Permit: T07CM03772

Parcel: 130053040


Addresses:

1909 E 36TH ST

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
02/05/2008 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
HAND SINKS AND FS PIPING W/TEST THRU ROOF
OK TO COVER. WATER PIPING IN WALLS AT THESE
LOCATIONS OK. TIE IN TO EXISTING OK
02/04/2008 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1) PROVIDE APPROVED PLANS
2) PROVIDE A SWEEP ON HS TRAP ARM
3) WIPE OFF EXCESS FLUX FROM SOLDIER JOINTS
4) SECURE/CLAMP VEN T IN WALL
5) WRAP PIPING PASSING THRU CONCRETE WITH FOAM
6) FRANK PATTERN CO COVER REQUIRED AT FCO
01/29/2008 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
CANCELED