Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
DUPLEX NEW
Address NEW:
3039 N RICHEY BL #01
Apply Date:
02/14/2006
Applicant:
RUGUONE DAVECUSTOM HOMES INC
Description:
NEW: DUPLEX R1 - Plumb pipe size change r-2: as built for gas and waste plumbing
Contractors:
  • RUGUONE DAVECUSTOM HOMES INC

Permit Reviews

Permit Number - T06CM00930
Permit Status: Final
Permit Description: NEW: DUPLEX R1 - Plumb pipe size change r-2: as built for gas and waste plumbing
Start Date Submittal Complete Date Status  
01/04/2007 REVISION - - 3RD 01/04/2007 COMPLETED Review Details
02/14/2006 PLANS OK TO SUBMIT - RES 02/15/2006 COMPLETED Review Details
02/21/2006 RESIDENTIAL BLDG/WWM 03/10/2006 COMPLETED Review Details
04/24/2006 RESUBMITTAL 05/05/2006 COMPLETED Review Details
05/17/2006 RESUBMITTAL 06/20/2006 COMPLETED Review Details
08/10/2006 REVISION - - 1ST 08/10/2006 COMPLETED Review Details
12/26/2006 REVISION - - 2ND 12/26/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06CM00930
Permit Status: Final
Permit Description: NEW: DUPLEX R1 - Plumb pipe size change r-2: as built for gas and waste plumbing
Total Outstanding Activity Conditions - 1
Date Name
02/14/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T06CM00930
Permit Description: NEW: DUPLEX R1 - Plumb pipe size change r-2: as built for gas and waste plumbing
Total Completed Inspections - 24
Date Description Inspector Results Comments
05/30/2006 PLUMBING - ROUGH, SOIL BBENEDON Approved IVRS - Inspection :*
WASTE & VENT PIPING W/10' HEAD IS OK
ROUGH PIPING REFLECTS PIPING PLAN FOR UNIT B.
REVISE PLAN TO SHOW ADDITION OF BATHROOM FOR UNIT A.
06/06/2006 PLUMBING - PRE SLAB BBENEDON Approved IVRS - Inspection :*
06/06/2006 BUILDING PRE-SLAB AQUIROZ Approved IVRS - Inspection :*
06/06/2006 EXCAVATION/LAYOUT REBAR & ZON AQUIROZ Approved IVRS - Inspection :*
06/07/2006 ELECTRIC - UFER CCLEMENS Approved IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
NEED MINIMUM #4 COPPER
07/13/2006 ROOF NAILING AQUIROZ Approved IVRS - Inspection :*
07/13/2006 EXT METAL CLIPS/EXT SHEATHING AQUIROZ Approved IVRS - Inspection :*
07/26/2006 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
PROVIDE PLATE STRAPS @ DRYER PRIOR TO SHEETROCK
07/26/2006 ELECTRIC - INTERMEDIATE CCLEMENS Approved IVRS - Inspection :*
OK TO COVER INTERIOR ELECTRICAL AFTER CORRECTIONS
1. INSTALL NAIL PLATES ABOVE PANEL HOMERUNS
2. BOND GAS PIPE TO SERVICE
3. STRAP FEEDERS DOWN WALL INTO SERVICE
4. NEED EXTERIOR REAR RECEPT FOR EACH UNIT.
07/27/2006 PLUMBING - INTERMEDIATE BBENEDON Approved IVRS - Inspection :*
TEST WATER, DWV AND TUBS/SHWRS OK
SAFETY PLATES MISSING AT WATER SERVICE,
PLAN SPECIFIES 1" WATER LINE TO WH
3/4 WATER SERVICE CREATES A RESTRICTION
CORRECT WATER SERVICE SIZE, INSTALL SAFETY PLATES.
OK TO COVER SUBJECT TO PLAN REVISION
RECALL ROUGH AND INTERMEDIATE INSPECTIONS BEFORE FINAL INSPECTION AFTER REVISING PLAN AND SECURING CLOSET FLANGES
07/27/2006 U VALUE FOR WINDOW AQUIROZ Approved IVRS - Inspection :*
07/27/2006 STUCCO MESH AQUIROZ Approved IVRS - Inspection :*
07/31/2006 FRAMING JBURGE Approved IVRS - Inspection :*
08/10/2006 PLUMBING - SEWER HCS CONNECT BBENEDON Approved IVRS - Inspection :*
- 1 1/4 PVC WATER LINE OK
- PLEASE INSTALL HB VAC BREAKERS ON ALL HOSE BIBBS TO PREVENT USE OF UNPROTECTED WATER SUPPLY.
- ABS SEWER OK TO COVER
- TRAFFIC RATED C/O COVERS REQUIRED IN DRIVE
08/10/2006 PLUMBING - YARD WTR LINE/TEST BBENEDON Approved IVRS - Inspection :*
09/22/2006 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
OK TO TILE BATHROOMS
11/27/2006 ELECTRIC - UNDERGROUND RHOLLAND Approved IVRS - Inspection :*
1) LABEL SERVICE FOR NO WATER BOND DUE TO PLASTIC PIPING
2) ID TAPE TO ENCIRCLE CONDUCTOR
11/27/2006 ELECTRIC - TEMPORARY SERVICE RHOLLAND Approved IVRS - Inspection :*
12/27/2006 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :
See detailed listing on site.| 999*
SUPPORT CONDENSATE DRAIN LINES. PAINT PVC WITH LATEX PAINT. PROVIDE A TRAP ON NORTH UNIT.
FINISH CONNECTING GAS & ELEC ON ROOF
12/27/2006 ELECTRIC - FINAL CCLEMENS Approved IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
INSPECTION FOR UNIT #1 ONLY -- CHECK SAME IN OTHER UNIT
1. FINISH ROOFTOP WIRING
2. PROVIDE ARC FAULT PROTECTION FOR SMOKE DETECTORS
3. PANEL DIRECTORY NOT CORRECTLY IDENTIFIED
4. REPLACE CRACKED DEVICES
5. INSTALL ALL BULBS
6. HOOD NEEDS CONNECTOR FOR ROMEX
7. DISHWASHER WIRING NOT COMPLETE
12/28/2006 PLUMBING - FINAL RMYERS Approved IVRS - Inspection :*
PLEASE CALL IN AND HAVE APPROVED ALL REQUIRED INSPECTIONS PRIOR TO CALLING FINAL.
01/02/2007 BUILDING - FINAL AQUIROZ Approved IVRS - Inspection :*
01/04/2007 ELECTRIC - CABLE DROP CCLEMENS Approved IVRS - Inspection :*
01/05/2007 PERMIT FINALED BFLORES Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW