Permit: T06CM04256
Permit Details
Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
2200 N WILMOT RD #100
Address NEW:
2200 N WILMOT RD #100
Apply Date:
07/20/2006
Applicant:
CARHUFF, PHILIP ANDREW
Description:
TI: OFFICE PRINT SHOP
Permit Reviews
Permit Number - T06CM04256
Permit Status: C of o
Permit Description: TI: OFFICE PRINT SHOP
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/20/2006 | COMMERCIAL TI | 08/08/2006 | COMPLETED |
| 08/08/2006 | OTHER | 08/14/2006 | COMPLETED |
| 11/08/2006 | REVISION - - 1ST | 11/21/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM04256
Permit Status: C of o
Permit Description: TI: OFFICE PRINT SHOP
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 07/20/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T06CM04256
Permit Description: TI: OFFICE PRINT SHOP
Total Completed Inspections - 16
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/15/2006 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* - CONDENSATE DRAINS TO BE 3/4" ENTIRE LENGTH. - PROVIDE A TRAP ON FAN COIL DRAINS 2ND FLR & 1ST FLR - PROVIDE A SHEET METAL VENT CONNECTOR WITH MIN. 3 SCREWS IN EACH JOINT 1ST FLOOR FURNACE. - MUST USE DOUBLE WALL OUTSIDE. - OPEN FAN COILS & REPAIR ANY WATER LEAKS. - REPAIR INSULATION ON CONDENSOR PIPING & SUPPORT REFER LINES. - PROVIDE A DRAIN ON COOLING TOWER TO AN APPROVED LOCATION. |
| 08/15/2006 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection :* 1. FILL UNUSED OPENINGS IN PANELS AND LABEL BREAKERS 2. MISSING OUTLET COVER 3. PROTECT BULB IN CLOSET 4. CORD NOT FOR PERMANENT WIRING 5. SUPPORT OUTLET IN CEILING GRID 6. USE APPROVED HANDLE TIE 7. MAINTAIN WORKING CLEARANCES IN FRONT OF PANELS 36" X 30" 8. FILL UNUSED OPENINGS IN JUNCTION BOXES 9. USE APPROVED FITTINGS 10. LABEL DISCONNECTS 11. USE APPROVED BOX COVERS 12. SUPPORT VDV CABLEING. |
| 08/15/2006 | OUTDOOR LIGHTING FINAL | RHOLLAND | Approved | IVRS - Inspection :* |
| 08/15/2006 | ELECTRIC - OUTDOOR LIGHTING | RHOLLAND | Approved | IVRS - Inspection :* |
| 08/15/2006 | ELECTRIC - ABOVE CEILING | RHOLLAND | Approved | IVRS - Inspection :* |
| 08/15/2006 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection :* |
| 08/16/2006 | PLUMBING - FINAL | BBENEDON | Approved | IVRS - Inspection : See detailed listing on site.| 999* - URINALS REQUIRE VACUUM BREAKERS AND A RIGDID PIPE CONNECTION. - HOSE BIB REQUIRES A VAC BREAKERS - ALL FIXTURES REQUIRE CAULKING AT CONNECTION TO FLOOR OR WALL. - TOILETS REQUIRED TO HAVE OPEN FRONT SEATS. - A SINK HAS BEEN ADDED WITHOUT INSPECTION, THIS MUST BE REMOVED OR PERMITTED. - THE CONNECTION TO THE EXISTING PLUMBING SHALL BE EXPOSED FOR INSPECTION. - WATER HEATER T&P NOT TERMINATED, PIPING NOT SUPPORTED. VALVE NOT FULL PORT. |
| 01/31/2007 | BUILDING - FINAL | GDABBS | Approved | IVRS - Inspection :* |
| 02/01/2007 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | |
| 02/01/2007 | PLUMBING - INTERMEDIATE | BBENEDON | Approved | |
| 02/01/2007 | NPPO - FINAL | ACONNOR | Approved | N/A |
| 02/01/2007 | LANDSCAPE - FINAL | ACONNOR | Approved | N/A |
| 02/01/2007 | RIGHT OF WAY - FINAL | PWHIDDON | Approved | PER EMAIL |
| 02/01/2007 | FIRE - FINAL | LTHOMAS | Approved | |
| 04/27/2007 | ENGINEERING - FINAL | JBRUCKME | Approved | |
| 06/07/2007 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |