Permit: T05CM04982

Parcel: 13323190A


Addresses:

7810 E SPEEDWAY BL


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T05CM04982

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
06/29/2006 REINFORCED MASONRY PRE-GROUT Approved
02/14/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
WEST COLUMNS 3', 12', 24', 36' S OF N.W. C OF BUILDING
(10'8"-14')
02/13/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*PIERS/VENEER @ NORTH WALL OF BLDG ( 6'-12')
02/10/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
PIERS/VENEER @ NORTH WALL OF BUILDING (0-6')
02/08/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
WEST COLUMNS 3' & 24' S & N.W.C (4'-10'8"); WEST COLUMNS 48', 60', 72' & 84' S OF N.W.C (10'8" - 14'); N WALL OF BUILDING & WALL ABOVE ARCH (22'-27')
02/07/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*WEST EXTERIOR COLUMNS, 0-40' S OF N.W CORNER OF BUILDING ( 0-6')
02/06/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) NORTH WALL OF BLDG, 0-24' W OF S.E.C. (20'-24'); WALL ABOVE CENTER AREA (18'-22'); WEST COLUMNS 48' + 60' S. OF N.W. CORNER OF BLDG (6' 8"-10' 8")
02/03/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH WALL OF BUILDING, 0-24' W OF N.E.C (18'-20'); 24'-52' W OF NEC (20'-22'8"); NORTH WALL 0-24' E & WEST WALL 0-28' S OF N.W. CORNER (20'-24')
02/02/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/01/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH CANOPY COLUMNS (8'-12'); WEST COLUMNS, 48'-96' OF NORTH EAST CORNER OF BUILDING - 4 COLUMNS (0-6')
1. ANCHOR BOLTS MUST BE IN PLACE PRIOR TO PLACEMENT OF CONCRETE. NEED TO VERIFY EMBEDMENT.
2. VERTICAL REINFORCEMENT FOR M3 COLUMNS NEED TO EXTEND TO TOP OF WALL - UNLESS STAMPED LETTER FROM ENGINEER IS PROVIDED STATING OTHERWISE.
NORTH WALL OF BUILDING (14'8"-18'); NORTH COLUMNS/ARCHES, CENTER ARCH (12'-18')
01/31/2006 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
01/29/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*WEST WALL OF BUILDING ( 16'-20')
01/27/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) SOUTH WALL OF BLDG (16'-20')
01/25/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*WEST WALL OF BUILDING
01/24/2006 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
01/23/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) SOUTH WALL OF BLDG (12'-16'); NORTH WALL/COLUMN OF BLDG (8'-10'); NORTH EXTERIOR CANOPY COLUMNS (4'-8')
01/22/2006 REINFORCED MASONRY PRE-GROUT Denied IVRS - Inspection :
See detailed listing on site.| 999*
NO ACCESS TO JOBSITE, GATE LOCKED AND NOBODY ON
SITE @ 1344
01/19/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) WEST WALL, 0-96' S AND N END (8'-12')
01/18/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH EXTERIOR CANOPY COLUMNS (0-4'); WEST WALL/COLUMNS 0-20' S OF N END & NORTH WALL/COLUMNS (4'-8')
01/17/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH WALL/COLUMNS OF BUILDING (0-4"); W. WALL, 0-40' N&S WALL OF BUILDING (8'-12')
01/13/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
WEST WALL, 0-40' N & SOUTH WALL (0-4')
1. NEED COPY OF R.F.I RESPONSE FROM STRUCTURAL ENGINEER FOR EPOXYING OF MISPLACED VERTICAL #6 REBARS @ NORTH SIDE OF BUILDING