Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T04CM05570
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/01/2006 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
| 08/24/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* WALLS TO 38' OK TO GROUT |
|
| 08/22/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* WALLS TO 32; LINTEL SET ON W.SIDE. |
|
| 08/21/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* PERIMETER WALLS TO 28' -- OK TO GROUT |
|
| 08/17/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* WALLS TO 24' -- OK TO GROUT |
|
| 08/16/2006 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* CONTRACTOR CANCELLED |
|
| 08/11/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NORTH ELEVATOR 16'-20' GROUTED |
|
| 08/10/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* OK TO GROUT TO 16' |
|
| 08/09/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 9'4" TO 16 - DOWELS EPOXIED ON WEST SIDE NEED CLARIFICATION CONCERNING SOUTH WALL AT ADJACENT DECK FOR EPOXY ANCHORING (ARCHITECT TO CLARIFY) |
|
| 08/08/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* TO 12' -- OK TO GROUT |
|
| 08/07/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* PARTIAL TO 8' OK TO POUR |
|
| 08/03/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 02/08/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SOUTH ELEVATOR (32'-36'8" ABOVE FOUNDATION); COLUMNS FOR ROOM @ SOUTH SIDE OF SOUTH ELEVATOR (20'-22'4") *NEED TO SEE SPECIAL INSPECTION REPORT FOR 2/7/06 (28'-32' @ SOUTH ELEVATOR) |
|
| 02/07/2006 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :*INCOMPLETE INSPECTION | |
| 02/06/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) SOUTH ELEVATOR (24'-28' ABOVE FOUNDATION); COLUMNS FOR ROOM AT SOUTH SIDE OF SOUTH ELEVATOR (16'-20' ABOVE FOUNDATION) |
|
| 02/03/2006 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* INCOMPLETE INSPECTION |
|
| 02/02/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* *CALLED TO LATE FOR I.V.R FOR SCHEDULING WOULD ONLY ALLOW CONTRACTOR TO SCHEDULE FOR 2/3/06 ITEM 01020: SOUTH ELEVATOR (24'-28' ABOVE FOUNDATION); COLUMNS FOR ROOM @ SOUTH SIDE OF SOUTH ELEVATOR (12'-16' ABOVE FOUNDATION) |
|
| 02/01/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) SOUTH ELEVATOR (20'-24' ABOVE FOUNDATION) ; COLUMNS FOR ROOM AT SOUTH SIDE OF SOUTH ELEVATOR (8'-12' ABOVE FOUNDATION) |
|
| 01/31/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) SOUTH ELEVATOR (16'-20' ABOVE FOUNDATION) |
|
| 01/23/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) SOUTH ELEVATOR (12'-16' ABOVE FOUNDATION) |
|
| 01/22/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SOUTH ELEVATOR (8'-12') NEED TO SEE SPECIAL INSPECTIONS REPORTS ON SITE |
|
| 01/19/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SOUTH ELEVATOR (4'-8') |
|
| 01/18/2006 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* |