Permit: T06CM03269
Permit Details
Apply Date:
05/31/2006
Applicant:
JOAQUIN RINCON
Description:
NEW AUTO SHOP
Architects:
- QUIHUIS, DANNY XAVIER
Contractors:
- BOULDER CANYON BUILDERS INC
Permit Reviews
Permit Number - T06CM03269
Permit Status: C of o
Permit Description: NEW AUTO SHOP
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/23/2007 | PLANS OK TO SUBMIT - COMM | 01/25/2007 | COMPLETED |
01/25/2007 | RESUBMITTAL - SITE | 02/15/2007 | COMPLETED |
02/07/2007 | 3RD PARTY REVIEW-COMMERCIAL | 04/05/2007 | COMPLETED |
02/16/2007 | RESUBMITTAL - SITE ALL | 03/22/2007 | COMPLETED |
04/05/2007 | POST 3RD PARTY REVIEW | 05/18/2007 | COMPLETED |
04/19/2007 | SITE | 05/18/2007 | COMPLETED |
05/31/2006 | PLANS OK TO SUBMIT - SITE | 06/01/2006 | COMPLETED |
06/01/2006 | SITE | 08/10/2006 | COMPLETED |
07/03/2007 | RESUBMITTAL - SITE ALL | 07/26/2007 | COMPLETED |
07/14/2006 | OTHER | 07/25/2006 | COMPLETED |
07/16/2007 | RESUBMITTAL | 07/19/2007 | COMPLETED |
07/19/2007 | RESUBMITTAL | 07/26/2007 | COMPLETED |
11/30/2007 | 3RD PARTY REVIEW-REVISION/OTHER | 12/03/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM03269
Permit Status: C of o
Permit Description: NEW AUTO SHOP
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
05/31/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T06CM03269
Permit Description: NEW AUTO SHOP
Total Completed Inspections - 45
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/27/2007 | ELECTRIC - UFER | CCLEMENS | Approved | IVRS - Inspection :* ONE LINE DIAGRAM TO BE REVISED TO SHOW ACTUAL SERVICE CONFIGURATION AND AMPERAGE |
08/29/2007 | STEM WALL/RETAINING WALL | AQUIROZ | Approved | IVRS - Inspection :* |
09/14/2007 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | IVRS - Inspection :* AFTER HRS. INSP. CK. #2301 FOR $108.00 |
09/14/2007 | BUILDING PRE-SLAB | AQUIROZ | Approved | IVRS - Inspection :* AFTER HRS. INSP. CK. #2301 FOR $108.00 |
09/14/2007 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* |
09/14/2007 | PLUMBING - PRE SLAB | RMYERS | Approved | IVRS - Inspection :* |
10/08/2007 | REINFORCED MASONRY PRE-GROUT | AQUIROZ | Approved | IVRS - Inspection :* |
10/24/2007 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection :* RPBP NOT INSTALLED PER PLAN - OK TO COVER |
10/24/2007 | SITE - SEWER | RMYERS | Approved | IVRS - Inspection :* |
10/24/2007 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection :* |
11/06/2007 | ELECTRIC - UNDERGROUND | CCLEMENS | Approved | IVRS - Inspection :* OK SERVICE TRENCH & GROUND RODS UFER TO BE BONDED TO G.E.C |
11/09/2007 | ROOF NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
11/15/2007 | ELECTRIC - PROGRESS | CCLEMENS | Approved | IVRS - Inspection :* |
11/27/2007 | BUILDING - PROGRESS | AQUIROZ | Approved | IVRS - Inspection :* |
11/29/2007 | FRAMING | AQUIROZ | Approved | IVRS - Inspection :* |
11/30/2007 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
11/30/2007 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection :* |
11/30/2007 | PLUMBING - PROGRESS | RMYERS | Approved | IVRS - Inspection :* |
11/30/2007 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection :* |
