Permit: T06CM05102
Permit Details
Apply Date:
09/20/2006
Applicant:
CAYLOR CONSTRUCTION COMPANY , RO
Description:
NEW MEDICAL OFFICE
Contractors:
- CAYLOR CONSTRUCTION COMPANY , RO
Permit Reviews
Permit Number - T06CM05102
Permit Status: C of o
Permit Description: NEW MEDICAL OFFICE
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/12/2007 | POST 3RD PARTY REVIEW | 02/01/2007 | COMPLETED |
02/01/2007 | POST 3RD PARTY REVIEW | 02/05/2007 | COMPLETED |
06/18/2007 | 3RD PARTY REVIEW-REVISION/OTHER | 06/18/2007 | COMPLETED |
08/09/2007 | 3RD PARTY REVIEW-REVISION/OTHER-2ND | 08/13/2007 | COMPLETED |
09/20/2006 | PLANS OK TO SUBMIT - COMM | 09/22/2006 | COMPLETED |
09/22/2006 | 3RD PARTY REVIEW-COMMERCIAL | 01/12/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM05102
Permit Status: C of o
Permit Description: NEW MEDICAL OFFICE
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
09/20/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T06CM05102
Permit Description: NEW MEDICAL OFFICE
Total Completed Inspections - 43
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/13/2007 | STEM WALL/RETAINING WALL | JBURGE | Approved | SOUTHWALL @ 16" OK TO POUR |
03/28/2007 | ELECTRIC - UFER | CCLEMENS | Approved | |
05/01/2007 | FIRE SPKLR - FINAL | LTHOMAS | Approved | Need plan and permit for underground |
06/26/2007 | ELECTRIC - TEMPORARY SERVICE | CCLEMENS | Approved | IVRS - Inspection :* |
06/27/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | TMPP CLEARED PER C. CLEMENS |
07/24/2007 | ELECTRIC - UNDERGROUND | CCLEMENS | Approved | IVRS - Inspection :* OK SITE LIGHTING COVER AS NEEDED DEPTH 18" MIN 24" TRAFFIC AREAS |
09/10/2007 | PLUMBING - ROOF DRAINS | RMYERS | Approved | |
10/16/2007 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection :* OK TO COVER OVERHEAD STILL NEED TO SEE CLOSET FLANGES FCD'S, FLOOR SINKS, FLOOR DRAINS ETC. |
10/16/2007 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* |
10/18/2007 | EXCAVATION/LAYOUT REBAR & ZON | JBURGE | Approved | IVRS - Inspection :* TRASH ENCLOSURE, SOUTH WALL ENTRY AREA |
10/18/2007 | EXT METAL CLIPS/EXT SHEATHING | JBURGE | Approved | IVRS - Inspection :* |
10/18/2007 | STUCCO MESH | JBURGE | Approved | IVRS - Inspection :* |
10/18/2007 | ROOF NAILING | JBURGE | Approved | IVRS - Inspection :* |
10/18/2007 | REINFORCED MASONRY PRE-GROUT | JBURGE | Approved | IVRS - Inspection :* |
10/18/2007 | BUILDING PRE-SLAB | JBURGE | Approved | IVRS - Inspection :* |
10/24/2007 | SHEET ROCK NAILING | JBURGE | Approved | IVRS - Inspection :* SECTIONS #401 & 402 & MRI ROOM CEILING OK TO TAPE PROGRESS AREAS |
10/24/2007 | MECHANICAL - INTERMEDIATE | MRAMBER | Approved | IVRS - Inspection :* |
10/30/2007 | FRAMING | JBURGE | Approved | IVRS - Inspection :* WATER FEATURE CONSTRUCTED AS PER RFI DATED 10/27/07 ALL FRAMING COMPLETE OK TO SHEETROCK |
10/30/2007 | ELECTRIC - INTERMEDIATE | CCLEMENS | Approved | IVRS - Inspection :* OK COVER ROOM 501 & 502 |
12/03/2007 | ELECTRIC - CABLE DROP | CCLEMENS | Approved | IVRS - Inspection : See detailed listing on site.| 999* INSPECTION FOR SERVICE AND DISTRIBUTION 1. NEED TO POST BOND FOR POWER 2. NEED PERFORMANCE TEST FOR SERVICE - NEC 230.95 3. INSTALL SECONDARY CONDUCTORS 4. PROVIDE LETTER OF TORQUE FOR SERVICE 5. HVAC DUCT NOT ALLOWED ABOVE SERVICE - NEC 110.26 F 6. PULL CHILLER FEEDER 7. MAKE SURE ALL FEEDER EQUIPMENT GROUNDS ARE INSTALLED PARTIAL INSPECTION 8. NO OPEN WIRING FOR POWER (FINISH TRIM) 9. INSTALL PANIC HARDWARE FOR SERVICE ROOM DOOR AND ILLUMINATION IN ROOM - NEC 110 |
12/03/2007 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :* |
12/14/2007 | ELECTRIC - ABOVE CEILING | CCLEMENS | Approved | IVRS - Inspection :* OK REMAINDER CEILING TILES IN SUSPENDED CEILINGS |
12/27/2007 | MECHANICAL - ABOVE CEILING | MRAMBER | Approved | IVRS - Inspection :* 1) NORTH END OK EXCEPT MRI, MRI EQUIPMENT ROOMS 1 & 2 |
12/27/2007 | U VALUE FOR WINDOW | JBURGE | Approved | IVRS - Inspection :* 1) BLDG U VALUE FOR WINDOWS |
12/27/2007 | BUILDING ABOVE CEILING | JBURGE | Approved | IVRS - Inspection :* 1) OK TO SET TILES AT ENTRY LOBBY |
01/10/2008 | ELECTRIC - CONSTRUCTION POWER | CCLEMENS | Approved | IVRS - Inspection :* 1) OPEN WIRING NOT TO BE ENERGIZED |
01/16/2008 | ELECTRIC - TEMP POWER FOR TEST | CCLEMENS | Approved | IVRS - Inspection :* |
01/24/2008 | RIGHT OF WAY - FINAL | MOTERO | Approved | PER EMAIL |
01/25/2008 | SIGN - FINAL | JYBARRA | Approved | |
01/25/2008 | FIRE - ALARM FINAL | LTHOMAS | Approved | |
01/25/2008 | SEWER - PRE CONSTRUCTION MTG | RMYERS | Approved | IVRS - Inspection :* |
01/28/2008 | ZONING - FINAL | ACONNOR | Approved | |
02/25/2008 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
02/25/2008 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* CORRECTIONS MADE OK PLUMBING FINAL OK |
02/25/2008 | OUTDOOR LIGHTING FINAL | CCLEMENS | Approved | IVRS - Inspection :* |
02/25/2008 | ELECTRIC - FINAL | CCLEMENS | Approved | IVRS - Inspection :* |
02/25/2008 | ELECTRIC - OUTDOOR LIGHTING | CCLEMENS | Approved | IVRS - Inspection :* |
02/25/2008 | FIRE - FINAL | LTHOMAS | Approved | |
03/10/2008 | BUILDING - FINAL | JBURGE | Approved | IVRS - Inspection :* |
03/10/2008 | NPPO - FINAL | ACONNOR | Approved | |
03/10/2008 | LANDSCAPE - FINAL | ACONNOR | Approved | |
03/11/2008 | PERMIT FINALED | BFLORES | Approved | |
03/11/2008 | ENGINEERING - FINAL | MRUSSO | Approved |