Permit Reviews

Permit Number - T06CM01753
Permit Status: Final
Permit Description: NEW: WAREHOUSE SHELL
Start Date Submittal Complete Date Status  
03/28/2006 PLANS OK TO SUBMIT - 3RD PARTY 03/28/2006 COMPLETED Review Details
03/28/2006 3RD PARTY REVIEW-COMMERCIAL 04/13/2006 COMPLETED Review Details
04/13/2006 POST 3RD PARTY REVIEW 05/16/2006 COMPLETED Review Details
07/12/2007 REVISION - - 1ST 07/12/2007 COMPLETED Review Details
07/27/2006 RESUBMITTAL 11/21/2006 COMPLETED Review Details
07/27/2006 SITE 07/28/2006 COMPLETED Review Details
07/28/2006 OTHER 07/28/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06CM01753
Permit Status: Final
Permit Description: NEW: WAREHOUSE SHELL
Total Outstanding Activity Conditions - 1
Date Name
03/28/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T06CM01753
Permit Description: NEW: WAREHOUSE SHELL
Total Completed Inspections - 40
Date Description Inspector Results Comments
09/28/2006 BUILDING PRE-SLAB GDABBS Approved IVRS - Inspection :*
BLDG. CLOSURE POUR AT COLUMN LINE #1
10/05/2006 ELECTRIC - UNDERGROUND RSUBA Approved IVRS - Inspection :*
- OK 5 2 1/2" FROM CENTER LINE TO COL'S TO SERVICE SECTION.
- OK 4" (1) AT FUTURE EQUIPMENT PAD
- OK 3 - 4" SERVICE FEEDERS
- OK ALL CONDUITS UNDER SLAB @ WAREHOUSE

SEE PLANS AS SIGNED OFF R. SUBA
10/18/2006 EXCAVATION/LAYOUT REBAR & ZON GDABBS Approved IVRS - Inspection :*
LOADING DOCK ON WEST SIDE FOOTING -- OK TO POUR
11/09/2006 REINFORCED MASONRY PRE-GROUT IVR USER Approved IVRS - RI canceled
11/15/2006 PLUMBING - YARD WTR LINE/TEST BBENEDON Approved IVRS - Inspection :*
CORRECT DRIP AT UNION
WIPE SOLDIER JOINTS
11/16/2006 FRAMING GDABBS Approved IVRS - Inspection :*
ROD BRACES & TUBE BRACES NOT COMPLETE
OK TO CONTINUE
11/20/2006 PLUMBING - ROUGH, SOIL RLEDONNE Approved IVRS - Inspection :*
03/05/2007 TEP CLEARANCE - AM JWEATHER Approved TMPP CLEARED PER R. HOLLANDER
04/05/2007 ELECTRIC - FINAL RJIROUDE Approved IVRS - Inspection :*
04/05/2007 ELECTRIC - INTERMEDIATE RJIROUDE Approved IVRS - Inspection :*
04/05/2007 ELECTRIC - TEMPORARY SERVICE RJIROUDE Approved IVRS - Inspection :*
04/16/2007 PLUMBING - INTERMEDIATE RRICH Approved CALL IN ALL PLUMBING INSPECTIONS THAT DO NOT HAVE APPROVAL & PROVIDE INSPECTION HISTORY FOR PLUMBING.
1. SUPPORT VENT PIPING THRU ROOF AT CORRECT INTERVALS ON VERTICAL AND PAINT EXTERIOR VENT PIPING.
2. PROVIDE PERM CAP AT FUTURE URINAL DRAIN STUB.
3. EXPOSE CLEAN OUT FOR UTILITY SINK & PROVIDE CORRECT COVER.
4. SHALL HAVE ONLY (1) SUP JOINT CONNECTION ON DOWNSTREAM SIDE OF P-TRAP AT KITCHEN SINKS.
5. EXPOSE CLEAN OUT FOR DRINKING FOUNTAINS.
6. WATER HEATER T&P DRAIN PENETRATION THRU BUILDING TO BE SEALED.
7. FLOOR SINKS TO BE ACCESSIBLE
8. ICE MAKER TO BE INSTALLED WITH CORRECT BACKFLOW PROTECTION AND CERTIFICATION IF REQUIRED, AND CORRECT DRAIN CONNECTIONS.
9. EXPOSE EXTERIOR SEWER CLEANOUTS & PROVIDE CORRECT TERMINATIONS.
04/19/2007 ELECTRIC - PROGRESS RJIROUDE Approved
04/19/2007 ELECTRIC - OUTDOOR LIGHTING RJIROUDE Approved
04/19/2007 OUTDOOR LIGHTING FINAL RJIROUDE Approved
04/19/2007 ELECTRIC - CABLE DROP RJIROUDE Approved
04/19/2007 ELECTRIC - UFER RJIROUDE Approved
04/23/2007 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
04/23/2007 MECHANICAL - PROGRESS JMILITEL Approved IVRS - Inspection :*
04/23/2007 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
04/23/2007 PLUMBING - FINAL RRICH Approved IVRS - Inspection :*
T.I PLAN DELETED RESTROOM ON THIS PLAN
04/23/2007 SITE - SEWER RRICH Approved IVRS - Inspection :*
APPROVED RDLD ON PERMIT #T06CM04481
04/23/2007 SEPTIC - SYSTEM RRICH Approved IVRS - Inspection :*
PIMA COUNTY APPROVED
04/23/2007 PLUMBING - PROGRESS RRICH Approved IVRS - Inspection :*
04/23/2007 PLUMBING - PRE SLAB RRICH Approved IVRS - Inspection :*
04/23/2007 FIRE - HYDRANTS LTHOMAS Approved
04/23/2007 FIRE SPKLR - FINAL LTHOMAS Approved
04/23/2007 FIRE SPKLR - UG, PIPING, HYDRO LTHOMAS Approved
04/23/2007 RIGHT OF WAY - FINAL SDAMRON Approved PER EMAIL
04/24/2007 BUILDING - FINAL GDABBS Approved IVRS - Inspection :*
04/24/2007 SHEET ROCK NAILING GDABBS Approved IVRS - Inspection :*
04/24/2007 ROOF NAILING GDABBS Approved IVRS - Inspection :*
04/24/2007 EXT METAL CLIPS/EXT SHEATHING GDABBS Approved IVRS - Inspection :*
04/24/2007 FIRE - FINAL LTHOMAS Approved
04/25/2007 BUILDING - PROGRESS GDABBS Approved
05/01/2007 SIGN - FINAL JYBARRA Approved IVRS - Inspection :*
06/06/2007 NPPO - FINAL ACONNOR Approved
06/06/2007 LANDSCAPE - FINAL ACONNOR Approved
07/13/2007 PERMIT FINALED NKALAHAR Approved
07/13/2007 ENGINEERING - FINAL NKALAHAR Approved *RIP RAP OUTFALLS MISSING AT BASIN OUTLET AND AT END OF CONCRETE SWALE (NW CORNER)
*MISSING CONCRETE SWALE FROM SE CORNER OF BUILDING TO EAST
*NO CONCRETE SWALE THROUGH GRAVLE AREA ON EAST SIDE OF BUILDING
*RIP RAP BANK STABILIZATION NOT INSTALLED NE SIDE OF SITE
*TRASH ENCLOSURE AREA NOT BUILT
*INLET SWALE NOT BUILT INTO BASIN FROM BUILDING
CP-REMOVE ALL STORMWATER CONTROLS

