Permit: T05CM04182
Permit Details
Apply Date:
08/10/2005
Applicant:
HUDSON DESIGN
Description:
STORAGE ROOM
Architects:
- WIER, ROBERT MICHAEL
Contractors:
- HOUSLEY BUILDERS ,
Permit Reviews
Permit Number - T05CM04182
Permit Status: Si_xpire
Permit Description: STORAGE ROOM
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/11/2006 | RESUBMITTAL - SITE ALL | 02/09/2006 | COMPLETED |
01/13/2006 | RESUBMITTAL | 02/09/2006 | COMPLETED |
03/15/2007 | REVISION - SITE | 03/22/2007 | COMPLETED |
03/22/2006 | RESUBMITTAL | 08/03/2006 | COMPLETED |
03/22/2006 | RESUBMITTAL - SITE ALL | 08/03/2006 | COMPLETED |
08/10/2005 | PLANS OK TO SUBMIT - COMM | 08/10/2005 | COMPLETED |
08/10/2005 | PLANS OK TO SUBMIT - SITE | 08/10/2005 | COMPLETED |
08/10/2005 | COMMERCIAL TI | 09/20/2005 | COMPLETED |
08/10/2005 | SITE | 01/11/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM04182
Permit Status: Si_xpire
Permit Description: STORAGE ROOM
Total Outstanding Activity Conditions - 3
Date | Name |
---|---|
08/10/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
01/13/2006 | SPECIAL INSPECTION FORMS AND REPORTS REQUIRED PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY. |
01/13/2006 | SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED. |
Completed Inspections
Permit Status: Si_xpire
Permit Number: T05CM04182
Permit Description: STORAGE ROOM
Total Completed Inspections - 21
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/09/2006 | ELECTRIC - ABOVE CEILING | RSUBA | Approved | IVRS - Inspection :* |
11/09/2006 | ELECTRIC - INTERMEDIATE | RSUBA | Approved | IVRS - Inspection :* |
11/17/2006 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
11/17/2006 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* |
11/17/2006 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* |
11/17/2006 | STEM WALL/RETAINING WALL | GDABBS | Approved | IVRS - Inspection :* STEM WALL AT PLAYGROUND |
11/17/2006 | ELECTRIC - FINAL | RMAJUTA | Approved | IVRS - Inspection :* 1. USE ITE - SIEMENS CK RATHER THAN CRHUSE HINDS. 2. FOR OWNER'S INFORMATION, SUB-PANEL AT REC ROOM THE PANEL DOES NOT HAVE A GROUNDING MEANS THEREFORE YOU CANNOT CONNECT A GROUND SYSTEM TO THIS PANEL THIS WILL HAVE TO BE TAKEN CARE OF FOR FINAL. 3. OUTSIDE LIGHTS PER THIS PLAN NOT INSTALLED YET NOR LIGHTING CONTACTOR ASSEMBLY, WILL NEED FOR FINAL OK TO USE EXISTING LIGHTING UNTIL THEN. 4. FINISH RESTROOM LIGHTING - TEMP C OF O SUBJECT TO ALL LIGHTING IN RESTROOMS FINISHED HAVE GLENN CALL ME 909-5184 |
11/17/2006 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* QUES SIGNS ON SITE TO BE REMOVED OR VARIANCE REQ |
11/17/2006 | PLUMBING - INTERMEDIATE | BBENEDON | Approved | IVRS - Inspection :* |
11/17/2006 | PLUMBING - ROUGH, SOIL | BBENEDON | Approved | IVRS - Inspection :* |
11/17/2006 | BUILDING - FINAL | GDABBS | Approved | IVRS - Inspection :* |
11/17/2006 | FRAMING | GDABBS | Approved | IVRS - Inspection :* |
11/17/2006 | ENGINEERING - FINAL | NKALAHAR | Approved | SITE WORK CONTINUING CONSTRUCTION FENCING STILL IN PLACE EQUIPMENT ON SITE NO OTHER CONCERNS |
11/17/2006 | NPPO - FINAL | ACONNOR | Approved | |
11/17/2006 | LANDSCAPE - FINAL | ACONNOR | Approved | |
11/17/2006 | FIRE - FINAL | LLAKEY | Approved | |
11/18/2006 | RIGHT OF WAY - FINAL | PWHIDDON | Approved | PER EMAIL |
12/05/2006 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/05/2006 | PLUMBING - PROGRESS | RRICH | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
02/28/2007 | ELECTRIC - OUTDOOR LIGHTING | DSANTACR | Approved | IVRS - Inspection :* |
02/28/2007 | SHEET ROCK NAILING | GDABBS | Approved | IVRS - Inspection :* |