Permit: T05CM04555
Permit Details
Apply Date:
09/01/2005
Applicant:
SLADE CONSTRUCTION L L C
Description:
TI: DENTAL OFFICE
Contractors:
- SLADE CONSTRUCTION L L C
Permit Reviews
Permit Number - T05CM04555
Permit Status: C of o
Permit Description: TI: DENTAL OFFICE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/01/2005 | PLANS OK TO SUBMIT - COMM | 09/06/2005 | COMPLETED |
| 09/06/2005 | 3RD PARTY REVIEW-COMMERCIAL TI | 10/12/2005 | COMPLETED |
| 10/12/2005 | POST 3RD PARTY REVIEW | 10/12/2005 | COMPLETED |
| 12/27/2005 | 3RD PARTY REVIEW-REVISION/OTHER | 11/02/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM04555
Permit Status: C of o
Permit Description: TI: DENTAL OFFICE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/01/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T05CM04555
Permit Description: TI: DENTAL OFFICE
Total Completed Inspections - 25
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/18/2005 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection :*SOIL WATER TEST IS OK P.O.C OF NEW BLDG SEWER TO EXSISTING BLDG. SEWER IS OK OK TO BACKFILL TRENCH. |
| 10/18/2005 | ELECTRIC - UNDERGROUND | RSUBA | Approved | IVRS - Inspection :* |
| 10/18/2005 | SITE - SEWER | TRINIVJR | Approved | IVRS - Inspection :* |
| 10/31/2005 | FRAMING | AMATHIES | Approved | IVRS - Inspection :* |
| 11/01/2005 | ELECTRIC - INTERMEDIATE | RSUBA | Approved | IVRS - Inspection :*OK WALLS ONLY |
| 11/02/2005 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | IVRS - Inspection :*ALL CORRECTIONS HAVE BEEN MADE |
| 11/09/2005 | SHEET ROCK NAILING | JCAGLE | Approved | IVRS - Inspection :* |
| 11/23/2005 | PLUMBING - ABOVE CEILING | TRINIVJR | Approved | IVRS - Inspection :* 1) ABOVE CEILING IS OK FOR TILE AND GRID |
| 11/23/2005 | RIGHT OF WAY - FINAL | PWHIDDON | Approved | PER EMAIL |
| 11/23/2005 | MECHANICAL - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection :*SEE 5.1.10.10.6 NFPA99-2005 BRANCH TAKE OFFS SUBJECT TO APPROVAL BY SPECIAL INSPECTOR. OK TO COVER MECH ABOVE CEILING |
| 11/25/2005 | ENGINEERING - FINAL | DROBERTS | Approved | |
| 11/25/2005 | FIRE - FINAL | LTHOMAS | Approved | |
| 11/28/2005 | BUILDING ABOVE CEILING | JCAGLE | Approved | IVRS - Inspection :* |
| 12/08/2005 | MEDICAL GAS - FINAL | RMYERS | Approved | CALL INTERMEDIATE AND FINAL HAVE INITIAL TESTING RESULTS FOR INTERMEDIATE HAVE FINAL RESULTS FOR FINAL |
| 12/08/2005 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
| 12/09/2005 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* 1) A/C 4 OK 2) A/C 1 PROVIDE TRAP ON CONDENSATE DRAIN 3) RTU 1, 2 AND 3 NOT READY 4) OK TEMP C OF O |
| 12/09/2005 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection :* 1) OK TCO IF OTHER INSPECTIONS OK TCO ALSO 2) THRESHOLD AT ENTRANCE MUST MEET ACCESSIBILTY REQUIREMENTS LANDING IS NOT LEVEL 3) SIGN OVER FRONT DOOR "DOOR TO REMAIN UNLOCKED" 4) MENS ROOM VERTICAL GRAB BAR MISSING 5) WOMENS WATER CLOSET TO BE 16"-18" FROM SIDE WALL AND REQUIRES VERT GRAB BAR |
| 12/09/2005 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection :* OK TCO WAITING ON A/C UNIT CALCULATIONS AND DRAWINGS |
| 12/09/2005 | ELECTRIC - ABOVE CEILING | RHOLLAND | Approved | IVRS - Inspection :* |
| 12/10/2005 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection :* PLBG FINAL IS OK OK FOR C OF O |
| 12/12/2005 | MEDICAL - GAS/TEST INTERMED | RMYERS | Approved | IVRS - Inspection :* |
| 12/12/2005 | PLUMBING - MEDICAL GAS/FINAL | RMYERS | Approved | IVRS - Inspection :* |
| 01/17/2006 | TEP CLEARANCE - AM | JKOZUCH | Approved | ECO |
| 04/05/2006 | PERMIT FINALED | LJACKSON | Approved | |
| 04/05/2006 | PLUMBING - SEWER HCS CONNECT | TRINIVJR | Approved | PER PL FINAL |