Permit Details

Status:
C of o
Type:
COMMERCIAL NEW
Address:
2496 E RIVER RD
Address NEW:
2496 E RIVER RD
Apply Date:
05/19/2006
Applicant:
METRO PERMIT EXPRESS, INC *C
Description:
NEW: MEDICAL OFFICE
Contractors:
  • CAYLOR CONSTRUCTION COMPANY , RO

Permit Reviews

Permit Number - T06CM03002
Permit Status: C of o
Permit Description: NEW: MEDICAL OFFICE
Start Date Submittal Complete Date Status  
02/27/2007 3RD PARTY REVIEW-REVISION/OTHER 02/27/2007 COMPLETED Review Details
05/19/2006 PLANS OK TO SUBMIT - 3RD PARTY 05/22/2006 COMPLETED Review Details
05/19/2006 SITE 08/07/2006 COMPLETED Review Details
05/22/2006 3RD PARTY REVIEW-COMMERCIAL 07/31/2006 COMPLETED Review Details
07/31/2006 POST 3RD PARTY REVIEW 11/02/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06CM03002
Permit Status: C of o
Permit Description: NEW: MEDICAL OFFICE
Total Outstanding Activity Conditions - 1
Date Name
05/19/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T06CM03002
Permit Description: NEW: MEDICAL OFFICE
Total Completed Inspections - 42
Date Description Inspector Results Comments
09/06/2006 EXCAVATION/LAYOUT REBAR & ZON LHANLY Approved IVRS - Inspection :*
POST YOUR ADDRESS!
09/06/2006 ELECTRIC - UFER CCLEMENS Approved IVRS - Inspection :*
CONNECT CLAMP TO REBAR AS IT IS LISTED TO BE CONNECTED SO IT WILL NOT BE LOOSE.

TURN BOTTOMS UPSIDE DOWN AND TIGHTEN TO SINGLE REBAR.
09/11/2006 ENGINEERING - FINAL MRUSSO Approved SEE STORM WATER FOLLOW UP INSPECTION
09/21/2006 STORMWATER FOLLOW-UP INSP MRUSSO Approved THE MAJORITY OF SOIL IN THE PARKING AREA HAS BEEN CLEANED UP.
EXCESS MATERIAL FROM MIXING OF MORTAR HAS BEEN REMOVED.
CONTINUE TO SWEEP PARKING AREA ROUTINELY.
PROVIDE CONTAINMENT FOR MORTAR MIXING OPERATIONS.
ROUTINE INSPECTIONS WILL BE PERFORMED TO ENSURE COMPLIANCE.
10/23/2006 BUILDING PRE-SLAB AQUIROZ Approved IVRS - Inspection :*
EXCAVATION OK
10/23/2006 ELECTRIC - INTERMEDIATE CCLEMENS Approved IVRS - Inspection :*
1 -- UFER
3 -- BOND WIPS
11/06/2006 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection :*
1. YOU ARE REQUIRED TO HAVE INSPECTION HISTORY ON SITE AT ALL TIMES!
2. PROVIDE SITE UTILITY PLAN, SHOWING SEWER AND WATER
3. ABS DWV UNDERGROUND INSIDE BLDG OK TO COVER
WATER TEST, ONE RISER TO TEN FEET.
4. UNABLE TO LOCATE YARDWATER PIPING.
11/06/2006 PLUMBING - SEWER HCS CONNECT RMYERS Approved IVRS - Inspection :*
11/06/2006 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection :*
12/12/2006 ELECTRIC - UNDERGROUND CCLEMENS Approved IVRS - Inspection :*
RACEWAY INSPECTION FOR SERVICE LATERAL.