12/04/2007 | BUILDING ABOVE CEILING | AQUIROZ | Approved | IVRS - Inspection :* |
12/14/2007 | MECHANICAL - INTERMEDIATE | MRAMBER | Approved | IVRS - Inspection :* - PROVIDE CLEARANCE TO COMBUSTIBLES ON ALL B-VENT PIPING - PROVIDE DIRT LEGS ON ALL GAS APPLIANCES - INSTALL DUCT PER DETAIL 105-M2.1 |
12/14/2007 | ELECTRIC - INTERMEDIATE | CCLEMENS | Approved | IVRS - Inspection :* OK HARD LIDS BATHROOM SERVICE INSPECTION 1. NEED TO POST BOND FOR POWER 2. INSTALL FUSES 3. IDENTIFY SERVICE DISCONNECTS - NEC 230.72 B 4. REMOVE ALL PAINT UNDER LUGS - NEC 250.12 5. ARRANGE BONDING CONDUCTORS TO PREVENT OBJECTIONABLE CURRENT - NEC 250.6 6. BONDING CONDUCTORS UNDERSIZED - NEC 250.102 C 7. BOND METAL PIPING TO SERVICE - GAS/WATER/AIR - NEC 250.104 |
12/14/2007 | U VALUE FOR WINDOW | AQUIROZ | Approved | IVRS - Inspection :* |
12/14/2007 | FIRE - FINAL | LTHOMAS | Approved | |
12/17/2007 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :* |
12/17/2007 | ENGINEERING - FINAL | MRUSSO | Approved | 1) INSTALL GATES ON TRASH ENCLOSURE 2) CHANGE TO FLOW PATTERN IN PARKING LOT ALONG EAST SIDE OF BLDG FROM NORTH TO SOUTH - OK 3) PROVIDE LETTER FROM ENGINEER OF RECORD OMITTING HC RAMPS AND ACCESS STRIPING THAT TIE INTO ADJACENT BUSINESSES, OR BUILD PER PLAN. 4) FOR TEMP C OF O ONLY, PROVIDE SAFE, UNOBSTRUCTED ACCESS FOR PUBLC SEPARATED FRON CONSTRUCTION ACTIVITY. |
12/18/2007 | MECHANICAL - ABOVE CEILING | MRAMBER | Approved | IVRS - Inspection :* PROVIDE FIRE DAMPER AT PARTS STORAGE FIREWALL 304.3 WATER HEATER NOT ALLOWED IN COMBUSTIBLE STORAGE ROOM OFFICE AREA OK FOR TILES |
12/18/2007 | ELECTRIC - TEMPORARY SERVICE | CCLEMENS | Approved | IVRS - Inspection :* 1) DO NOT ENERGIZE OPEN WIRING |
12/19/2007 | ELECTRIC - ABOVE CEILING | CCLEMENS | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1. ALL LOW VOLTAGE WIRING TO BE RAN IN A NEAT AND WORKMANLIKE MANNER PROPERLY SECURED TO BUILDING STRUCTURE 2. FINISH ALL LOW VOLTAGE WIRING OK CEILING TILES, HAVE CORRECTIONS DONE FOR FINAL |
12/19/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | TEC CLEARED PER C. CLEMENS |
01/10/2008 | RIGHT OF WAY - FINAL | MOTERO | Approved | |
01/15/2008 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* |
01/15/2008 | PLUMBING - GAS PRESS TEST FNL | RMYERS | Approved | IVRS - Inspection :* |
01/15/2008 | NPPO - FINAL | ACONNOR | Approved | |
01/15/2008 | LANDSCAPE - FINAL | ACONNOR | Approved | |
01/18/2008 | ELECTRIC - CABLE DROP | CCLEMENS | Approved | IVRS - Inspection :* |
01/18/2008 | ELECTRIC - OUTDOOR LIGHTING | CCLEMENS | Approved | IVRS - Inspection :* |
01/18/2008 | OUTDOOR LIGHTING FINAL | CCLEMENS | Approved | IVRS - Inspection :* |
01/31/2008 | ELECTRIC - FINAL | RJIROUDE | Approved | IVRS - Inspection :* |
02/01/2008 | MECHANICAL - FINAL | MRAMBER | Approved | IVRS - Inspection :* |
02/01/2008 | MECHANICAL - PROGRESS | MRAMBER | Approved | IVRS - Inspection :* |
02/04/2008 | SIGN - FINAL | JYBARRA | Approved | |
02/04/2008 | SIGN - FINAL | JYBARRA | Approved | NEED TO PAY 62.50 FOR BANNER PERMIT THEN OK FOR C OF O |
02/04/2008 | STUCCO MESH | AQUIROZ | Approved | PER BU FINAL |
02/04/2008 | BUILDING - FINAL | AQUIROZ | Approved | PER INSP COPY |