Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
COMMERCIAL OTHER
Address:
4500 N ORACLE RD
Address NEW:
4500 N ORACLE RD
Apply Date:
12/17/2007
Applicant:
METRO PERMIT EXPRESS, INC *C
Description:
CUT FILL
Contractors:
  • LEDCOR CONSTRUCTION INC

Permit Reviews

Permit Number - T07BU02606
Permit Status: Final
Permit Description: CUT FILL
Start Date Submittal Complete Date Status  
07/17/2009 REVISION - GRADING 07/17/2009 COMPLETED Review Details
08/14/2009 REVISION - GRADING 08/24/2009 COMPLETED Review Details
10/20/2008 REVISION - GRADING 10/20/2008 COMPLETED Review Details
12/17/2007 PLANS OK TO SUBMIT - GRADING 12/17/2007 COMPLETED Review Details
12/21/2007 GRADING 05/27/2008 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T07BU02606
Permit Status: Final
Permit Description: CUT FILL
Total Outstanding Activity Conditions - 1
Date Name
12/17/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T07BU02606
Permit Description: CUT FILL
Total Completed Inspections - 9
Date Description Inspector Results Comments
02/14/2008 ENGINEERING PRE-CONSTRUCTION MRUSSO Approved 1) TWO EXISTING CATCH BASINS ON SITE - TWO LAYERS OF SILT SOCK W/SANDBAGS AROUND EACH - CONTINUE TO MAINTAIN AND REPLACE IF NECESSARY.
2) SILT SOCK INSTALLED ALONG PERIMETER FENCE AT SOUTH SIDE OF SITE - ENSURE SOCK OVERLAPS AND IS SECURED IN PLACE, MAINTAIN AS NECESSARY.
3) GRAVEL BAGS INSTALLED AT SURFACE DRAINAGE OUTLET ALONG SOUTH SIDE.
4) SWEEP UP ANY TRACKED SOIL ROUTINELY - ENSURE SEDIMENT STAYS ON SITE. MAY NEED STABILIZED CONSTRUCTION ENTRANCE/EXIT.
5) INSTALL A DESIGNATED CONCRETE WASH OUT WHEN APPLICABLE.
02/28/2008 STORMWATER INSTALL OF CONTROLS MRUSSO Approved
10/15/2009 GRADING - FINAL JFEMLING Approved Site not ready
12/30/2009 GRADING - INTERMEDIATE MRUSSO Approved NO SIGNIFICANT STORM WATER CONCERNS AT THIS TIME.
NO CHANGES, SITE WORK AND BLDG UNDER CONSTRUCTION
12/30/2009 STORMWATER FOLLOW-UP INSP MRUSSO Approved NO SIGNIFICANT STORM WATER CONCERNS AT THIS TIME.
NO CHANGES, SITE WORK AND BLDG UNDER CONSTRUCTION
04/08/2010 GRADING - CHECK FOR ACTIVITY MRUSSO Approved
08/19/2010 PLUMBING - ROOF DRAINS JFEMLING Approved final under T07CM04291
08/19/2010 PLUMBING - FINAL JFEMLING Approved final under T07CM04291
08/19/2010 PLUMBING - INTERMEDIATE JFEMLING Approved final under T07CM04291