Permit: T05CM05902

Parcel: 129110800


Addresses:

1025 E 24TH ST #01

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
07/12/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
05/31/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
CLOSET FLANGES NOT SET. FLANGES SHALL BE FASTENED TO FLOOR. RE-CALL INTERMEDIATE WHEN READY FOR CLOSET FLANGE INSPECTION.
RECALL HCS AFTER OBTAINING JOINT SEWER AGREEMENT.
05/30/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
- PROVIDE DOCUMENTATION FOR THE USE OF PEX OVER COPPER TUBING.
- PROVIDE 18" OF COPPER BETWEEN SWEAT VALVES & FLEXES AND PEX TUBING.
- PROVIDE PROTECTION OF PEX PASSING THRU METAL STUDS.
- A DOUBLE SANTEE IS NOT ACCEPTABLE AS A DOUBLE FIXTURE FITTING. OVERSIZING OF SANTEE IS FOR BRANCH CONNECTIONS ONLY. SEE UPC ILLUSTRATED TRAINING MANUAL FOR FURTHER EXPLANATION.
- PROVIDE DOUBLE FIXTURE FITTINGS AT LAVS.
- SUPPORT HORIZONTAL WASTE AT LAV OFFSET.
- PROVIDE TEST ON TUB OVERFLOW CONNECTION BEFORE CONCEALING.
- RED LINE PLAN TO SHOW THAT THERE IS NO GAS PIPING.
- GAS FOR GAS INSPECTION TO CLEAR.
05/26/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
GATE LOCKED
PROVIDE ACCESS