Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/12/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 01/11/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS 7, 8 AND 10 OF PRIOR INSPECTION NOT DONE 2) FIRE STOP WATER HEATER B-VENT |
|
| 12/30/2005 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) SEAL FLOOR PENETRATIONS 2) NAIL PROTECT A/C CONDENSATE 3) POWDER ROOM REQUIRES 3" CLEANOUT 4) ELECTRIC OUTLET REQUIRED WITHIN 6' OF STAIR TOP LANDING PONY WALL 5) W/H B-VENT REQUIRES 1" TO COMBUSTIBLE MATERIAL 6) FIRESTOP MASTER BATH 7) PROVIDE LOW ROOF ATTIC ACCESS PER PLAN 8) DBL WALL VENT CANNOT BE IN MECHANICAL CABINET 9) NAIL PROTECT WIRES 10) WIRES TRAPPED BY RANGE 11) TRAP BELOW CEILING 12) PLUMBING OUT OF WALLS 13) REVISE SECOND FLOOR PLUMBING PLAN AND HAVE APPROVED BY CITY FOR AS BUILT 14) STOPPED INSPECTION |
|
| 12/22/2005 | FRAMING | Denied | IVRS - Inspection : There is no plan or job inspection card on site.| 925* 1) HORIZONTAL DWV DRAIN MUST HAVE 1/4" PER FT PITCH 2) TOILET NOT PROPERLY VENTED 3) SEAL FLOOR PENETRATIONS 4) FIREBLOCK CHASES 5) 2015 HOUSE 1634 PLAN 6) STOPPED INSPECTION 7) NO PLAN ON SITE |