Permit: T05CM03555
Permit Details
Apply Date:
07/07/2005
Applicant:
K B HOME OF TUCSON *C
Description:
SFR TD#15-38-44
Contractors:
- K B HOME OF TUCSON *C
Permit Reviews
Permit Number - T05CM03555
Permit Status: Final
Permit Description: SFR TD#15-38-44
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/07/2005 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 07/12/2005 | COMPLETED |
| 08/05/2005 | REVISION - WALK THRU | 08/05/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM03555
Permit Status: Final
Permit Description: SFR TD#15-38-44
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 07/07/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T05CM03555
Permit Description: SFR TD#15-38-44
Total Completed Inspections - 27
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/09/2005 | PLUMBING - SEWER HCS CONNECT | JRIVA | Approved | IVRS - Inspection :* |
| 09/09/2005 | PLUMBING - YARD WTR LINE/TEST | JRIVA | Approved | IVRS - Inspection :* |
| 09/09/2005 | PLUMBING - ROUGH, SOIL | JRIVA | Approved | IVRS - Inspection :* |
| 09/21/2005 | ELECTRIC - UNDERGROUND | JRIVA | Approved | IVRS - Inspection :* |
| 09/21/2005 | ELECTRIC - UFER | JRIVA | Approved | IVRS - Inspection :* |
| 09/21/2005 | BUILDING PRE-SLAB | JRIVA | Approved | IVRS - Inspection :* |
| 09/21/2005 | STEM WALL/RETAINING WALL | JRIVA | Approved | IVRS - Inspection :* |
| 09/21/2005 | EXCAVATION/LAYOUT REBAR & ZON | JRIVA | Approved | IVRS - Inspection :* |
| 11/04/2005 | ROOF NAILING | JRIVA | Approved | IVRS - Inspection :* |
| 11/08/2005 | EXT METAL CLIPS/EXT SHEATHING | JRIVA | Approved | IVRS - Inspection :* |
| 11/17/2005 | ELECTRIC - TEMPORARY SERVICE | CTREVILL | Approved | IVRS - Inspection :* |
| 11/17/2005 | ELECTRIC - CABLE DROP | CTREVILL | Approved | IVRS - Inspection :* |
| 11/18/2005 | TEP CLEARANCE - AM | JKOZUCH | Approved | ECO |
| 12/22/2005 | U VALUE FOR WINDOW | JRIVA | Approved | IVRS - Inspection : There is no plan or job inspection card on site.| 925* |
| 12/22/2005 | STUCCO MESH | JRIVA | Approved | IVRS - Inspection : There is no plan or job inspection card on site.| 925* |
| 12/30/2005 | FRAMING | JRIVA | Approved | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) SEAL FLOOR PENETRATIONS 2) NAIL PROTECT A/C CONDENSATE 3) POWDER ROOM REQUIRES 3" CLEANOUT 4) ELECTRIC OUTLET REQUIRED WITHIN 6' OF STAIR TOP LANDING PONY WALL 5) W/H B-VENT REQUIRES 1" TO COMBUSTIBLE MATERIAL 6) FIRESTOP MASTER BATH 7) PROVIDE LOW ROOF ATTIC ACCESS PER PLAN 8) DBL WALL VENT CANNOT BE IN MECHANICAL CABINET 9) NAIL PROTECT WIRES 10) WIRES TRAPPED BY RANGE 11) TRAP BELOW CEILING 12) PLUMBING OUT OF WALLS 13) REVISE SECOND FLOOR PLUMBING PLAN AND HAVE APPROVED BY CITY FOR AS BUILT 14) STOPPED INSPECTION |
| 12/30/2005 | PLUMBING - GAS PRESSURE TEST | JRIVA | Approved | IVRS - Inspection : Work is not complete enough to inspect.| 950* |
| 12/30/2005 | MECHANICAL - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection : Work is not complete enough to inspect.| 950* |
| 12/30/2005 | PLUMBING - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection : Work is not complete enough to inspect.| 950* |
| 12/30/2005 | ELECTRIC - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection : Work is not complete enough to inspect.| 950* |
| 01/24/2006 | SHEET ROCK NAILING | CTREVILL | Approved | IVRS - Inspection :* |
| 03/15/2006 | MECHANICAL - FINAL | JRIVA | Approved | IVRS - Inspection :* |
| 03/15/2006 | PLUMBING - FINAL | JRIVA | Approved | IVRS - Inspection :* |
| 03/15/2006 | ELECTRIC - FINAL | JRIVA | Approved | IVRS - Inspection :* |
| 03/15/2006 | BUILDING - FINAL | JRIVA | Approved | IVRS - Inspection :* |
| 03/15/2006 | PLUMBING - GAS PRESS TEST FNL | JRIVA | Approved | IVRS - Inspection :* |
| 09/18/2006 | PERMIT FINALED | LJACKSON | Approved |