Permit Details

Status:
Final
Type:
COMMERCIAL OTHER
Address NEW:
5335 E BROADWAY BL
Apply Date:
12/27/2004
Applicant:
METRO PERMIT EXPRESS, INC
Description:
INSTALL:NEW ELEVATORS
Architects:
  • FRANKS, MICHAEL WILLIAM
Contractors:
  • YARBOROUGH DEVELOPMENT INC

Permit Reviews

Permit Number - T04CM05570
Permit Status: Final
Permit Description: INSTALL:NEW ELEVATORS
Start Date Submittal Complete Date Status  
01/26/2005 POST 3RD PARTY REVIEW 02/04/2005 COMPLETED Review Details
06/01/2005 REVISION 06/02/2005 COMPLETED Review Details
07/03/2006 3RD PARTY REVIEW-REVISION/OTHER 07/14/2006 COMPLETED Review Details
08/15/2006 OTHER 08/15/2006 COMPLETED Review Details
11/09/2006 3RD PARTY REVIEW-REVISION/OTHER 11/09/2006 COMPLETED Review Details
12/27/2004 PLANS OK TO SUBMIT - 3RD PARTY 12/29/2004 COMPLETED Review Details
12/29/2004 3RD PARTY REVIEW-COMMERCIAL TI 01/26/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T04CM05570
Permit Status: Final
Permit Description: INSTALL:NEW ELEVATORS
Total Outstanding Activity Conditions - 1
Date Name
12/27/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T04CM05570
Permit Description: INSTALL:NEW ELEVATORS
Total Completed Inspections - 23
Date Description Inspector Results Comments
07/08/2005 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :* OK TO COVER DUCTING IN SHAFT
07/29/2005 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
1) OK FOR SHEETROCK
2) STILL NEED TO SEE WORK IN ELEVATOR ROOMS
08/04/2005 SHEET ROCK NAILING LHANLY Approved IVRS - Inspection :*
YOU NEED TO FIRESTOP ALL MEMBRANE PENETRATIONS @ SHAFT
08/29/2005 ELECTRIC - ABOVE CEILING DSANTACR Approved
08/29/2005 ELECTRIC - CONSTRUCTION POWER DSANTACR Approved IVRS - Inspection :*
09/15/2005 EXCAVATION/LAYOUT REBAR & ZON TRINIVJR Approved 1) PLUMBING FINAL IS OK
2) OK FOR C OF O
03/01/2006 PLUMBING - ROOF DRAINS RRICH Approved IVRS - Inspection :*
WATER TEST 3" RD + 3"DFRD FOR SOUTH ELEVATOR ROOF OK
08/03/2006 STEM WALL/RETAINING WALL JBURGE Approved IVRS - Inspection :*
08/03/2006 BUILDING PRE-SLAB JBURGE Approved IVRS - Inspection :*
11/01/2006 U VALUE FOR WINDOW JBURGE Approved IVRS - Inspection :*
11/01/2006 BUILDING ABOVE CEILING JBURGE Approved IVRS - Inspection :*
11/01/2006 FRAMING JBURGE Approved IVRS - Inspection :*
11/01/2006 EXT METAL CLIPS/EXT SHEATHING JBURGE Approved IVRS - Inspection :*
11/01/2006 REINFORCED MASONRY PRE-GROUT JBURGE Approved IVRS - Inspection :*
11/01/2006 ROOF NAILING JBURGE Approved IVRS - Inspection :*
11/02/2006 ELECTRIC - INTERMEDIATE RHOLLAND Approved IVRS - Inspection :*
1) CONDUITS TO BE AS PER 300.5
2) HAVE FULL REVISED PLANS ON SITE WITH STAMPED APPROVAL FOR FINAL
3) OK TO COVER AND ENCASE
12/28/2006 PLUMBING - FINAL IVR USER Approved IVRS - AP canceled
1) EMBASSY SUITES: POST ADDRESS PRIOR TO ANY MORE INSPECTIONS BY ROOM 116
2) PROVIDE PLANS
12/29/2006 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) NO CONTRACTOR ON SITE
12/29/2006 ELECTRIC - FINAL RHOLLAND Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) BACK FED BREAKER TO USE MANUFACTURERS HOLDOWN
2) PVC CONDUIT TO BE AS PER 300.5
3) FUSES NOT PER PLANS
4) TAPS NOT PER PLANS, PLEASE VERIFY TRP ? 240.21
5) PLANS DO NOT HAVE CITY STAMP-3RD INSPECTION
6) TIGHTEN LOOSE FITTINGS AND STRAPS-USE APPROVED STRAPING METHODS
7) PLEASE RELEASE REFEE BEFORE NEXT INSPECTION
12/29/2006 BUILDING - FINAL JBURGE Approved IVRS - Inspection :*
12/29/2006 FIRE - FINAL LTHOMAS Approved
12/29/2006 FIRE SPKLR - FINAL LTHOMAS Approved
01/17/2007 PERMIT FINALED BFLORES Approved

Documents

File Name Document Type  
T04CM05570 2025 MASS-UPLOAD.PDF DOCUMENTS VIEW
None DOCUMENTS VIEW
None CONSTRPLANS VIEW