*SEE 7/9 ENTRY T06BU01077 AND T06BU01610

Documents

File Name Document Type  
STRUCCALCS.TIF DOCUMENTS VIEW
DESIGNCALCS_01.TIF DOCUMENTS VIEW
DESIGNCALCS_02.TIF DOCUMENTS VIEW
DESIGNCALCS_03.TIF DOCUMENTS VIEW
DESIGNCALCS_04.TIF DOCUMENTS VIEW
DESIGNCALCS_05.TIF DOCUMENTS VIEW
DESIGNCALCS_06.TIF DOCUMENTS VIEW
DESIGNCALCS_07.TIF DOCUMENTS VIEW
DESIGNCALCS_08.TIF DOCUMENTS VIEW
None DOCUMENTS VIEW
T06CM01753-R_01.TIF CONSTRPLANS VIEW
T06CM01753-R_02.TIF CONSTRPLANS VIEW
T06CM01753-R_03.TIF CONSTRPLANS VIEW
T06CM01753-R_04.TIF CONSTRPLANS VIEW
T06CM01753-R_05.TIF CONSTRPLANS VIEW
T06CM01753-R_06.TIF CONSTRPLANS VIEW
T06CM01753-R_07.TIF CONSTRPLANS VIEW
T06CM01753-R_08.TIF CONSTRPLANS VIEW
T06CM01753-R_09.TIF CONSTRPLANS VIEW
T06CM01753-R_10.TIF CONSTRPLANS VIEW
T06CM01753-R_11.TIF CONSTRPLANS VIEW
T06CM01753-R_12.TIF CONSTRPLANS VIEW
T06CM01753-R_13.TIF CONSTRPLANS VIEW
T06CM01753-R_14.TIF CONSTRPLANS VIEW
T06CM01753-R_15.TIF CONSTRPLANS VIEW
T06CM01753-R_16.TIF CONSTRPLANS VIEW
T06CM01753-R_17.TIF CONSTRPLANS VIEW
T06CM01753-R_18.TIF CONSTRPLANS VIEW
T06CM01753-R_19.TIF CONSTRPLANS VIEW
T06CM01753-R_20.TIF CONSTRPLANS VIEW
T06CM01753-R_21.TIF CONSTRPLANS VIEW
T06CM01753-R_22.TIF CONSTRPLANS VIEW
T06CM01753-R_23.TIF CONSTRPLANS VIEW
T06CM01753-R_24.TIF CONSTRPLANS VIEW
T06CM01753-R_25.TIF CONSTRPLANS VIEW
T06CM01753-R_26.TIF CONSTRPLANS VIEW
T06CM01753-R_27.TIF CONSTRPLANS VIEW
T06CM01753-R_28.TIF CONSTRPLANS VIEW
T06CM01753-R_29.TIF CONSTRPLANS VIEW
T06CM01753-R_30.TIF CONSTRPLANS VIEW
None CONSTRPLANS VIEW