Permit: T06CM05079
Permit Details
Status:
Final
Type:
COMMERCIAL ALTERATION
Address:
2539 N BALBOA AV #115
Address NEW:
2539 N BALBOA AV #115
Apply Date:
09/19/2006
Applicant:
SUSAN PETRUS
Description:
REMODEL: OFFICE/WAREHOUSE Suite #101 R1- removed canopys form suite
Contractors:
- KITTLE DESIGN AND CONSTRUCTION L L C
Permit Reviews
Permit Number - T06CM05079
Permit Status: Final
Permit Description: REMODEL: OFFICE/WAREHOUSE
Suite #101
R1- removed canopys form suite
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/09/2007 | 3RD PARTY REVIEW-REVISION/OTHER | 08/10/2007 | COMPLETED |
| 09/19/2006 | PLANS OK TO SUBMIT - 3RD PARTY | 09/22/2006 | COMPLETED |
| 09/22/2006 | 3RD PARTY REVIEW-COMMERCIAL TI | 12/19/2006 | COMPLETED |
| 12/19/2006 | POST 3RD PARTY REVIEW | 01/02/2007 | COMPLETED |
| 12/28/2006 | RESUBMITTAL | 01/03/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM05079
Permit Status: Final
Permit Description: REMODEL: OFFICE/WAREHOUSE
Suite #101
R1- removed canopys form suite
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/19/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T06CM05079
Permit Description: REMODEL: OFFICE/WAREHOUSE
Suite #101
R1- removed canopys form suite
Total Completed Inspections - 26
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/09/2007 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* REPLACED DOUBLE WYE WITH 2 ABS COMBOS OK TO COVER |
| 03/08/2007 | REINFORCED MASONRY PRE-GROUT | AQUIROZ | Approved | IVRS - Inspection :* |
| 03/12/2007 | FRAMING | AQUIROZ | Approved | IVRS - Inspection :* |
| 03/26/2007 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 05/30/2007 | PLUMBING - GAS RECONNECT | RMYERS | Approved | IVRS - Inspection :* |
| 05/30/2007 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection :* |
| 06/04/2007 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :* NOT A CONDENSATE WASTE |
| 06/04/2007 | ELECTRIC - UNDERGROUND | RJIROUDE | Approved | IVRS - Inspection :* |
| 07/06/2007 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
| 07/06/2007 | FIRE - FINAL | LLAKEY | Approved | |
| 08/10/2007 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* 1) PLUMBING FINAL OK |
| 08/10/2007 | OUTDOOR LIGHTING FINAL | DSANTACR | Approved | IVRS - Inspection :* |
| 08/10/2007 | ELECTRIC - OUTDOOR LIGHTING | DSANTACR | Approved | IVRS - Inspection :* |
| 08/31/2007 | U VALUE FOR WINDOW | AQUIROZ | Approved | IVRS - Inspection :* |
| 08/31/2007 | ENGINEERING - FINAL | NKALAHAR | Approved | SEE T06CM05132 |
| 09/04/2007 | RIGHT OF WAY - FINAL | MOTERO | Approved | PER EMAIL |
| 09/12/2007 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* |
| 09/12/2007 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* OK FOR SHEETROCK |
| 09/12/2007 | NPPO - FINAL | ACONNOR | Approved | |
| 09/12/2007 | LANDSCAPE - FINAL | ACONNOR | Approved | |
| 11/13/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | TEC CLEARED FOR #115 PER C. CLEMENS |
| 11/16/2007 | ELECTRIC - FINAL | CCLEMENS | Approved | IVRS - Inspection : See detailed listing on site.| 999* ON ROOF 1. SERVICE RECEPTACLE REQUIRED WITHIN 25' AND ON SAME LEVEL AS AC 2. AC DISCONNECT NOT IDENTIFIED, NOT GROUNDED, AND OVER FUSED 3. EMT TO DISCONNECT TO BE RAN SO IT IS NOT A TRIPPING HAZARD/NOT SUBJECT TO PHYSICAL DAMAGE 4. WATER HEATER TO HAVE PROPER J-BOX ACCESS AND LOCK OUT DEVICE 5. GATE MOTOR NOT IN |
| 11/16/2007 | ELECTRIC - ABOVE CEILING | CCLEMENS | Approved | IVRS - Inspection :* |
| 11/16/2007 | ELECTRIC - INTERMEDIATE | CCLEMENS | Approved | IVRS - Inspection :* |
| 01/08/2008 | SIGN - FINAL | JYBARRA | Approved | |
| 02/13/2008 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection :* OK C OF O |