OK SERVICE LATERAL - INSTALL WARNING RIBBON BEFORE BACKFILL - NEC 300.5 MIN. 12" ABOVE RACEWAYS.
12/15/2006 REINFORCED MASONRY PRE-GROUT GDABBS Approved IVRS - Inspection :*
TOP AT NORTH 8" CMU PERIMETER WALL
01/03/2007 PLUMBING - PRE SLAB RMYERS Approved IVRS - Inspection :*
1. PLEASE POST YOUR ADDRESS!
2. OK FOR CONCRETE
01/22/2007 ELECTRIC - CABLE DROP CCLEMENS Approved IVRS - Inspection :*
SERVICE INSPECTION ONLY
IDENTIFY SERVICE DISCONNECTS - NEC 230.70B
02/07/2007 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
1) SUSPENDED ROUGH DUCT OK TO PROCEED
2) CONDENSATE IN WALL OK
3) OK TO SHEETROCK HARD LIDS
4) WILL CHECK SUPPLY AND EXHAUST FROM OVERHEAD
02/07/2007 ROOF NAILING AQUIROZ Approved IVRS - Inspection :*
02/12/2007 FRAMING AQUIROZ Approved IVRS - Inspection :*
02/14/2007 PLUMBING - INTERMEDIATE RMYERS Approved 1. REQUIRE PLUMBING NOTES AND SPEC'S
2. OK TO INSULATE HOT
3. OK TO COVER ALL AREAS AFTER INSULATION
02/14/2007 PLUMBING - ROOF DRAINS RMYERS Approved
02/15/2007 STUCCO MESH AQUIROZ Approved IVRS - Inspection :*
02/22/2007 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection :*
02/23/2007 TEP CLEARANCE - AM JWEATHER Approved TEC CLEARED FOR #1M & #2M PER C. CLEMENS
03/29/2007 BUILDING ABOVE CEILING JBURGE Approved OK TO SET TILE
03/29/2007 U VALUE FOR WINDOW JBURGE Approved IVRS - Inspection :*
03/29/2007 EXT METAL CLIPS/EXT SHEATHING JBURGE Approved IVRS - Inspection :*
05/04/2007 LANDSCAPE - FINAL ACONNOR Approved
05/04/2007 NPPO - FINAL ACONNOR Approved
05/04/2007 SIGN - FINAL JYBARRA Approved
05/08/2007 ELECTRIC - ABOVE CEILING CCLEMENS Approved IVRS - Inspection :*
05/14/2007 BUILDING - FINAL JBURGE Approved IVRS - Inspection :*
ENSURE ALL NECESSARY SIGNAGE IS IN PLACE
05/14/2007 ELECTRIC - CONSTRUCTION POWER CCLEMENS Approved IVRS - Inspection :*
05/14/2007 ELECTRIC - TEMPORARY SERVICE CCLEMENS Approved IVRS - Inspection :*
05/14/2007 FIRE SPKLR - UG PIPING FLUSH LTHOMAS Approved
05/14/2007 FIRE SPKLR - FINAL LTHOMAS Approved
05/14/2007 FIRE SPKLR - UG, PIPING, HYDRO LTHOMAS Approved
05/14/2007 FIRE - FINAL LTHOMAS Approved
05/15/2007 RIGHT OF WAY - FINAL MOTERO Approved
05/15/2007 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection :*
05/18/2007 OUTDOOR LIGHTING FINAL CCLEMENS Approved IVRS - Inspection :*
05/18/2007 ELECTRIC - OUTDOOR LIGHTING CCLEMENS Approved IVRS - Inspection :*
05/25/2007 ELECTRIC - FINAL RMAJUTA Approved IVRS - Inspection :*
06/20/2007 PERMIT FINALED BFLORES Approved
06/20/2007 PLUMBING - FINAL RMYERS Approved IVRS - Inspection :*

