Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T06CM02940
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/09/2006 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* WATER TEST WASTE & VENT THRU ROOF OK WATER PIPING & TUB SHOWER VALVES OK |
|
11/02/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) READ ALL NOTES: PROVIDE TESTING ON ALL PIPING, PROVIDE REVISED APPROVED PLAN AND COMPLY OR BE REFEED |
|
10/27/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* UNITS 107 & 108 WOULD BE OK TO COVER IF PER APPROVED PLAN SECURE WASHER BOXES. CLEAN OUT SHALL BE ACCESSIBLE. PIPING IN WALL. PROVIDE PLAN AND PROOF STRUCTURAL INSPECTION SECURE WATER TUBING, PROTECT TUBING FROM FHA STRAPS. FOAM PIPE WRAP ON PIPING PENETRATING FLOOR. |
|
10/20/2006 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SHALL PROVIDE CITY APPROVED PLAN OF CLOTHES WASHER DRAINAGE AS REQUESTED ON 9/25/06 2. BUILDING INSPECTOR TO INSPECT BEARING WALL AT THIS LOCATION. |
|
09/25/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. SECURE ALL SHOWER VALVES. 2. WATER HEATERS APPEAR TO BE INSTALLED WITHOUT INSPECTION. ALL T&P DRAINS SHALL GRAVITY DRAIN TO DAYLIGHT WITH RIGID APPROVED PIPING. OFFICE @ 261 3. DRAINAGE FOR WASHER DRYER SHALL GO TO APPROVED RECEPTOR, PLAN IS APPROVED IN ERROR. |