Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL NEW
Address:
2480 E RIVER RD
Apply Date:
11/16/2004
Applicant:
N/A
Description:
OFFICE BUILDING 69' X 38'9" + 28'3" x 16'8" L-SHAPED BUILDING, ONE-STORY OF MASONRY WALLS FURRED-OUT W/WOOD STUDS AND GYP BD, WOOD COLUMNS, ROOF BEAMS OF STEEL, GLU-LAM AND SOLID WOOD, TJI ROOF JOISTS AND OSB ROOF SHEATHING 1ST REVISION : TRUS JOIST SUBMITTAL APPROVED BY ENGINEER OF RECORD. APPROVED (2/3/06)(DGL).
Architects:
  • ROBINETTE, RONALD WILLIAM
Contractors:
  • EPSTEIN FENTON L L C ,

Permit Reviews

Permit Number - T04CM05036
Permit Status: C of o
Permit Description: OFFICE BUILDING 69' X 38'9" + 28'3" x 16'8" L-SHAPED BUILDING, ONE-STORY OF MASONRY WALLS FURRED-OUT W/WOOD STUDS AND GYP BD, WOOD COLUMNS, ROOF BEAMS OF STEEL, GLU-LAM AND SOLID WOOD, TJI ROOF JOISTS AND OSB ROOF SHEATHING 1ST REVISION : TRUS JOIST SUBMITTAL APPROVED BY ENGINEER OF RECORD. APPROVED (2/3/06)(DGL).
Start Date Submittal Complete Date Status  
01/30/2006 REVISION - - 1ST 02/27/2006 COMPLETED Review Details
03/02/2005 RESUBMITTAL 04/20/2005 COMPLETED Review Details
03/02/2005 SITE 04/20/2005 COMPLETED Review Details
05/04/2005 RESUBMITTAL - SITE 05/31/2005 COMPLETED Review Details
05/04/2005 RESUBMITTAL 05/31/2005 COMPLETED Review Details
06/08/2005 RESUBMITTAL - SITE 07/19/2005 COMPLETED Review Details
06/08/2005 RESUBMITTAL 06/20/2005 COMPLETED Review Details
06/20/2005 RESUBMITTAL 07/19/2005 COMPLETED Review Details
11/16/2004 PLANS OK TO SUBMIT - COMM 11/16/2004 COMPLETED Review Details
11/16/2004 SITE 11/16/2004 COMPLETED Review Details
11/16/2004 COMMERCIAL NEW 01/24/2005 COMPLETED Review Details
11/16/2004 SITE 01/24/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T04CM05036
Permit Status: C of o
Permit Description: OFFICE BUILDING 69' X 38'9" + 28'3" x 16'8" L-SHAPED BUILDING, ONE-STORY OF MASONRY WALLS FURRED-OUT W/WOOD STUDS AND GYP BD, WOOD COLUMNS, ROOF BEAMS OF STEEL, GLU-LAM AND SOLID WOOD, TJI ROOF JOISTS AND OSB ROOF SHEATHING 1ST REVISION : TRUS JOIST SUBMITTAL APPROVED BY ENGINEER OF RECORD. APPROVED (2/3/06)(DGL).
Total Outstanding Activity Conditions - 1
Date Name
11/16/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T04CM05036
Permit Description: OFFICE BUILDING 69' X 38'9" + 28'3" x 16'8" L-SHAPED BUILDING, ONE-STORY OF MASONRY WALLS FURRED-OUT W/WOOD STUDS AND GYP BD, WOOD COLUMNS, ROOF BEAMS OF STEEL, GLU-LAM AND SOLID WOOD, TJI ROOF JOISTS AND OSB ROOF SHEATHING 1ST REVISION : TRUS JOIST SUBMITTAL APPROVED BY ENGINEER OF RECORD. APPROVED (2/3/06)(DGL).
Total Completed Inspections - 38
Date Description Inspector Results Comments
11/02/2005 PLUMBING - ROUGH, SOIL TRINIVJR Approved IVRS - Inspection :*SOIL WATER TEST IS OK
COMBO ON FOOT VENT FOR ILAND LOOP IS OK
OK TO BACKFILL TRENCH
1 1/2" C.W INTO BLDG IS OK AIR PRESSURE TEST IS OK
11/02/2005 PLUMBING - YARD WTR LINE/TEST TRINIVJR Approved IVRS - Inspection :*
12/05/2005 BUILDING PRE-SLAB JCAGLE Approved IVRS - Inspection :*FOOTING & PRE SLAB OK. NEED TO VERIFY SETBACK FROM PROPERTY LINES. PLEASE PROVIDE ?? CERTS FROM SURVEYOR. PLACING CONCRETE WILL BE @ YOUR OWN RISK.
12/05/2005 ELECTRIC - UNDERGROUND CCLEMENS Approved IVRS - Inspection :*OK TO COVER UFER.
MAKE SURE WATER BOND IS ACCESSIBLE
12/05/2005 EXCAVATION/LAYOUT REBAR & ZON JCAGLE Approved IVRS - Inspection :*
04/11/2006 ROOF NAILING AQUIROZ Approved IVRS - Inspection :*
04/11/2006 EXT METAL CLIPS/EXT SHEATHING AQUIROZ Approved IVRS - Inspection :*
