Permit: T05CM03555

Parcel: 140378180


Addresses:

6775 S AQUILINE DR

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
11/08/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
11/04/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NORTH SECOND FLOOR SILL PLATE NOT FULL BEARING
2) 20 SD4 CANNOT USE TICO NAILS
11/02/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) RIBBON SHEAR NOT NAILED
2) 7/SD3 REQUIRED AT 64" ON CENTER
3) REAR 2ND FLOOR P-1 MUST BE 8 FT
4) BLOCK AND NAIL FRONT #1 SHEAR
5) 20/SD4 NOT DONE
6) OSB ROOF SHEATHING MUST BE INSTALLED WITH LONG DIMENSION ACROSS TRUSSES