Permit Number: T04CM05036
Parcel: 108240920

Address:
2480 E RIVER RD

Review Status: Completed

Review Details: SITE

Permit Number - T04CM05036
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/03/2005 JIM EGAN FIRE REVIEW Approved
03/11/2005 BLANCA ESPINO ENGINEERING REVIEW Approved assignment per JPV
03/15/2005 PETER MCLAUGHLIN ZONING HC SITE REVIEW Approved
03/15/2005 PETER MCLAUGHLIN ZONING REVIEW Denied SITE PLAN TRANSMITTAL

TO: Epstein/ Fenton, LLC
4855 N. Shamrock Place 109 Tucson, AZ 85705
(520) 806-4000

FROM: Peter McLaughlin
Senior Planner
Development Services Dept.

FOR: Patricia Gehlen
Principal Planner
Development Services Dept.

PROJECT:
T04CM05036
Lot 13
Hacienda Del Sol Office Complex
2480 E. River Road
Site Plan Review (2nd review)

TRANSMITTAL: March 15, 2005


COMMENTS: Upon completion of the following revisions/additions, an over the counter review may be arranged to obtain stamped approval by the zoning review section without resubmitting the site plan. The following item must be revised on or added to the site plan:

1. On sheet C2 in the setback information table under the Code Check heading to "see LDO". Revise table to state the correct setbacks required and provided. The table states that a minimum 10-foot setback is provided along the rear (south) property line but a proposed setback of 7' - 5" is shown on the drawing for the 1-hour fire wall, which is proposed at 15'-8" AFG. Provide stamped approved LDO copies of the site plan along with a copy of the LDO approval letter. Add the LDO case number, date of approval and any conditions imposed to the site plan notes. Also, add the zoning of the adjacent zoning to the south (R-3) to the drawing on sheet C-1.
LUC 3.2.6.4
DS 2-02.2.1.A.7
DS 2-02.2.1.A.38

2. According to the final plat for Hacienda del Sol office complex, the page number of recordation for the storm drain easement running across Lot 13 should read: Page 2096 rather than Page 482, which is the page number of recordation for a nearby public water easement. Revise per final plat.
DS 2-02.2.1.A.20

If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.
03/24/2005 ANDREW CONNOR NPPO REVIEW Approv-Cond
03/24/2005 ANDREW CONNOR LANDSCAPE REVIEW Approv-Cond

Final Status

Task End Date Reviewer's Name Type of Review Description
04/20/2005 CINDY AGUILAR OUT TO CUSTOMER Completed
04/20/2005 CINDY AGUILAR REJECT SHELF Completed