Permit: T05CM00051
Permit Details
Apply Date:
01/05/2005
Applicant:
I D C
Description:
NEW:FOURPLEX
Contractors:
- KEY HOMES
Permit Reviews
Permit Number - T05CM00051
Permit Status: Expired
Permit Description: NEW:FOURPLEX
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/05/2005 | PLANS OK TO SUBMIT - 3RD PARTY | 03/11/2005 | COMPLETED |
| 03/11/2005 | 3RD PARTY REVIEW-RESIDENTIAL | 07/13/2005 | COMPLETED |
| 07/13/2005 | POST 3RD PARTY REVIEW | 07/14/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM00051
Permit Status: Expired
Permit Description: NEW:FOURPLEX
Total Outstanding Activity Conditions - 4
| Date | Name |
|---|---|
| 01/05/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
| 07/13/2005 | SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED. |
| 07/13/2005 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
| 07/13/2005 | SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T05CM00051
Permite Description: NEW:FOURPLEX
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| OUTDOOR LIGHTING FINAL | N/A | Not Inspected | ||
| FIRE - FINAL | N/A | Not Inspected |
Completed Inspections
Permit Status: Expired
Permit Number: T05CM00051
Permit Description: NEW:FOURPLEX
Total Completed Inspections - 32
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/16/2005 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* 1) ABS DWV UNDERSLAB OK 2) WATER TEST ONE RISER TO TEN FEET 3) PEX LOOPED UNDERSLAB 4) DON'T FORGET TO WRAP YOUR PIPE-PRE POUR |
| 12/30/2005 | ELECTRIC - UFER | CCLEMENS | Approved | IVRS - Inspection :* 1) OK TO COVER UFER 2) NOTE: TIE UFER OFF AT 20' |
| 12/30/2005 | BUILDING PRE-SLAB | LHANLY | Approved | IVRS - Inspection :* |
| 12/30/2005 | EXCAVATION/LAYOUT REBAR & ZON | LHANLY | Approved | IVRS - Inspection :* |
| 03/22/2006 | EXT METAL CLIPS/EXT SHEATHING | AQUIROZ | Approved | A-35 CLIPS OK AT ROOF LINE |
| 04/26/2006 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection :* 1. TAP AT MAIN OK 4" SDR 35 WITH TRACER INSTALLED TO P.L CLEANOUT OK TO COVER WATER TEST OK |
| 05/07/2006 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection :* 1. SEWER OK YARDWATER OK OK TO COVER |
| 05/07/2006 | SITE - SEWER | RMYERS | Approved | IVRS - Inspection :* |
| 06/19/2006 | U VALUE FOR WINDOW | AQUIROZ | Approved | IVRS - Inspection :* |
| 06/19/2006 | STUCCO MESH | AQUIROZ | Approved | IVRS - Inspection :* |
| 06/19/2006 | ROOF NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 06/21/2006 | MECHANICAL - PROGRESS | CWILLIAM | Approved | IVRS - Inspection :* |
| 06/21/2006 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection :* |
| 06/28/2006 | ELECTRIC - CABLE DROP | CCLEMENS | Approved | IVRS - Inspection :* |
| 06/28/2006 | FRAMING | AQUIROZ | Approved | IVRS - Inspection :* |
| 07/19/2006 | ELECTRIC - PROGRESS | RMAJUTA | Approved | |
| 08/07/2006 | ELECTRIC - INTERMEDIATE | CCLEMENS | Approved | IVRS - Inspection :* 1) DO NOT ENERGIZE ANY CKT'S UNTILL ALL IS TRIMMED AND SAFED OFF |
| 08/07/2006 | ELECTRIC - TEMPORARY SERVICE | CCLEMENS | Approved | IVRS - Inspection :* |
| 08/08/2006 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED FOR UNITS #1202, 1201, 1102 & 1101 PER C. CLEMENS |
| 08/18/2006 | PLUMBING - INTERMEDIATE | IVR USER | Approved | IVRS - AP canceled |
| 08/21/2006 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* PLUMBING FINAL OK OK FOR C OF O S.T.O.I |
| 08/21/2006 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection :* |
| 08/21/2006 | PLUMBING - FINAL | RMYERS | Approved | COPPER MAY NOT BE DIRECTLY EMBEDDED IN CONCRETE. |
| 08/21/2006 | PLUMBING - PROGRESS | RMYERS | Approved | |
| 08/21/2006 | PLUMBING - GAS PRESS TEST FNL | RMYERS | Approved | |
| 08/21/2006 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | |
| 08/21/2006 | PLUMBING - ABOVE CEILING | RMYERS | Approved | |
| 08/22/2006 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
| 08/22/2006 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | |
| 08/28/2006 | ELECTRIC - OUTDOOR LIGHTING | CCLEMENS | Approved | IVRS - Inspection :* |
| 08/30/2006 | ELECTRIC - FINAL | CCLEMENS | Approved | IVRS - Inspection :* |
| 08/31/2006 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection :* |