Permit: T05CM03555

Parcel: 140378180


Addresses:

6775 S AQUILINE DR

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
03/15/2006 BUILDING - FINAL Approved IVRS - Inspection :*
03/08/2006 BUILDING - FINAL Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) PROVIDE 2 SEWER CLEANOUTS-DO NOT COVER REPAIR
2) PROVIDE 4" CLEARANCE BETWEEN WEEP SCREED AND SOIL
3) PROVIDE 1/4" GRILL FOR EXHAUST FAN
4) A/C CONDENSOR NOT 3" ABOVE GRADE
5) A/C CONDENSOR NOT POWER CONNECTED
6) OUTISDE REAR GFCI LOOSE AND NOT SEALED TO WEATHER
7) STOPPED INSPECTION-TOO MANY ITEMS