Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/16/2007 | PLUMBING - INTERMEDIATE | Approved | CALL IN ALL PLUMBING INSPECTIONS THAT DO NOT HAVE APPROVAL & PROVIDE INSPECTION HISTORY FOR PLUMBING. 1. SUPPORT VENT PIPING THRU ROOF AT CORRECT INTERVALS ON VERTICAL AND PAINT EXTERIOR VENT PIPING. 2. PROVIDE PERM CAP AT FUTURE URINAL DRAIN STUB. 3. EXPOSE CLEAN OUT FOR UTILITY SINK & PROVIDE CORRECT COVER. 4. SHALL HAVE ONLY (1) SUP JOINT CONNECTION ON DOWNSTREAM SIDE OF P-TRAP AT KITCHEN SINKS. 5. EXPOSE CLEAN OUT FOR DRINKING FOUNTAINS. 6. WATER HEATER T&P DRAIN PENETRATION THRU BUILDING TO BE SEALED. 7. FLOOR SINKS TO BE ACCESSIBLE 8. ICE MAKER TO BE INSTALLED WITH CORRECT BACKFLOW PROTECTION AND CERTIFICATION IF REQUIRED, AND CORRECT DRAIN CONNECTIONS. 9. EXPOSE EXTERIOR SEWER CLEANOUTS & PROVIDE CORRECT TERMINATIONS. |