Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
4656 E 1ST ST
Address NEW:
4656 E 1ST ST
Apply Date:
06/24/2005
Applicant:
PHIL CARHUFF
Description:
BAR/RESTAURANT : FIRE DAMAGE RESTORTION
Contractors:
  • T M BUILDING AND DEVELOPMENT INC

Permit Reviews

Permit Number - T05CM03101
Permit Status: C of o
Permit Description: BAR/RESTAURANT : FIRE DAMAGE RESTORTION
Start Date Submittal Complete Date Status  
06/24/2005 PLANS OK TO SUBMIT - COMM 08/17/2005 COMPLETED Review Details
07/05/2006 3RD PARTY REVIEW-REVISION/OTHER 07/14/2006 COMPLETED Review Details
08/15/2006 OTHER 08/15/2006 COMPLETED Review Details
08/18/2005 3RD PARTY REVIEW-COMMERCIAL 10/04/2005 COMPLETED Review Details
10/04/2005 POST 3RD PARTY REVIEW 10/12/2005 COMPLETED Review Details
12/06/2006 3RD PARTY REVIEW-REVISION/OTHER 12/08/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05CM03101
Permit Status: C of o
Permit Description: BAR/RESTAURANT : FIRE DAMAGE RESTORTION
Total Outstanding Activity Conditions - 1
Date Name
06/24/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T05CM03101
Permit Description: BAR/RESTAURANT : FIRE DAMAGE RESTORTION
Total Completed Inspections - 33
Date Description Inspector Results Comments
12/23/2005 REINFORCED MASONRY PRE-GROUT JCAGLE Approved IVRS - Inspection :*N.W CORNER OF BINGO HALL ( 4" -8") INFILL & DOOR REPLACEMENT @ BURN AREA
01/11/2006 ROOF NAILING JCAGLE Approved IVRS - Inspection :*
01/25/2006 MECHANICAL - PROGRESS JMILITEL Approved IVRS - Inspection :*
DUCT IN SOFFIT WILL REQUIRE MIN R5 INSULATION.
KITCHEN HOOD & EXHAUST DUCT DO NO MEET TYPE 1 REQUIREMENTS OR CLEARANCES.
OK FOR SHEET ROCK 3 ROOMS WEST END
01/31/2006 ELECTRIC - INTERMEDIATE RHOLLAND Approved IVRS - Inspection :*
1) OK ROUGH ELECTRIC
02/09/2006 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection :*
03005 - FLOOR SINK IS EXISTING AT (3) LOCATIONS (1) HAS BEEN DEMEED OUT. ADDITION OF DETAIL 3 NOT REQUIRED PER CONTRACTOR.
03035 - WATER PIPING PER DETAIL #2 (OK) 3/4" IS SUPPLY TO WATER HEATER PER CODE REQUIREMENTS.
04/03/2006 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
04/06/2006 FRAMING JBURGE Approved IVRS - Inspection :*
1. RECEIVED LETTER FROM ARCHITECT CONCERNING EPOXY BOLTS.
2. OK TO SHEETROCK.
04/12/2006 ELECTRIC - ABOVE CEILING RMAJUTA Approved IVRS - Inspection :*
APPROVED AS PER REJECTION LISTED BELOW
NOTE GUTTER BELOW CEILING
1. GUTTER IN STORAGE ROOM - SE CORNER OF BLDG APPEARS TO HAVE OVER ALLOWED 30 CURRENT CARRYING CONDUCTOR FALLING INTO TABLE 310-15 B-2 FOR DERATING 31-45 CURRENT CARRYING CONDUCTORS AT 35%.
2. THE GUTTER IS UNAPPROVED IT'S IN TWO SECTIONS AND NOT COUPLED WITH A LISTED RING.
3. GUTTER REQUIRED TO BE BONDED TO EQUIPMENT GRID.
04/12/2006 BUILDING ABOVE CEILING JBURGE Approved IVRS - Inspection :*
BLOCK & SECURE DUCT WORK @ W & SW CEILING AREA
05/02/2006 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
10/18/2006 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
OK TO FIRE WRAP GREASE DUCT. WRAP TO EXTEND FULL LENGTH OF DUCT. LEAVE CURB OPEN ON ROOF TO INSPECT FIRE WRAP. OK TO SHEETROCK KITCHEN.
11/03/2006 ELECTRIC - FINAL RHOLLAND Approved IVRS - Inspection :*
11/03/2006 ELECTRIC - PROGRESS RHOLLAND Approved IVRS - Inspection :*
12/14/2006 PLUMBING - FINAL RRICH Approved IVRS - Inspection :*
12/14/2006 PLUMBING - PROGRESS RRICH Approved IVRS - Inspection :*
12/14/2006 PLUMBING - GAS PRESS TEST FNL RRICH Approved IVRS - Inspection :*
12/14/2006 PLUMBING - GAS PRESSURE TEST RRICH Approved IVRS - Inspection :*
12/14/2006 BUILDING - FINAL JBURGE Approved IVRS - Inspection :*
12/14/2006 BUILDING - PROGRESS JBURGE Approved IVRS - Inspection :*
12/15/2006 OUTDOOR LIGHTING FINAL RHOLLAND Approved
12/15/2006 PLUMBING - ROUGH, SOIL RRICH Approved
12/15/2006 PLUMBING - YARD WTR LINE/TEST RRICH Approved
12/15/2006 PLUMBING - SEWER HCS CONNECT RRICH Approved
12/15/2006 ELECTRIC - CONSTRUCTION POWER RHOLLAND Approved
12/15/2006 ELECTRIC - OUTDOOR LIGHTING RHOLLAND Approved
12/18/2006 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
12/20/2006 MECHANICAL - HOOD SYSTEMS JMILITEL Approved
12/20/2006 MECHANICAL - HOODS JMILITEL Approved
12/20/2006 FIRE - FINAL LLAKEY Approved
12/20/2006 FIRE - KITCHEN EXH HOOD FINAL LLAKEY Approved
12/20/2006 SIGN - FINAL JYBARRA Approved IVRS - Inspection :*
12/21/2006 PERMIT FINALED LJACKSON Approved
12/21/2006 ENGINEERING - FINAL MRUSSO Approved

Documents

File Name Document Type  
None CERT OF OCC VIEW
T05CM03101.PDF DOCUMENTS VIEW
None DOCUMENTS VIEW