Documents

File Name Document Type  
C OF O_06-22-2007.TIF CERT OF OCC VIEW
None DOCUMENTS VIEW
REV#1 CONSTRPLANS VIEW
ORIGINAL CONSTRPLANS VIEW
3002-01-0003-01-0002.TIF CONSTRPLANS VIEW
3002-01-0003-01-0003.TIF CONSTRPLANS VIEW
3002-01-0003-01-0004.TIF CONSTRPLANS VIEW
3002-01-0003-01-0005.TIF CONSTRPLANS VIEW
3002-01-0003-01-0006.TIF CONSTRPLANS VIEW
3002-01-0003-01-0007.TIF CONSTRPLANS VIEW
3002-01-0003-01-0008.TIF CONSTRPLANS VIEW
3002-01-0003-01-0009.TIF CONSTRPLANS VIEW
3002-01-0003-01-0010.TIF CONSTRPLANS VIEW
3002-01-0003-01-0011.TIF CONSTRPLANS VIEW
3002-01-0003-01-0012.TIF CONSTRPLANS VIEW
3002-01-0003-01-0013.TIF CONSTRPLANS VIEW
3002-01-0003-01-0014.TIF CONSTRPLANS VIEW
3002-01-0003-01-0015.TIF CONSTRPLANS VIEW
3002-01-0003-01-0016.TIF CONSTRPLANS VIEW
3002-01-0003-01-0017.TIF CONSTRPLANS VIEW
3002-01-0003-01-0018.TIF CONSTRPLANS VIEW
3002-01-0003-01-0019.TIF CONSTRPLANS VIEW
3002-01-0003-01-0020.TIF CONSTRPLANS VIEW
3002-01-0003-01-0021.TIF CONSTRPLANS VIEW
3002-01-0003-01-0022.TIF CONSTRPLANS VIEW
3002-01-0003-01-0023.TIF CONSTRPLANS VIEW
3002-01-0003-01-0024.TIF CONSTRPLANS VIEW
3002-01-0003-01-0025.TIF CONSTRPLANS VIEW
3002-01-0003-01-0026.TIF CONSTRPLANS VIEW
3002-01-0003-01-0027.TIF CONSTRPLANS VIEW
3002-01-0003-01-0028.TIF CONSTRPLANS VIEW
3002-01-0003-01-0029.TIF CONSTRPLANS VIEW
3002-01-0003-01-0030.TIF CONSTRPLANS VIEW
3002-01-0003-01-0031.TIF CONSTRPLANS VIEW
3002-01-0003-01-0032.TIF CONSTRPLANS VIEW
3002-01-0003-01-0033.TIF CONSTRPLANS VIEW
3002-01-0003-01-0034.TIF CONSTRPLANS VIEW
3002-01-0003-01-0035.TIF CONSTRPLANS VIEW
3002-01-0003-01-0036.TIF CONSTRPLANS VIEW
3002-01-0003-01-0037.TIF CONSTRPLANS VIEW
3002-01-0003-01-0038.TIF CONSTRPLANS VIEW
3002-01-0003-01-0039.TIF CONSTRPLANS VIEW
3002-01-0003-01-0040.TIF CONSTRPLANS VIEW
3002-01-0003-01-0041.TIF CONSTRPLANS VIEW
3002-01-0003-01-0042.TIF CONSTRPLANS VIEW
3002-01-0003-01-0043.TIF CONSTRPLANS VIEW
3002-01-0003-01-0044.TIF CONSTRPLANS VIEW
3002-01-0003-01-0045.TIF CONSTRPLANS VIEW
3002-01-0003-01-0046.TIF CONSTRPLANS VIEW
3002-01-0003-01-0047.TIF CONSTRPLANS VIEW
3002-01-0003-01-0048.TIF CONSTRPLANS VIEW
3002-01-0003-01-0049.TIF CONSTRPLANS VIEW
3002-01-0003-01-0050.TIF CONSTRPLANS VIEW
3002-01-0003-01-0051.TIF CONSTRPLANS VIEW
3002-01-0003-01-0052.TIF CONSTRPLANS VIEW
3002-01-0003-01-0053.TIF CONSTRPLANS VIEW
3002-01-0003-01-0054.TIF CONSTRPLANS VIEW
None CONSTRPLANS VIEW