Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
MULTI FAMILY ALTERATION
Apply Date:
05/17/2006
Applicant:
DAVID DOBSON
Description:
REMODEL:CONDO'S BLDG # 1 Revision #1 Relocate Plumbing fixtures
Contractors:
  • MATRIX ARIZONA
  • ROOF U S A SERVICE CENTER ARIZONA L L C
  • SOUTHERN ARIZONA PAINTING L L C
  • SPARTAN PLUMBING INC

Permit Reviews

Permit Number - T06CM02940
Permit Status: Final
Permit Description: REMODEL:CONDO'S BLDG # 1 Revision #1 Relocate Plumbing fixtures
Start Date Submittal Complete Date Status  
05/17/2006 PLANS OK TO SUBMIT - COMM 05/23/2006 COMPLETED Review Details
05/23/2006 3RD PARTY REVIEW-COMMERCIAL TI 08/21/2006 COMPLETED Review Details
08/21/2006 POST 3RD PARTY REVIEW 08/28/2006 COMPLETED Review Details
11/06/2006 3RD PARTY REVIEW-REVISION/OTHER 11/06/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06CM02940
Permit Status: Final
Permit Description: REMODEL:CONDO'S BLDG # 1 Revision #1 Relocate Plumbing fixtures
Total Outstanding Activity Conditions - 1
Date Name
05/17/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T06CM02940
Permit Description: REMODEL:CONDO'S BLDG # 1 Revision #1 Relocate Plumbing fixtures
Total Completed Inspections - 18
Date Description Inspector Results Comments
08/31/2006 ELECTRIC - ABOVE CEILING RMAJUTA Approved IVRS - Inspection :*
08/31/2006 ELECTRIC - INTERMEDIATE RMAJUTA Approved IVRS - Inspection :*
09/21/2006 ROOF NAILING GDABBS Approved IVRS - Inspection :*
09/25/2006 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
09/25/2006 SHEET ROCK NAILING GDABBS Approved IVRS - Inspection :*
2ND FLOOR UNITS 201 THRU 212
11/09/2006 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection :*
WATER TEST WASTE & VENT THRU ROOF OK
WATER PIPING & TUB SHOWER VALVES OK
11/09/2006 FRAMING GDABBS Approved IVRS - Inspection :*
11/21/2006 STUCCO MESH GDABBS Approved IVRS - Inspection :*
04/24/2007 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
04/27/2007 TEP CLEARANCE - AM JWEATHER Approved RECN CLEARED FOR BLDG #1, UNITS #104 & #204
06/20/2007 PLUMBING - FINAL RRICH Approved IVRS - Inspection :*
#104, 105, 106, 203, 204, 205, 206, 112, 211, 212, 110, 210 OK
06/20/2007 PLUMBING - ABOVE CEILING RRICH Approved IVRS - Inspection :*
06/22/2007 ELECTRIC - FINAL RJIROUDE Approved IVRS - Inspection :*
07/11/2007 BUILDING - FINAL GDABBS Approved IVRS - Inspection :*
07/13/2007 PERMIT FINALED BFLORES Approved
07/13/2007 U VALUE FOR WINDOW GDABBS Approved
07/13/2007 BUILDING ABOVE CEILING GDABBS Approved
07/13/2007 EXT METAL CLIPS/EXT SHEATHING GDABBS Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
REV#1 CONSTRPLANS VIEW
ORIGINAL CONSTRPLANS VIEW
2940-01-0002-01-0002.TIF CONSTRPLANS VIEW
2940-01-0002-01-0003.TIF CONSTRPLANS VIEW
