONNOR Approved
02/04/2010 LANDSCAPE - FINAL ACONNOR Approved