05/03/2006 PLUMBING - PROGRESS RMYERS Approved IVRS - Inspection :*
05/03/2006 PLUMBING - ROOF DRAINS RMYERS Approved IVRS - Inspection :*
05/03/2006 PLUMBING - ABOVE CEILING RMYERS Approved IVRS - Inspection :*
05/25/2006 ELECTRIC - UFER CCLEMENS Approved IVRS - Inspection :*
1. WATER, GAS AND SPRINKLER PIPES MUST BE BONDED TO THE SERVICE AND SIZED PER NEC 250.66 ALL BONDING CONNECTIONS MUST BE ACCESSIBLE - THEY ARE NOT IN OR ACCESSIBLE AT THIS TIME.
WITH THIS IN MIND, OK TO COVER ELECTRICAL IN WALLS AND CEILINGS - WILL CHECK BONDING AT FINAL.
05/25/2006 MECHANICAL - ABOVE CEILING CWILLIAM Approved IVRS - Inspection :*
05/25/2006 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection :*
05/25/2006 ELECTRIC - ABOVE CEILING CCLEMENS Approved IVRS - Inspection :*
05/25/2006 ELECTRIC - INTERMEDIATE CCLEMENS Approved IVRS - Inspection :*
05/25/2006 REINFORCED MASONRY PRE-GROUT AQUIROZ Approved IVRS - Inspection :*
05/30/2006 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection :*
1. YARDWATER OK
2. INTERMEDIATE OK TO COVER ALL AREAS
06/06/2006 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection :*
06/16/2006 STUCCO MESH AQUIROZ Approved IVRS - Inspection :*
09/21/2006 ELECTRIC - TEMP POWER FOR TEST CCLEMENS Approved IVRS - Inspection :*
1. REMOVE ALL PANEL COVERS FOR INSPECTION
2. FINISH TRIM NO OPEN WIRING FOR POWER
3. PROVIDE LADDER ACCESS TO EXTERIOR GUTTER.
09/27/2006 ELECTRIC - TEMPORARY SERVICE RSUBA Approved IVRS - Inspection :*
09/27/2006 ELECTRIC - CABLE DROP RSUBA Approved IVRS - Inspection :*
09/27/2006 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED VIA PHONE CONVERSATION WITH R. SUBA
11/21/2006 FIRE - FINAL LTHOMAS Approved
11/21/2006 FIRE SPKLR - OH PIPING & HYDRO LTHOMAS Approved
11/21/2006 FIRE SPKLR - UG PIPING FLUSH LTHOMAS Approved
11/21/2006 FIRE SPKLR - UG, PIPING, HYDRO LTHOMAS Approved
11/21/2006 FIRE SPKLR - FINAL LTHOMAS Approved
11/21/2006 BUILDING - FINAL AQUIROZ Approved IVRS - Inspection :*
11/21/2006 FRAMING AQUIROZ Approved IVRS - Inspection :*
11/21/2006 STEM WALL/RETAINING WALL AQUIROZ Approved IVRS - Inspection :*
11/21/2006 SIGN - FINAL JYBARRA Approved IVRS - Inspection :*
11/22/2006 PLUMBING - FINAL RMYERS Approved IVRS - Inspection :*
PLUMBING FINAL OK
OK FOR C OF O
S.T.O.I
12/19/2006 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :
See detailed listing on site.| 999*
BLOWER COMPARTMENT CANNOT BE ACCESSED WITHOUT DISMANTLING THE UNIT. UNIT DOES NOT HAVE CLEARANCE FROM WALL ON ROOF. RECOMMED RELOCATING UNIT & DUCTING OVER TO THE EXISTING LOCATION OR FILE FOR AN APPEAL WITH THE CODE ADMINISTRATOR.
12/19/2006 ELECTRIC - FINAL CCLEMENS Approved IVRS - Inspection :
See detailed listing on site.| 999*
1. PANEL DIRECTORY STILL NOT CORRECT GO THROUGH ALL CKT'S AND MAKE SURE PANEL DIRECTORY GOES TO WHAT IT SAYS ITS GOING TO.
2. HAVE ALL COVER PLATES ON DEVICES FOR INSPECTION.
3. RTU'S STILL DO NOT HAVE REQUIRED SERVICE ACCESS.
12/20/2006 NPPO - FINAL ACONNOR Approved
12/20/2006 LANDSCAPE - FINAL ACONNOR Approved
01/12/2007 PERMIT FINALED BFLORES Approved

Documents

File Name Document Type  
ENERGYCODECALC.TIF DOCUMENTS VIEW
TRUSCALC.TIF DOCUMENTS VIEW
A/CREPORT.TIF DOCUMENTS VIEW
INTERNATIONALENERGYCODE.TIF DOCUMENTS VIEW
BALANCEREPORT.TIF DOCUMENTS VIEW
FAULTCURRENTSTUDY.TIF DOCUMENTS VIEW
GEOTECHNICALEVALUATION.TIF DOCUMENTS VIEW
None DOCUMENTS VIEW
COFO_02-05-2007.TIF CERT OF OCC VIEW
SITE PLAN_06-23-2005.TIF CONSTRPLANS VIEW
T04CM05036_002.TIF CONSTRPLANS VIEW