Permit Details

Status:
Final
Type:
COMMERCIAL ALTERATION
Apply Date:
02/09/2005
Applicant:
J R TUTTLE CO
Description:
TI:RETAIL
Contractors:
  • J R TUTTLE CO

Permit Reviews

Permit Number - T05CM00567
Permit Status: Final
Permit Description: TI:RETAIL
Start Date Submittal Complete Date Status  
02/09/2005 PLANS OK TO SUBMIT - 3RD PARTY 02/10/2005 COMPLETED Review Details
02/10/2005 PLANS OK TO SUBMIT - SITE 02/10/2005 COMPLETED Review Details
02/10/2005 3RD PARTY REVIEW-COMMERCIAL TI 03/16/2005 COMPLETED Review Details
02/10/2005 SITE 03/16/2005 COMPLETED Review Details
03/16/2005 POST 3RD PARTY REVIEW 03/24/2005 COMPLETED Review Details
03/17/2005 RESUBMITTAL - SITE 03/24/2005 COMPLETED Review Details
03/24/2005 RESUBMITTAL 03/30/2005 COMPLETED Review Details
03/24/2005 RESUBMITTAL - SITE 03/30/2005 COMPLETED Review Details
06/22/2005 REVISION 07/13/2005 COMPLETED Review Details
09/13/2005 3RD PARTY REVIEW-REVISION/OTHER 09/13/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05CM00567
Permit Status: Final
Permit Description: TI:RETAIL
Total Outstanding Activity Conditions - 1
Date Name
02/09/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T05CM00567
Permit Description: TI:RETAIL
Total Completed Inspections - 31
Date Description Inspector Results Comments
04/28/2005 ELECTRIC - TEMPORARY SERVICE RSUBA Approved IVRS - Inspection :*
06/20/2005 STEM WALL/RETAINING WALL LHANLY Approved IVRS - Inspection :*
07/05/2005 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection :*
1) AT SINK AND MOP SINK LOCATION P-6 P-7 CONTRACTOR TO INSTALL FLOOR CLEANOUT. HORIZONTAL CHANGE OF DIRECTION EXCEEDING 135 DEGREE REQUIRES CLEAN-OUT. WILL CHECK ON INTERMEDIATE
2) OK TO COVER
3) BATHROOM ROUGH-IN UNDER SLAB OK WATER TEST ONE RISER TO TEN FEET OK-OK TO COVER
07/15/2005 BUILDING PRE-SLAB LHANLY Approved IVRS - Inspection :* 1-7/A-C OK FOR CONCRETE SLAB.
07/29/2005 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection :*
1) WASTE AND VENT WATER TEST THRU ROOF CORRECTION MADE OK
07/29/2005 TEP CLEARANCE - AM HLEYVA Approved ECO CLEARED BY SUBA
08/03/2005 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
08/04/2005 ELECTRIC - TEMP POWER FOR TEST RMAJUTA Approved OK ECO PER SUBA
08/05/2005 ELECTRIC - INTERMEDIATE RSUBA Approved IVRS - Inspection :*
08/31/2005 ELECTRIC - ABOVE CEILING RSUBA Approved IVRS - Inspection :*
09/06/2005 BUILDING ABOVE CEILING LHANLY Approved IVRS - Inspection :*
SOFFIT OK
09/06/2005 RIGHT OF WAY - FINAL DLEE Approved PER EMAIL
09/06/2005 SIGN - FINAL RDEAR Approved IVRS - Inspection :*
09/06/2005 SHEET ROCK NAILING LHANLY Approved IVRS - Inspection :*
09/13/2005 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
09/16/2005 FIRE - HYDRANTS LTHOMAS Approved
09/22/2005 REINFORCED MASONRY PRE-GROUT LHANLY Approved IVRS - Inspection :*
09/29/2005 EXCAVATION/LAYOUT REBAR & ZON LHANLY Approved IVRS - Inspection :*
09/29/2005 FRAMING LHANLY Approved IVRS - Inspection :*
09/29/2005 STUCCO MESH LHANLY Approved IVRS - Inspection :*
10/05/2005 PLUMBING - FINAL RRICH Approved IVRS - Inspection :*BLD INSPECTOR TO VIEW NORTH CENTER ROOF CORRECTION TO ROOF FOR RAIN DRAINAGE
10/05/2005 PLUMBING - ROOF DRAINS RRICH Approved IVRS - Inspection :*
10/05/2005 PLUMBING - ABOVE CEILING RRICH Approved IVRS - Inspection :*
10/11/2005 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :* DUCT DETECTORS HAVE BEEN TESTED
PERMANENTLY IDENTIFY UNITS & DATA PLATES.
WILL CHECK ON PHASE 2
OK FOR FINAL C OF O
10/11/2005 ENGINEERING - FINAL DROBERTS Approved TEMPORARY C OF O FOR OCCUPANCY. FINAL NOT TO BE GIVEN UNTIL ALL EXTERIOR WORK IS COMPLETE.
10/11/2005 U VALUE FOR WINDOW LHANLY Approved IVRS - Inspection :*
10/11/2005 FIRE SPKLR - FINAL LTHOMAS Approved Approval for existing retail area only.
10/11/2005 FIRE - FINAL LTHOMAS Approved Approval to occupy existing retail only.
10/13/2005 BUILDING - FINAL LHANLY Approved IVRS - Inspection :*
1) NO PERMANENT ADDRESS POSTED
2) NO ACCESSIBLE PARKING
3) ACCESSIBLE ROUTE OUT OF BLDG DOES NOT COMPLY WITH ANSI SECTION 705
4) PROVIDE ELECTRIC FINAL INSPECTION REPORT
5) PROVIDE FINAL INSP. REPORTS FROM AL LOT O INSPECTORS
6) SIGNAGE REQUIRED AT MAIN ENTRANCE DOORS "DOORS TO REMAIN UNLOCKED WHILE BLDG IS OCCUPIED"
7) ACCESSIBILITY SIGNAGE FOR RESTROOMS TO BE ON WALL AT LATCH SIDE OF DOOR
8) EXIT DOORS MUST UNLOCK FROM EGRESS SIDE
9) NOT OK FOR TCO
10/13/2005 LANDSCAPE - FINAL ACONNOR Approved OK for Temp. C of O
12/20/2005 ELECTRIC - FINAL RSUBA Approved IVRS - Inspection :*APPROVED