2940-01-0002-01-0004.TIF CONSTRPLANS VIEW
2940-01-0002-01-0005.TIF CONSTRPLANS VIEW
2940-01-0002-01-0006.TIF CONSTRPLANS VIEW
2940-01-0002-01-0007.TIF CONSTRPLANS VIEW
2940-01-0002-01-0008.TIF CONSTRPLANS VIEW
2940-01-0002-01-0009.TIF CONSTRPLANS VIEW
2940-01-0002-01-0010.TIF CONSTRPLANS VIEW
2940-01-0002-01-0011.TIF CONSTRPLANS VIEW
2940-01-0002-01-0012.TIF CONSTRPLANS VIEW
2940-01-0002-01-0013.TIF CONSTRPLANS VIEW
2940-01-0002-01-0014.TIF CONSTRPLANS VIEW
2940-01-0002-01-0015.TIF CONSTRPLANS VIEW
2940-01-0002-01-0016.TIF CONSTRPLANS VIEW
2940-01-0002-01-0017.TIF CONSTRPLANS VIEW
2940-01-0002-01-0018.TIF CONSTRPLANS VIEW
2940-01-0002-01-0019.TIF CONSTRPLANS VIEW
2940-01-0002-01-0020.TIF CONSTRPLANS VIEW
2940-01-0002-01-0021.TIF CONSTRPLANS VIEW
2940-01-0002-01-0022.TIF CONSTRPLANS VIEW
2940-01-0002-01-0023.TIF CONSTRPLANS VIEW
2940-01-0002-01-0024.TIF CONSTRPLANS VIEW
2940-01-0002-01-0025.TIF CONSTRPLANS VIEW
2940-01-0002-01-0026.TIF CONSTRPLANS VIEW
2940-01-0002-01-0027.TIF CONSTRPLANS VIEW
2940-01-0002-01-0028.TIF CONSTRPLANS VIEW
2940-01-0002-01-0029.TIF CONSTRPLANS VIEW
2940-01-0002-01-0030.TIF CONSTRPLANS VIEW
2940-01-0002-01-0031.TIF CONSTRPLANS VIEW
2940-01-0002-01-0032.TIF CONSTRPLANS VIEW
2940-01-0002-01-0033.TIF CONSTRPLANS VIEW
2940-01-0002-01-0034.TIF CONSTRPLANS VIEW
2940-01-0002-01-0035.TIF CONSTRPLANS VIEW
2940-01-0002-01-0036.TIF CONSTRPLANS VIEW
2940-01-0002-01-0037.TIF CONSTRPLANS VIEW
2940-01-0002-01-0038.TIF CONSTRPLANS VIEW
2940-01-0002-01-0039.TIF CONSTRPLANS VIEW
2940-01-0002-01-0040.TIF CONSTRPLANS VIEW
2940-01-0002-01-0041.TIF CONSTRPLANS VIEW
2940-01-0002-01-0042.TIF CONSTRPLANS VIEW
2940-01-0002-01-0043.TIF CONSTRPLANS VIEW
2940-01-0002-01-0044.TIF CONSTRPLANS VIEW
2940-01-0002-01-0045.TIF CONSTRPLANS VIEW
2940-01-0002-01-0046.TIF CONSTRPLANS VIEW
2940-01-0002-01-0047.TIF CONSTRPLANS VIEW
2940-01-0002-01-0048.TIF CONSTRPLANS VIEW
2940-01-0002-01-0049.TIF CONSTRPLANS VIEW
2940-01-0002-01-0050.TIF CONSTRPLANS VIEW
2940-01-0002-01-0051.TIF CONSTRPLANS VIEW
2940-01-0002-01-0052.TIF CONSTRPLANS VIEW
2940-01-0002-01-0053.TIF CONSTRPLANS VIEW
2940-01-0002-01-0054.TIF CONSTRPLANS VIEW
2940-01-0002-01-0055.TIF CONSTRPLANS VIEW
2940-01-0002-01-0056.TIF CONSTRPLANS VIEW
2940-01-0002-01-0057.TIF CONSTRPLANS VIEW
2940-01-0002-01-0058.TIF CONSTRPLANS VIEW
2940-01-0002-01-0059.TIF CONSTRPLANS VIEW
2940-01-0002-01-0060.TIF CONSTRPLANS VIEW
2940-01-0002-01-0061.TIF CONSTRPLANS VIEW
2940-01-0002-01-0062.TIF CONSTRPLANS VIEW
2940-01-0002-01-0063.TIF CONSTRPLANS VIEW
2940-01-0002-01-0064.TIF CONSTRPLANS VIEW
2940-01-0002-01-0065.TIF CONSTRPLANS VIEW
2940-01-0002-01-0066.TIF CONSTRPLANS VIEW
2940-01-0002-01-0067.TIF CONSTRPLANS VIEW
2940-01-0002-01-0068.TIF CONSTRPLANS VIEW