Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T05CM03708
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/17/2006 | PLUMBING - ROUGH, SOIL | Approved | PIPE WRAPS OK | |
| 01/04/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* WATER TEST UNDERGROUND FROM BUILDING INTERIOR TO 2' PAST 2 WAY CLEANOUT OK NEED TO SEE PIPE WRAPS PRIOR TO CONCRETE & CONTINUATION OF BUILDING SEWER. |
|
| 12/30/2005 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999*WATER TEST DOWN, NOT AT 10' CHECK LEAKS, EXPOSE ALL FITTINGS SUPPORT W.C TRAP ARM TO PROVIDE SLOPE |
|
| 12/29/2005 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999*HAVE APPROVED PLANS ON SITE WITH PERMIT CARD HAVE PLBG. CONTRACTRO FILL WATER TEST MIN. 10' AND BLEED OUT THE AIR. |