Permit: T06CM00815

Parcel: 13314460A

Inspection Status: Approved

Inspection History: ELECTRIC - ABOVE CEILING

Date Description Inspector Results Comments
05/02/2007 ELECTRIC - ABOVE CEILING Approved IVRS - Inspection :*
03/05/2007 ELECTRIC - ABOVE CEILING Partial Approval IVRS - Inspection :*
OK CONDUIT REPAIRS
12/01/2006 ELECTRIC - ABOVE CEILING Not ready for Inspection IVRS - Inspection :*
1. SECURE NM CABLE TO BOX.
2. PLEASE VERIFY BOX FILL
3. PROTECT NM CABLES AT STUDS.
4. PANEL NOT ALLOWED IN BATHROOM - NEW CIRCUITS HAVE BEEN ADDED.
5. GFI FOR BATHROOM TO BE 20 AMP CIRCUIT - 210.8 & 210.52
6. HOOD/MICROWAVE TO BE SEPARATE CIRCUIT FOR LOADS.