Permit: T07CM03771
Permit Details
Status:
Expired
Type:
COMMERCIAL ALTERATION
Address:
2351 N ALVERNON WY
Address NEW:
2351 N ALVERNON WY
Apply Date:
09/18/2007
Applicant:
NICOLE LEE
Description:
TI:CIRCLE K STORE #1582
Contractors:
- ARIZONA COMMERCIAL BUILDERS INC
Permit Reviews
Permit Number - T07CM03771
Permit Status: Expired
Permit Description: TI:CIRCLE K STORE #1582
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/18/2007 | COMMERCIAL TI | 09/25/2007 | COMPLETED |
| 09/25/2007 | RESUBMITTAL | 09/25/2007 | COMPLETED |
| 09/25/2007 | RESUBMITTAL | 12/03/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM03771
Permit Status: Expired
Permit Description: TI:CIRCLE K STORE #1582
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/18/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Expired
Permit Number: T07CM03771
Permit Description: TI:CIRCLE K STORE #1582
Total Completed Inspections - 14
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/19/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | INCR CLEARED PER C. CLEMENS |
| 12/27/2007 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* 1) ABS DWV UNDERGROUND OK TO COVER 2) WATER TEST TO TEN FEET OK 3) ABS AND COPPER IN WALL TO ABOVE CEILING OK TO COVER |
| 12/28/2007 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :* 1. VERTICAL TO HORIZONTAL CHANGE OF DIRECTION TO BE A WYE BRANCH FITTING OR EQUIVALENT SWEEP. NO CORRECTIONS REQUIRED AT THIS TIME 2. REMOVE RAISED SQUARE HEAD PLUG AND INSTALL COUNTER SUNK TAPPED CLEANOUT PLUG WITH MACHINE SCREW INDIRECT WASTE PIPING INSTALLED OK |
| 12/28/2007 | ELECTRIC - INTERMEDIATE | CCLEMENS | Approved | IVRS - Inspection :* |
| 01/10/2008 | PLUMBING - PROGRESS | RMYERS | Approved | IVRS - Inspection :* INSTALL ATMOSPHERIC VACUUM BREAKER ON EXTERIOR HOSE BIBB - A TRAP ARM MAY NOT CHANGE SIZE - A TRAP AND TRAP ARM TO BE THE SAME SIZE - TRAP MAY BE ONLY ONE PIPE SIZE LARGER THAN THE TAILPIECE TO WHICH IT IS CONNECTED. |
| 01/10/2008 | FRAMING | JBURGE | Approved | IVRS - Inspection :* PONY WALL ABOVE BEER CAVE - FRAMED AND TAPED |
| 02/05/2008 | MECHANICAL - ABOVE CEILING | MRAMBER | Approved | IVRS - Inspection :* |
| 02/05/2008 | MECHANICAL - FINAL | MRAMBER | Approved | IVRS - Inspection :* |
| 02/12/2008 | ELECTRIC - FINAL | CCLEMENS | Approved | IVRS - Inspection :* |
| 02/12/2008 | ELECTRIC - ABOVE CEILING | CCLEMENS | Approved | IVRS - Inspection :* |
| 05/14/2008 | FIRE - FINAL | LTHOMAS | Approved | |
| 05/22/2008 | BUILDING - FINAL | JBURGE | Approved | IVRS - Inspection :* 1) PENDING PLUMBING FINAL |
| 05/22/2008 | BUILDING - PROGRESS | JBURGE | Approved | IVRS - Inspection :* |
| 06/11/2008 | PLUMBING - FINAL | RMYERS | Approved |