Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/14/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 11/06/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 3-COMP SINK SHALL HAVE SEPARATE DRAINAGE FOR SANITIZE BOWL FROM WASH & RINSE BOWLS. OPEN FRONT SEATS REQUIRED FOR PUBLIC USE STOOLS. |
|
| 11/03/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. CALL IN ALL PLUMBING INSPECTIONS THAT HAVE NOT BEEN APPROVED. 2. SUPPORT EXPANSION TANK AT WATER HEATER. 3. ALL FIXTURES TO BE FUNCTIONAL. 4. SEE NOTES FROM PAST INSPECTIONS & COMPLY. |
|
| 10/10/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* SUPPORT INDIRECT WASTE PIPING AT BEER STATION. ICE MAKER NOT INSTALLED GAS PSI 0, BONDING NOT ATTACHED TO PIPE. HOLE IN EVE. EXISTING RESTROOMS, URINALS MISSING VACUUM BREAKERS ALSO, SOME LEAKS EXIST. TUBULAR BRASS P TRAPS NOT ALLOWED ON URINALS. WATER CLOSETS NOT CAULKED TO FLOOR. NEW PUBLIC USE LAVITORY REQUIRES TEMPERING VALVE. WH IN BAR NOT WIRED PROPERLY & REQUIRES EXPANSION TANK. APPROVED PLUMBING DRAWING NOT ON SITE. HC RESTROOM NOT PER PLAN. |
|
| 09/07/2006 | PLUMBING - FINAL | Partial Approval | EXISTING RESTROOMS AT SOUTH WEST CORNER AND FUNCTIONAL (NO ADA) NO PROBLEM FOR USE AS 1 DAY VOTING AREA | |
| 09/07/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* EXISTING RESTROOMS AT SOUTHWEST CORNER ARE FUNCTIONAL (NO ADA) NO PROBLEM FOR USE AS 1 DAY VOTING AREA. |