Permit: T05CM05902
Permit Details
Apply Date:
11/28/2005
Applicant:
CHUCK YOUSEY
Description:
TD #16-48-48 DUPLEX
Contractors:
- SUMNER CONSTRUCTION
Permit Reviews
Permit Number - T05CM05902
Permit Status: Final
Permit Description: TD #16-48-48 DUPLEX
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/28/2005 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 11/30/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM05902
Permit Status: Final
Permit Description: TD #16-48-48 DUPLEX
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/28/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T05CM05902
Permit Description: TD #16-48-48 DUPLEX
Total Completed Inspections - 35
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/09/2005 | PLUMBING - ROUGH, SOIL | BBENEDON | Approved | IVRS - Inspection :* WASTE IN BUILDING OK - CALL FOR WRAPS BEFORE CONCRETE WATER PIPE TO BE ON PLAN - CLEANOUTS |
| 12/12/2005 | PLUMBING - YARD WTR LINE/TEST | BBENEDON | Approved | IVRS - Inspection :* PEX YARD PIPING OK |
| 12/20/2005 | PLUMBING - SEWER HCS CONNECT | BBENEDON | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) SEWER PIPING WAS PARTIALLY APPROVED 12/14/05 2) A JOINT SEWER AGREEMENT IS REQUIRED FOR FINAL APPROVAL 3) A LETTER FROM THE OWNER IS NOT ACCEPTABLE 4) A JOINT SEWER AGREEMENT IS A LEGAL DOCUMENT |
| 12/20/2005 | ELECTRIC - UFER | RMAJUTA | Approved | IVRS - Inspection :*APPROVED |
| 12/27/2005 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | IVRS - Inspection :* 1) MAIN SLAB BLDG OK 2) NEED PORCH AND GARAGE INSPECTED |
| 12/27/2005 | BUILDING PRE-SLAB | AMATHIES | Approved | IVRS - Inspection :* |
| 03/02/2006 | STEM WALL/RETAINING WALL | LHANLY | Approved | IVRS - Inspection :* |
| 03/22/2006 | REINFORCED MASONRY PRE-GROUT | LHANLY | Approved | IVRS - Inspection :* |
| 04/28/2006 | ELECTRIC - CONSTRUCTION POWER | RMAJUTA | Approved | IVRS - Inspection :* |
| 04/28/2006 | ELECTRIC - CABLE DROP | RMAJUTA | Approved | IVRS - Inspection :* |
| 04/28/2006 | ELECTRIC - CONSTRUCTION POWER | RMAJUTA | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1. OUTDOOR PVC NEEDS TO BE SCH 80. 2. STRAP PVC BETWEEN LB & SERVICE. 3. STRAP PVC IN ATTIC. |
| 04/28/2006 | ELECTRIC - CABLE DROP | RMAJUTA | Approved | IVRS - Inspection : See detailed listing on site.| 999* WILL CLEAR ONCE WAIVER APPROVED |
| 05/26/2006 | FRAMING | LHANLY | Approved | IVRS - Inspection :* NEED RFI NEED FIRESTOP |
| 06/01/2006 | U VALUE FOR WINDOW | LHANLY | Approved | IVRS - Inspection :* |
| 06/01/2006 | BUILDING ABOVE CEILING | LHANLY | Approved | IVRS - Inspection :* |
| 06/01/2006 | SHEET ROCK NAILING | LHANLY | Approved | IVRS - Inspection :* |
| 06/16/2006 | STUCCO MESH | AALEGRIA | Approved | IVRS - Inspection :* 1. COMPLETE STUCCO MESH ABOVE CARPORT ON GABLE END. 2. PROVIDE OVERLAP MESH ON WINDOWS. 3. PROVIDE SEALANT AROUND ALL PENETRATIONS ON EXTERIOR WALL & ELECTRICAL PANEL. |
| 07/06/2006 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED FOR UNITS #1 & #2 PER R. MAJUTA |
| 07/11/2006 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection :* REVISED PLAN FROM WILDAN APP. 6/24/06 |
| 07/11/2006 | OUTDOOR LIGHTING FINAL | DSANTACR | Approved | IVRS - Inspection :* |
| 07/11/2006 | ELECTRIC - OUTDOOR LIGHTING | DSANTACR | Approved | IVRS - Inspection :* |
| 07/11/2006 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved | IVRS - Inspection :* |
| 07/11/2006 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection :* |
| 07/11/2006 | ELECTRIC - UNDERGROUND | DSANTACR | Approved | IVRS - Inspection :* |
| 07/11/2006 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection :* |
| 07/12/2006 | PLUMBING - INTERMEDIATE | RLEDONNE | Approved | IVRS - Inspection :* |
| 07/25/2006 | ROOF NAILING | LHANLY | Approved | IVRS - Inspection :* |
| 07/26/2006 | PLUMBING - FINAL | RLEDONNE | Approved | IVRS - Inspection :* |
| 07/27/2006 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection :* |
| 07/28/2006 | PLUMBING - GAS PRESS TEST FNL | RLEDONNE | Approved | |
| 07/28/2006 | SITE - SEWER | RLEDONNE | Approved | |
| 07/28/2006 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | |
| 07/28/2006 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | |
| 07/28/2006 | MECHANICAL - HOODS | CWILLIAM | Approved | |
| 04/04/2007 | PERMIT FINALED | GBONILLA | Approved |