Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
DUPLEX NEW
Apply Date:
07/13/2005
Applicant:
GOLDSTEIN CONSTRUCTION MANAGEMEN
Description:
DUPLEX:TD#16-36-37
Contractors:
  • GOLDSTEIN CONSTRUCTION MANAGEMEN

Permit Reviews

Permit Number - T05CM03708
Permit Status: C of o
Permit Description: DUPLEX:TD#16-36-37
Start Date Submittal Complete Date Status  
07/13/2005 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 07/14/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05CM03708
Permit Status: C of o
Permit Description: DUPLEX:TD#16-36-37
Total Outstanding Activity Conditions - 1
Date Name
07/13/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T05CM03708
Permit Description: DUPLEX:TD#16-36-37
Total Completed Inspections - 31
Date Description Inspector Results Comments
12/30/2005 PLUMBING - ROUGH, SOIL BBENEDON Approved IVRS - Inspection :
See detailed listing on site.| 999*WATER TEST DOWN, NOT AT 10'
CHECK LEAKS,
EXPOSE ALL FITTINGS
SUPPORT W.C TRAP ARM TO PROVIDE SLOPE
01/20/2006 ELECTRIC - UFER RSUBA Approved IVRS - Inspection :*
01/22/2006 BUILDING PRE-SLAB JCAGLE Approved IVRS - Inspection :*
04/30/2006 ROOF NAILING JCAGLE Approved IVRS - Inspection :*
05/02/2006 EXCAVATION/LAYOUT REBAR & ZON LHANLY Approved IVRS - Inspection :*
05/02/2006 EXCAVATION/LAYOUT REBAR & ZON LHANLY Approved IVRS - Inspection :
See detailed listing on site.| 999*
07/13/2006 ELECTRIC - ABOVE CEILING RSUBA Approved IVRS - Inspection :*
07/13/2006 ELECTRIC - INTERMEDIATE RSUBA Approved IVRS - Inspection :*
07/13/2006 EXT METAL CLIPS/EXT SHEATHING GDABBS Approved IVRS - Inspection :*
08/03/2006 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
OK FOR SHEETROCK
08/15/2006 STUCCO MESH GDABBS Approved IVRS - Inspection :*
08/15/2006 FRAMING GDABBS Approved IVRS - Inspection :*
08/16/2006 PLUMBING - ABOVE CEILING RRICH Approved IVRS - Inspection :*
08/16/2006 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection :*
09/05/2006 SHEET ROCK NAILING GDABBS Approved IVRS - Inspection :*
11/03/2006 SITE - SEWER RRICH Approved IVRS - Inspection :*
11/07/2006 ELECTRIC - TEMPORARY SERVICE RSUBA Approved IVRS - Inspection :*
11/08/2006 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED FOR UNITS #1 & #2 PER R. SUBA
12/04/2006 PLUMBING - SEWER HCS CONNECT RRICH Approved IVRS - Inspection :*
12/13/2006 PLUMBING - YARD WTR LINE/TEST RRICH Approved IVRS - Inspection :*
REMOVE ALL DEBRIS FROM TRENCH PRIOR TO BACKFILLING WITH GOOD MATERIAL.
12/26/2006 ELECTRIC - FINAL RHOLLAND Approved IVRS - Inspection :*
1. FULLY INSTALL RECEPTACLES & PLATES
2. BOXES MORE THAN 1/4" IN NON-COMBUSTIBLES AND FLUSH IN COMBUSTIBLES NEED AN APPROVED EXTENDER RING 314.20
3. USE AN APPROVED CONNECTOR AT HOOD.
4. SWITCHES TO BE GROUNDED
5. USE APPROVED CORD FOR DISHWASHER -- NOT SPLICED.
6. GROUND METAL BOXES AND USE APPROVED CONNECTORS.
7. HALLWAY SWITCHES NOT WORKING CORRECT.
8. ROOF RECEPTACLES TO BE GFCI PROTECTED
9. TIGHTEN LOOSE FITTINGS
10. MAINTAIN WORKING CLEARANCES IN FRONT OF AC DISCONNECTS
11. USE APPROVED FITTINGS WITH CARFLEX
12. ANTI-ODIDE COMPOUND IS NEEDED FOR ALL ALUMINUM CONDUCTORS.
12/26/2006 MECHANICAL - FINAL GDABBS Approved IVRS - Inspection :*
01/04/2007 ELECTRIC - UNDERGROUND RMAJUTA Approved
01/04/2007 ELECTRIC - CABLE DROP RMAJUTA Approved
01/11/2007 BUILDING - FINAL GDABBS Approved IVRS - Inspection :*
01/12/2007 PERMIT FINALED LJACKSON Approved
01/12/2007 PLUMBING - FINAL RRICH Approved IVRS - Inspection :*
01/12/2007 MECHANICAL - UNDERGROUND GDABBS Approved
01/12/2007 U VALUE FOR WINDOW GDABBS Approved
01/12/2007 BUILDING ABOVE CEILING GDABBS Approved
01/12/2007 STEM WALL/RETAINING WALL GDABBS Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW
None CERT OF OCC VIEW