Permit: T05CM03101
Permit Details
Apply Date:
06/24/2005
Applicant:
PHIL CARHUFF
Description:
BAR/RESTAURANT : FIRE DAMAGE RESTORTION
Contractors:
- T M BUILDING AND DEVELOPMENT INC
Permit Reviews
Permit Number - T05CM03101
Permit Status: C of o
Permit Description: BAR/RESTAURANT : FIRE DAMAGE RESTORTION
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/24/2005 | PLANS OK TO SUBMIT - COMM | 08/17/2005 | COMPLETED |
| 07/05/2006 | 3RD PARTY REVIEW-REVISION/OTHER | 07/14/2006 | COMPLETED |
| 08/15/2006 | OTHER | 08/15/2006 | COMPLETED |
| 08/18/2005 | 3RD PARTY REVIEW-COMMERCIAL | 10/04/2005 | COMPLETED |
| 10/04/2005 | POST 3RD PARTY REVIEW | 10/12/2005 | COMPLETED |
| 12/06/2006 | 3RD PARTY REVIEW-REVISION/OTHER | 12/08/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM03101
Permit Status: C of o
Permit Description: BAR/RESTAURANT : FIRE DAMAGE RESTORTION
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/24/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T05CM03101
Permit Description: BAR/RESTAURANT : FIRE DAMAGE RESTORTION
Total Completed Inspections - 33
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/23/2005 | REINFORCED MASONRY PRE-GROUT | JCAGLE | Approved | IVRS - Inspection :*N.W CORNER OF BINGO HALL ( 4" -8") INFILL & DOOR REPLACEMENT @ BURN AREA |
| 01/11/2006 | ROOF NAILING | JCAGLE | Approved | IVRS - Inspection :* |
| 01/25/2006 | MECHANICAL - PROGRESS | JMILITEL | Approved | IVRS - Inspection :* DUCT IN SOFFIT WILL REQUIRE MIN R5 INSULATION. KITCHEN HOOD & EXHAUST DUCT DO NO MEET TYPE 1 REQUIREMENTS OR CLEARANCES. OK FOR SHEET ROCK 3 ROOMS WEST END |
| 01/31/2006 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection :* 1) OK ROUGH ELECTRIC |
| 02/09/2006 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection :* 03005 - FLOOR SINK IS EXISTING AT (3) LOCATIONS (1) HAS BEEN DEMEED OUT. ADDITION OF DETAIL 3 NOT REQUIRED PER CONTRACTOR. 03035 - WATER PIPING PER DETAIL #2 (OK) 3/4" IS SUPPLY TO WATER HEATER PER CODE REQUIREMENTS. |
| 04/03/2006 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* |
| 04/06/2006 | FRAMING | JBURGE | Approved | IVRS - Inspection :* 1. RECEIVED LETTER FROM ARCHITECT CONCERNING EPOXY BOLTS. 2. OK TO SHEETROCK. |
| 04/12/2006 | ELECTRIC - ABOVE CEILING | RMAJUTA | Approved | IVRS - Inspection :* APPROVED AS PER REJECTION LISTED BELOW NOTE GUTTER BELOW CEILING 1. GUTTER IN STORAGE ROOM - SE CORNER OF BLDG APPEARS TO HAVE OVER ALLOWED 30 CURRENT CARRYING CONDUCTOR FALLING INTO TABLE 310-15 B-2 FOR DERATING 31-45 CURRENT CARRYING CONDUCTORS AT 35%. 2. THE GUTTER IS UNAPPROVED IT'S IN TWO SECTIONS AND NOT COUPLED WITH A LISTED RING. 3. GUTTER REQUIRED TO BE BONDED TO EQUIPMENT GRID. |
| 04/12/2006 | BUILDING ABOVE CEILING | JBURGE | Approved | IVRS - Inspection :* BLOCK & SECURE DUCT WORK @ W & SW CEILING AREA |
| 05/02/2006 | SHEET ROCK NAILING | JBURGE | Approved | IVRS - Inspection :* |
| 10/18/2006 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* OK TO FIRE WRAP GREASE DUCT. WRAP TO EXTEND FULL LENGTH OF DUCT. LEAVE CURB OPEN ON ROOF TO INSPECT FIRE WRAP. OK TO SHEETROCK KITCHEN. |
| 11/03/2006 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection :* |
| 11/03/2006 | ELECTRIC - PROGRESS | RHOLLAND | Approved | IVRS - Inspection :* |
| 12/14/2006 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :* |
| 12/14/2006 | PLUMBING - PROGRESS | RRICH | Approved | IVRS - Inspection :* |
| 12/14/2006 | PLUMBING - GAS PRESS TEST FNL | RRICH | Approved | IVRS - Inspection :* |
| 12/14/2006 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection :* |
| 12/14/2006 | BUILDING - FINAL | JBURGE | Approved | IVRS - Inspection :* |
| 12/14/2006 | BUILDING - PROGRESS | JBURGE | Approved | IVRS - Inspection :* |
| 12/15/2006 | OUTDOOR LIGHTING FINAL | RHOLLAND | Approved | |
| 12/15/2006 | PLUMBING - ROUGH, SOIL | RRICH | Approved | |
| 12/15/2006 | PLUMBING - YARD WTR LINE/TEST | RRICH | Approved | |
| 12/15/2006 | PLUMBING - SEWER HCS CONNECT | RRICH | Approved | |
| 12/15/2006 | ELECTRIC - CONSTRUCTION POWER | RHOLLAND | Approved | |
| 12/15/2006 | ELECTRIC - OUTDOOR LIGHTING | RHOLLAND | Approved | |
| 12/18/2006 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
| 12/20/2006 | MECHANICAL - HOOD SYSTEMS | JMILITEL | Approved | |
| 12/20/2006 | MECHANICAL - HOODS | JMILITEL | Approved | |
| 12/20/2006 | FIRE - FINAL | LLAKEY | Approved | |
| 12/20/2006 | FIRE - KITCHEN EXH HOOD FINAL | LLAKEY | Approved | |
| 12/20/2006 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
| 12/21/2006 | PERMIT FINALED | LJACKSON | Approved | |
| 12/21/2006 | ENGINEERING - FINAL | MRUSSO | Approved |