Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
COMMERCIAL NEW
Apply Date:
09/29/2005
Applicant:
N/A
Description:
NEW RETAIL BUILDING
Contractors:
  • BARKER MORRISSEY CONTRACTING INC

Permit Reviews

Permit Number - T05CM04982
Permit Status: Expired
Permit Description: NEW RETAIL BUILDING
Start Date Submittal Complete Date Status  
02/01/2006 3RD PARTY REVIEW-REVISION/OTHER 02/08/2006 COMPLETED Review Details
03/01/2006 3RD PARTY REVIEW-REVISION/OTHER 03/03/2006 COMPLETED Review Details
04/13/2006 REVISION - SITE 04/14/2006 COMPLETED Review Details
05/19/2006 REVISION - SITE 05/23/2006 COMPLETED Review Details
09/29/2005 PLANS OK TO SUBMIT - 3RD PARTY 09/29/2005 COMPLETED Review Details
09/29/2005 3RD PARTY REVIEW-COMMERCIAL 12/01/2005 COMPLETED Review Details
11/29/2005 SITE 12/12/2005 COMPLETED Review Details
12/01/2005 POST 3RD PARTY REVIEW 12/20/2005 COMPLETED Review Details
12/12/2005 RESUBMITTAL - SITE 12/20/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05CM04982
Permit Status: Expired
Permit Description: NEW RETAIL BUILDING
Total Outstanding Activity Conditions - 4
Date Name
09/29/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
12/01/2005 SPECIAL INSPECTION FOR CONCRETE IS REQUIRED..
12/01/2005 SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED.
12/01/2005 SPECIAL INSPECTION FOR FOUNDATION/EXCAVATION IS REQUIRED.

Completed Inspections

Permit Status: Expired
Permit Number: T05CM04982
Permit Description: NEW RETAIL BUILDING
Total Completed Inspections - 43
Date Description Inspector Results Comments
01/11/2006 ELECTRIC - UFER RHOLLAND Approved IVRS - Inspection :*OK ?? TO REBAR THRU PVC CONDUIT
03/15/2006 ROOF NAILING JCAGLE Approved IVRS - Inspection :*
03/21/2006 FRAMING JCAGLE Approved IVRS - Inspection :*
04/12/2006 PLUMBING - ROUGH, SOIL RRICH Approved IVRS - Inspection :*
04/12/2006 STUCCO MESH JBURGE Approved IVRS - Inspection :*
04/12/2006 EXT METAL CLIPS/EXT SHEATHING JBURGE Approved IVRS - Inspection :*
04/14/2006 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection :*
04/27/2006 PLUMBING - ROOF DRAINS RRICH Approved IVRS - Inspection :*
WATER TEST ROOF DRAINS OK
05/01/2006 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
05/02/2006 BUILDING ABOVE CEILING JBURGE Approved IVRS - Inspection :*
OK FOR CEILING TILES AFTER MECHANICAL - ELECTRICAL INSPECTION.
05/02/2006 SITE - SEWER RRICH Approved IVRS - Inspection :*
05/02/2006 PLUMBING - SEWER HCS CONNECT RRICH Approved IVRS - Inspection :*
05/10/2006 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
05/10/2006 MECHANICAL - UNDERGROUND JMILITEL Approved IVRS - Inspection :*
05/12/2006 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
OK FOR CEILING TILES.
05/12/2006 SIGN - FINAL JYBARRA Approved BANNERS ARE GONE AT 5 PM; OK FOR C/O
05/12/2006 RIGHT OF WAY - FINAL PWHIDDON Approved PER EMAIL
05/12/2006 SIGN - FINAL JYBARRA Approved IVRS - Inspection : PERMIT OR REMOVE BANNER FOR ACTION DEMO & BARKER/MORRISEY; LEFT MSG ON DAVE #609-8066; The occupancy inspection reveals that corrections are required. Please furni
05/22/2006 PLUMBING - ABOVE CEILING RRICH Approved IVRS - Inspection :*
05/25/2006 EXCAVATION/LAYOUT REBAR & ZON JBURGE Approved IVRS - Inspection :*
LOADING DOCK
05/25/2006 BUILDING PRE-SLAB JBURGE Approved IVRS - Inspection :*
LOADING DOCK
05/30/2006 PLUMBING - FINAL RMYERS Approved IVRS - Inspection :*
1. PLUMBING FINAL OK
OK FOR C OF O
PENDING ANY OTHER INSPECTION
06/14/2006 TEP CLEARANCE - AM JWEATHER Approved TMPP CLEARED PER R. HOLLANDER
06/20/2006 ELECTRIC - FINAL RHOLLAND Approved IVRS - Inspection :*
OK FINAL. C OF O SUBJECT TO COMPLETION OF PERMIT FOR CASH WRAPS & SHELVING.
06/20/2006 ELECTRIC - TEMP POWER FOR TEST RHOLLAND Approved IVRS - Inspection :*
06/20/2006 ELECTRIC - TEMPORARY SERVICE RHOLLAND Approved IVRS - Inspection :*
06/20/2006 ELECTRIC - CABLE DROP RHOLLAND Approved IVRS - Inspection :*
06/20/2006 ELECTRIC - ABOVE CEILING RHOLLAND Approved IVRS - Inspection :*
06/20/2006 ELECTRIC - INTERMEDIATE RHOLLAND Approved IVRS - Inspection :*
06/20/2006 ELECTRIC - UNDERGROUND RHOLLAND Approved IVRS - Inspection :*
06/20/2006 FIRE SPKLR - OH PIPING & HYDRO LTHOMAS Approved
06/20/2006 FIRE SPKLR - UG PIPING FLUSH LTHOMAS Approved
06/20/2006 FIRE SPKLR - UG, PIPING, HYDRO LTHOMAS Approved
06/21/2006 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
OK FOR FINAL
06/21/2006 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
PROVIDE AN AUDIBLE ALARM IN DUCT SMOKE DETECTOR FOR STORAGE AREA.
06/23/2006 FIRE - FINAL LTHOMAS Approved
06/23/2006 FIRE SPKLR - FINAL LTHOMAS Approved
06/29/2006 REINFORCED MASONRY PRE-GROUT JCAGLE Approved
06/29/2006 BUILDING - FINAL JBURGE Approved IVRS - Inspection :*
06/29/2006 STEM WALL/RETAINING WALL JBURGE Approved IVRS - Inspection :*
07/06/2006 ENGINEERING - FINAL DROBERTS Approved ALL PREVIOUSLY NOTED ITEMS COMPLETE AT THIS TIME.
07/07/2006 FIRE - HYDRANTS LTHOMAS Approved
10/27/2006 LANDSCAPE - FINAL ACONNOR Approved

Documents

File Name Document Type  
None CONSTRPLANS VIEW
None DOCUMENTS VIEW