Permit: T06CM00930
Permit Details
Apply Date:
02/14/2006
Applicant:
RUGUONE DAVECUSTOM HOMES INC
Description:
NEW: DUPLEX R1 - Plumb pipe size change r-2: as built for gas and waste plumbing
Contractors:
- RUGUONE DAVECUSTOM HOMES INC
Permit Reviews
Permit Number - T06CM00930
Permit Status: Final
Permit Description: NEW: DUPLEX
R1 - Plumb pipe size change
r-2: as built for gas and waste plumbing
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/04/2007 | REVISION - - 3RD | 01/04/2007 | COMPLETED |
| 02/14/2006 | PLANS OK TO SUBMIT - RES | 02/15/2006 | COMPLETED |
| 02/21/2006 | RESIDENTIAL BLDG/WWM | 03/10/2006 | COMPLETED |
| 04/24/2006 | RESUBMITTAL | 05/05/2006 | COMPLETED |
| 05/17/2006 | RESUBMITTAL | 06/20/2006 | COMPLETED |
| 08/10/2006 | REVISION - - 1ST | 08/10/2006 | COMPLETED |
| 12/26/2006 | REVISION - - 2ND | 12/26/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM00930
Permit Status: Final
Permit Description: NEW: DUPLEX
R1 - Plumb pipe size change
r-2: as built for gas and waste plumbing
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 02/14/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T06CM00930
Permit Description: NEW: DUPLEX
R1 - Plumb pipe size change
r-2: as built for gas and waste plumbing
Total Completed Inspections - 24
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/30/2006 | PLUMBING - ROUGH, SOIL | BBENEDON | Approved | IVRS - Inspection :* WASTE & VENT PIPING W/10' HEAD IS OK ROUGH PIPING REFLECTS PIPING PLAN FOR UNIT B. REVISE PLAN TO SHOW ADDITION OF BATHROOM FOR UNIT A. |
| 06/06/2006 | PLUMBING - PRE SLAB | BBENEDON | Approved | IVRS - Inspection :* |
| 06/06/2006 | BUILDING PRE-SLAB | AQUIROZ | Approved | IVRS - Inspection :* |
| 06/06/2006 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | IVRS - Inspection :* |
| 06/07/2006 | ELECTRIC - UFER | CCLEMENS | Approved | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* NEED MINIMUM #4 COPPER |
| 07/13/2006 | ROOF NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 07/13/2006 | EXT METAL CLIPS/EXT SHEATHING | AQUIROZ | Approved | IVRS - Inspection :* |
| 07/26/2006 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* PROVIDE PLATE STRAPS @ DRYER PRIOR TO SHEETROCK |
| 07/26/2006 | ELECTRIC - INTERMEDIATE | CCLEMENS | Approved | IVRS - Inspection :* OK TO COVER INTERIOR ELECTRICAL AFTER CORRECTIONS 1. INSTALL NAIL PLATES ABOVE PANEL HOMERUNS 2. BOND GAS PIPE TO SERVICE 3. STRAP FEEDERS DOWN WALL INTO SERVICE 4. NEED EXTERIOR REAR RECEPT FOR EACH UNIT. |
| 07/27/2006 | PLUMBING - INTERMEDIATE | BBENEDON | Approved | IVRS - Inspection :* TEST WATER, DWV AND TUBS/SHWRS OK SAFETY PLATES MISSING AT WATER SERVICE, PLAN SPECIFIES 1" WATER LINE TO WH 3/4 WATER SERVICE CREATES A RESTRICTION CORRECT WATER SERVICE SIZE, INSTALL SAFETY PLATES. OK TO COVER SUBJECT TO PLAN REVISION RECALL ROUGH AND INTERMEDIATE INSPECTIONS BEFORE FINAL INSPECTION AFTER REVISING PLAN AND SECURING CLOSET FLANGES |
| 07/27/2006 | U VALUE FOR WINDOW | AQUIROZ | Approved | IVRS - Inspection :* |
| 07/27/2006 | STUCCO MESH | AQUIROZ | Approved | IVRS - Inspection :* |
| 07/31/2006 | FRAMING | JBURGE | Approved | IVRS - Inspection :* |
| 08/10/2006 | PLUMBING - SEWER HCS CONNECT | BBENEDON | Approved | IVRS - Inspection :* - 1 1/4 PVC WATER LINE OK - PLEASE INSTALL HB VAC BREAKERS ON ALL HOSE BIBBS TO PREVENT USE OF UNPROTECTED WATER SUPPLY. - ABS SEWER OK TO COVER - TRAFFIC RATED C/O COVERS REQUIRED IN DRIVE |
| 08/10/2006 | PLUMBING - YARD WTR LINE/TEST | BBENEDON | Approved | IVRS - Inspection :* |
| 09/22/2006 | SHEET ROCK NAILING | JBURGE | Approved | IVRS - Inspection :* OK TO TILE BATHROOMS |
| 11/27/2006 | ELECTRIC - UNDERGROUND | RHOLLAND | Approved | IVRS - Inspection :* 1) LABEL SERVICE FOR NO WATER BOND DUE TO PLASTIC PIPING 2) ID TAPE TO ENCIRCLE CONDUCTOR |
| 11/27/2006 | ELECTRIC - TEMPORARY SERVICE | RHOLLAND | Approved | IVRS - Inspection :* |
| 12/27/2006 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection : See detailed listing on site.| 999* SUPPORT CONDENSATE DRAIN LINES. PAINT PVC WITH LATEX PAINT. PROVIDE A TRAP ON NORTH UNIT. FINISH CONNECTING GAS & ELEC ON ROOF |
| 12/27/2006 | ELECTRIC - FINAL | CCLEMENS | Approved | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* INSPECTION FOR UNIT #1 ONLY -- CHECK SAME IN OTHER UNIT 1. FINISH ROOFTOP WIRING 2. PROVIDE ARC FAULT PROTECTION FOR SMOKE DETECTORS 3. PANEL DIRECTORY NOT CORRECTLY IDENTIFIED 4. REPLACE CRACKED DEVICES 5. INSTALL ALL BULBS 6. HOOD NEEDS CONNECTOR FOR ROMEX 7. DISHWASHER WIRING NOT COMPLETE |
| 12/28/2006 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* PLEASE CALL IN AND HAVE APPROVED ALL REQUIRED INSPECTIONS PRIOR TO CALLING FINAL. |
| 01/02/2007 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection :* |
| 01/04/2007 | ELECTRIC - CABLE DROP | CCLEMENS | Approved | IVRS - Inspection :* |
| 01/05/2007 | PERMIT FINALED | BFLORES | Approved |