Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - PROGRESS
Permit Number - T07CM03771
Inspection Description - PLUMBING - PROGRESS
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/10/2008 | PLUMBING - PROGRESS | Approved | IVRS - Inspection :* INSTALL ATMOSPHERIC VACUUM BREAKER ON EXTERIOR HOSE BIBB - A TRAP ARM MAY NOT CHANGE SIZE - A TRAP AND TRAP ARM TO BE THE SAME SIZE - TRAP MAY BE ONLY ONE PIPE SIZE LARGER THAN THE TAILPIECE TO WHICH IT IS CONNECTED. |
|
01/09/2008 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* 1. AT HANDSINK: FEMALE ABS THREADS MAY NOT BE INSTALLED IN AN UNACCESSIBLE LOCATION 2. WATER HEATER WILL REQUIRE AN EXPANSION TANK FOR FINAL 3. ALL EXISTING INDIRECT WASTE PIPING TO HAVE SLOPE AND BE MADE SANITARY (1" AIR GAP) 4. ALL NEW I.W PIPING TO BE OF APPROVED MATERIAL TYPE INSTALLED WITH SLOPE TO A 1" AIR GAP 5. ONLY ONE SLIP NUT ON THE OUTLET SIDE OF A TRAP AT NEW SINK AND REMOVE CLEANOUT COVER FOR SINK FOR INSPECTION. |