Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T08CM00514

Parcel: 10511061R


Addresses:

4500 N ORACLE RD


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T08CM00514

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
09/24/2009 PLUMBING - FINAL Approved 1) HANGERS TO BE INSTALLED WITHIN 18" EACH SIDE OF THE COUPLING
2) EXTEND VENT AT ELEVATOR SHAFT TO ABOVE PARAPET
3) HANGER MAY NOT BE INSTALLED ON COUPLING
4) RAISE CLEANOUTS HALF BURRIED IN ASPHALT
5) FLASH SYSTEM AND BREAK OFF RETAINING SCREW AT HOSE BIBBS
6) PROVIDE BACKFLOW CERT FOR RPPBP
09/23/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PLEASE CALL IN AND HAVE APPROVED ALL REQUIRED INSPECTIONS PRIOT TO CALLING FINAL