Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/08/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 11/04/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NORTH SECOND FLOOR SILL PLATE NOT FULL BEARING 2) 20 SD4 CANNOT USE TICO NAILS |
|
| 11/02/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) RIBBON SHEAR NOT NAILED 2) 7/SD3 REQUIRED AT 64" ON CENTER 3) REAR 2ND FLOOR P-1 MUST BE 8 FT 4) BLOCK AND NAIL FRONT #1 SHEAR 5) 20/SD4 NOT DONE 6) OSB ROOF SHEATHING MUST BE INSTALLED WITH LONG DIMENSION ACROSS TRUSSES |