Permit: T05CM00742
Permit Details
Apply Date:
02/18/2005
Applicant:
SCOTT HARDEN
Description:
RENOVATION: GYM TO SELF STORAGE UNITS
Contractors:
- HAZEN LTD , STEVE
Permit Reviews
Permit Number - T05CM00742
Permit Status: C of o
Permit Description: RENOVATION: GYM TO SELF STORAGE UNITS
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/09/2007 | SITE | 01/10/2007 | COMPLETED |
02/18/2005 | PLANS OK TO SUBMIT - COMM | 05/27/2005 | COMPLETED |
03/08/2006 | RESUBMITTAL | 03/20/2006 | COMPLETED |
05/27/2005 | 3RD PARTY REVIEW-COMMERCIAL TI | 08/29/2005 | COMPLETED |
08/29/2005 | POST 3RD PARTY REVIEW | 03/08/2006 | COMPLETED |
09/19/2006 | 3RD PARTY REVIEW-REVISION/OTHER | 09/21/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM00742
Permit Status: C of o
Permit Description: RENOVATION: GYM TO SELF STORAGE UNITS
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
02/18/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T05CM00742
Permit Description: RENOVATION: GYM TO SELF STORAGE UNITS
Total Completed Inspections - 33
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/18/2006 | EXT METAL CLIPS/EXT SHEATHING | GDABBS | Approved | IVRS - Inspection :* EAST END INT. BLDG. 10 SHEAR WALLS OK |
07/18/2006 | PLUMBING - ROUGH, SOIL | RRICH | Approved | IVRS - Inspection :* |
09/12/2006 | BUILDING PRE-SLAB | GDABBS | Approved | ELEVATOR PIT PRE-SLAB FLOOR |
09/12/2006 | PLUMBING - INTERMEDIATE | BBENEDON | Approved | AT RESTROOMS: DCW INSTALLED PER REVISION 3 OF 9/6/06 HAVE REVISED PLANS APPROVED. OTHER CORRECTION NOT YET COMPLETED |
09/12/2006 | PLUMBING - ABOVE CEILING | BBENEDON | Approved | |
09/26/2006 | STEM WALL/RETAINING WALL | GDABBS | Approved | IVRS - Inspection :* 1ST LIFT CMU @ ELEVATOR SHAFT & ELECTRICAL ROOM |
10/04/2006 | EXCAVATION/LAYOUT REBAR & ZON | GDABBS | Approved | H/C RAMP @ NORTH ENTRANCE |
10/31/2006 | REINFORCED MASONRY PRE-GROUT | GDABBS | Approved | IVRS - Inspection :* TOP OUT OF CMU AT ELEVATOR SHAFT & ELECTRICAL ROOM |
10/31/2006 | FRAMING | GDABBS | Approved | IVRS - Inspection :* ENTRY CANOPY ELEVATOR SHAFT ROOFING, SECOND FL. ENTRY CANOPY AND WEST DELIVERY CANOPY FRAMING OK |
10/31/2006 | ROOF NAILING | GDABBS | Approved | IVRS - Inspection :* ENTRY CANOPY ROOFING |
11/14/2006 | SHEET ROCK NAILING | GDABBS | Approved | IVRS - Inspection :* WEST ENTRY RATED WALLS ELEVATOR SHAFT ELEVATOR EQUIP. ROOM RATED CEILING & RATED WALL & CEILING AT STAIRWELL - WEST. |
11/16/2006 | STUCCO MESH | GDABBS | Approved | IVRS - Inspection :* |
11/17/2006 | ELECTRIC - INTERMEDIATE | RMAJUTA | Approved | IVRS - Inspection :* 1. OFFICE CEILING OK 2. DISPLAY AREA OK CEILING |
11/17/2006 | ELECTRIC - ABOVE CEILING | RMAJUTA | Approved | IVRS - Inspection :* |
12/08/2006 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* SUSPENDED ROUGH DUCT ROOFTOP WORK PROGRESSING NO CONDENSATE ONTO HARD SURFACES |
12/28/2006 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE COVERS OVER CANVAS CONNECTORS 2) FINISH MARKING DATA PLATES 3) PROVIDE FRESH AIR INTAKES 4) PROVIDE SLEEPERS 5) PERMANENTLY IDENTIFY UNITS ON ROOF 6) PLANS REQUIRE DUCT SMOKE DETECTORS IN 5 TON UNITS. PROVIDE LETTER FROM ENGINEER IF DELETING 7) CONNECT OVERFLOW SENSOR ON CONDENSATE PUMP 8) PROVIDE SPECS FOR CONDENSATE PUMP |
12/29/2006 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection :* 1) SUPPORT VDV CABELING ABOVE GRID PER 725.6 AND 800.6 |
12/29/2006 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
01/02/2007 | RIGHT OF WAY - FINAL | SDAMRON | Approved | PER EMAIL |
01/02/2007 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
01/02/2007 | ELECTRIC - OUTDOOR LIGHTING | RHOLLAND | Approved | IVRS - Inspection :* |
01/02/2007 | ELECTRIC - TEMP POWER FOR TEST | RHOLLAND | Approved | IVRS - Inspection :* |
01/03/2007 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | |
01/03/2007 | FIRE SPKLR - UG PIPING FLUSH | LTHOMAS | Approved | |
01/03/2007 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | |
01/03/2007 | FIRE - FINAL | LTHOMAS | Approved | |
01/09/2007 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :* |
01/17/2007 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* |
01/17/2007 | ENGINEERING - FINAL | NKALAHAR | Approved | SITE MATCHES SITE PLAN |
01/19/2007 | BUILDING - FINAL | GDABBS | Approved | IVRS - Inspection :* #01005, #01010, #01015, #01025, #01030, #01035, #01036, #01040, #01041, #01045 APPROVED |
01/19/2007 | U VALUE FOR WINDOW | GDABBS | Approved | IVRS - Inspection :* |
01/19/2007 | BUILDING ABOVE CEILING | GDABBS | Approved | IVRS - Inspection :* |
01/22/2007 | PERMIT FINALED | BFLORES | Approved |