Permit: T06CM00815
Permit Details
Status:
Final
Type:
MULTI FAMILY ALTERATION
Address:
1150 N EL DORADO PL #115*
Address NEW:
1150 N EL DORADO PL #115*
Apply Date:
02/08/2006
Applicant:
FLOERCHINGER, MARTIN DEAN
Description:
REMODEL:APARTMENTS TO CONDOS - BLDG 3, Units: #3119, 3120, 3121, 3122, 3124, 3217, 3218, 3219, 3220, 3221, 3222,3223 3224
Contractors:
- T A-WALLICK LLC C*
Permit Reviews
Permit Number - T06CM00815
Permit Status: Final
Permit Description: REMODEL:APARTMENTS TO CONDOS - BLDG 3, Units: #3119, 3120, 3121, 3122, 3124, 3217, 3218, 3219, 3220, 3221, 3222,3223
3224
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/08/2006 | PLANS OK TO SUBMIT - 3RD PARTY | 02/16/2006 | COMPLETED |
| 02/16/2006 | 3RD PARTY REVIEW-COMMERCIAL | 03/23/2006 | COMPLETED |
| 03/23/2006 | POST 3RD PARTY REVIEW | 04/12/2006 | COMPLETED |
| 05/02/2007 | 3RD PARTY REVIEW-REVISION/OTHER | 06/19/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM00815
Permit Status: Final
Permit Description: REMODEL:APARTMENTS TO CONDOS - BLDG 3, Units: #3119, 3120, 3121, 3122, 3124, 3217, 3218, 3219, 3220, 3221, 3222,3223
3224
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 02/08/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T06CM00815
Permit Description: REMODEL:APARTMENTS TO CONDOS - BLDG 3, Units: #3119, 3120, 3121, 3122, 3124, 3217, 3218, 3219, 3220, 3221, 3222,3223
3224
Total Completed Inspections - 22
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/01/2006 | ELECTRIC - ABOVE CEILING | RHOLLAND | Approved | IVRS - Inspection :* 1. SECURE NM CABLE TO BOX. 2. PLEASE VERIFY BOX FILL 3. PROTECT NM CABLES AT STUDS. 4. PANEL NOT ALLOWED IN BATHROOM - NEW CIRCUITS HAVE BEEN ADDED. 5. GFI FOR BATHROOM TO BE 20 AMP CIRCUIT - 210.8 & 210.52 6. HOOD/MICROWAVE TO BE SEPARATE CIRCUIT FOR LOADS. |
| 12/01/2006 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection :* |
| 12/14/2006 | SHEET ROCK NAILING | JBURGE | Approved | IVRS - Inspection :* INFILL SUB-CEILINGS #217, 218, 222, 223, 214 |
| 12/14/2006 | PLUMBING - PRE SLAB | BBENEDON | Approved | IVRS - Inspection :* |
| 12/15/2006 | PLUMBING - INTERMEDIATE | BBENEDON | Approved | IVRS - Inspection :* 3123 OK ALSO |
| 12/28/2006 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE REDUCERS AT CHANGE OF DIAMETER ON EXHAUST DUCTS 2) PROVIDE SCREWS IN ALL CONNECTIONS 3) SECURE CONDENSATE DRAINS 4) BE SURE ALL DRYER VENTS EXTEND BEYOND SHEETROCK |
| 03/28/2007 | BUILDING ABOVE CEILING | JBURGE | Approved | IVRS - Inspection :* |
| 03/28/2007 | U VALUE FOR WINDOW | JBURGE | Approved | IVRS - Inspection :* |
| 03/28/2007 | FRAMING | JBURGE | Approved | IVRS - Inspection :* |
| 03/28/2007 | BUILDING PRE-SLAB | JBURGE | Approved | IVRS - Inspection :* |
| 03/28/2007 | NPPO - FINAL | ACONNOR | Approved | N/A |
| 03/28/2007 | LANDSCAPE - FINAL | ACONNOR | Approved | N/A |
| 03/29/2007 | MECHANICAL - FINAL | JMILITEL | Approved | |
| 03/29/2007 | PLUMBING - ABOVE CEILING | BBENEDON | Approved | IVRS - Inspection :* |
| 03/30/2007 | SIGN - FINAL | JYBARRA | Approved | |
| 03/30/2007 | FIRE - FINAL | CSCHULTZ | Approved | |
| 04/02/2007 | RIGHT OF WAY - FINAL | PWHIDDON | Approved | PER EMAIL |
| 04/02/2007 | ENGINEERING - FINAL | JBRUCKME | Approved | |
| 04/10/2007 | PLUMBING - FINAL | BBENEDON | Approved | IVRS - Inspection :* |
| 04/11/2007 | BUILDING - FINAL | JBURGE | Approved | IVRS - Inspection :* 12 @ UNITS ABOVE; 3217, 3222, 3220, 3224, 3221, 3119, 3122, 3121, 3218, 3223, 3120, 3219 |
| 04/11/2007 | ELECTRIC - CONSTRUCTION POWER | RHOLLAND | Approved | IVRS - Inspection :* |
| 05/02/2007 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection :* |