Inspection History Details
Inspection Status: Cancelled
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/18/2006 | PLUMBING - INTERMEDIATE | Cancelled | IVRS - AP canceled | |
| 08/16/2006 | PLUMBING - INTERMEDIATE | Cancelled | IVRS - AP canceled | |
| 07/11/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | WHO GAVE PERMISSION TO COVER WALLS AND CEILINGS? NO PORTION OF ANY WORK MAY BE CONCEALED UNTIL IT HAS BEEN INSPECTED AND APPROVED. THIS INCLUDES DRYWALL AND INSULATION. |
|
| 07/10/2006 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* OK TO COVER ALL AREAS CLOSET FLANGES OK |
|
| 06/30/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) NEED TO SEE 1ST FLOOR CLOSET FLANGES SECURED 2) FHA STRAPS AS REQUIRED 3) OK TO COVER WALLS |
|
| 06/29/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 06/26/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. NO AVB'S - NO TEST ON ABS - PLEASE MAKE ALL CORRECTIONS BEFORE RECALLING INSPECTION. - PLEASE POST YOUR ADDRESS - INSPECTION STOPPED. |
|
| 06/22/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* UNABLE TO LOCATE PLANS. 1. WATER USED DURING CONSTRUCTION SHALL BE PROTECTED BY A VACUUM BREAKER. 2. NOT UNDER TEST - DWV 3. TUBS NOT FULL 4. CLOSET FLANGES NOT SECURED TO FLOOR. 5. SWEEPS REQUIRED. 6. 18" OF COPPER TUBE BETWEEN PEX AND SOLDER VALVES (WATER SERVICE). 7. TRAP ARMS REQUIRE 1/4" PER SLOPE 8. WH DRAIN PANS REQUIRES ON SUBFLOOR. 9. SHOWER HEAD RISERS NOT UNDER TEST. 10. 2ND STORY SINKS AND WASHER BOXES REQUIRE CLEAN OUTS FOR HORIZONTAL PIPING BELOW SLAB PER TUCSON CODE AMENDMENTS. |