Permit: T07CM03772
Permit Details
Apply Date:
09/18/2007
Applicant:
NICOLE LEE
Description:
TI:CIRCLE K STORE # 1449 R1 - Plumbing relocate
Permit Reviews
Permit Number - T07CM03772
Permit Status: Final
Permit Description: TI:CIRCLE K STORE # 1449
R1 - Plumbing relocate
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/04/2008 | REVISION - - 1ST | 02/04/2008 | COMPLETED |
| 09/18/2007 | COMMERCIAL TI | 09/25/2007 | COMPLETED |
| 09/25/2007 | RESUBMITTAL | 09/25/2007 | COMPLETED |
| 09/25/2007 | RESUBMITTAL | 12/20/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM03772
Permit Status: Final
Permit Description: TI:CIRCLE K STORE # 1449
R1 - Plumbing relocate
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/18/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T07CM03772
Permit Description: TI:CIRCLE K STORE # 1449
R1 - Plumbing relocate
Total Completed Inspections - 21
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/28/2007 | ELECTRIC - INTERMEDIATE | RJIROUDE | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1. NOT PER PLANS. PLANS SHOWS 400 AMP BUSHING IN WIREWAY AND THIS BUSHING DOES NOT EXIST. CANNOT JUST TAP ONE CONDUCTOR OF PARALLEL FEED TO EXISTING SERVICE 2. INSTALL MAIN BONDING JUMPER AT NEW SERVICE PANELS 3. PLEASE VERIFY GROUNDING ELECTRODE SYSTEM FOR BUILDING |
| 01/18/2008 | MECHANICAL - ABOVE CEILING | MRAMBER | Approved | |
| 01/18/2008 | MECHANICAL - FINAL | MRAMBER | Approved | IVRS - Inspection :* |
| 01/18/2008 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED PER D. SANTACRUZ |
| 02/05/2008 | PLUMBING - ROUGH, SOIL | BBENEDON | Approved | IVRS - Inspection :* HAND SINKS AND FS PIPING W/TEST THRU ROOF OK TO COVER. WATER PIPING IN WALLS AT THESE LOCATIONS OK. TIE IN TO EXISTING OK |
| 02/15/2008 | SHEET ROCK NAILING | MHENSON | Approved | IVRS - Inspection :* |
| 02/21/2008 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved | IVRS - Inspection :* |
| 02/21/2008 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection :* |
| 02/28/2008 | PLUMBING - FINAL | BBENEDON | Approved | IVRS - Inspection :* |
| 02/28/2008 | PLUMBING - PROGRESS | BBENEDON | Approved | IVRS - Inspection :* |
| 02/28/2008 | PLUMBING - INTERMEDIATE | BBENEDON | Approved | IVRS - Inspection :* |
| 03/19/2008 | NPPO - FINAL | ACONNOR | Approved | N/A |
| 03/19/2008 | LANDSCAPE - FINAL | ACONNOR | Approved | N/A |
| 03/19/2008 | FIRE - FINAL | LTHOMAS | Approved | |
| 03/19/2008 | SIGN - FINAL | JYBARRA | Approved | |
| 03/21/2008 | ENGINEERING - FINAL | MAVERY | Approved | |
| 03/21/2008 | RIGHT OF WAY - FINAL | LLOPEZ | Approved | PER EMAIL |
| 04/17/2008 | FRAMING | MHENSON | Approved | IVRS - Inspection :* |
| 05/05/2008 | BUILDING - PROGRESS | MHENSON | Approved | IVRS - Inspection :* |
| 05/05/2008 | BUILDING - FINAL | MHENSON | Approved | IVRS - Inspection :* |
| 05/06/2008 | PERMIT FINALED | BFLORES | Approved |