Permit Number: T04CM05036
Parcel: 108240920

Address:
2480 E RIVER RD

Review Status: Completed

Review Details: SITE

Permit Number - T04CM05036
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/17/2004 Jim Egan FIRE REVIEW Approved
11/18/2004 BLANCA ESPINO ENGINEERING REVIEW Denied Site Plan
1. Please include a response letter with the next submittal that states how all comments have been addressed. Include plans/redlines from previous plan submittal.

2. Indicate location map on site plan. D.S. 2-02.2.1.A.4

3. It appears that the south and southwest lot lines have been changed according to the approved Development Plan. Indicate correct lot dimensions and bearings. Correct and revise. D.S. 2-02.2.1.A.5

4. Indicate roof slope and location of downspouts. D.S. 2-02.2.1.A.6
Add note, "All roof spouts will be routed under any adjacent sidewalk." D.S. 2-08.3.1 & 4.1.E

5. If applicable, indicate location, type, size and height of existing and proposed signage. D.S. 2-02.2.1.A.13

6. Indicate drainage patterns and finish grades. Do not obstruct offsite to onsite flows. D.S. 2-02.2.1.A.16

7. Indicate estimated cut and fill quantities. D.S. 2-02.2.1.A.17

8. If applicable, indicate all easements of record to be graphically shown on the plan together with recording docket and page reference. D.S. 2-02.2.1.A.20

9. Indicate location and orientation of existing major physical features, such as drainageways. D.S. 2-02.2.1.A.22

10. Indicate existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number. D.S. 2-02.2.1.A.23

11. Indicate refuse container location, size and access thereto fully dimensioned.
11/29/2004 ANDREW CONNOR NPPO REVIEW Denied Submit NPP and landscape plans included in approved case #'s D01-038 or S01-0045 to continue review.
11/29/2004 Andrew Connor LANDSCAPE REVIEW Denied Submit NPP and landscape plans included in approved case #'s D01-038 or S01-0045 to continue review.
12/16/2004 Peter McLaughlin ZONING REVIEW Denied SITE PLAN TRANSMITTAL

TO: Epstein/ Fenton, LLC
4855 N. Shamrock Place 109 Tucson, AZ 85705
(520) 806-4000

FRPM: Peter McLaughlin
Senior Planner
Development Services Dept.

FOR: Patricia Gehlen
Principal Planner
Development Services Dept.

PROJECT:
T04CM05036
Lot 13
Hacienda Del Sol Office Complex
2480 E. River Road
Site Plan Review (1st review)

TRANSMITTAL: December 17, 2004


COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.
CODE SECTION/
DEVELOPMENT
STANDARD

1. The lot dimensions on the site plan sheets C-1 and C-2 do not match those shown on the final plat. Revise drawing accordingly. Further comments regarding setbacks may be required once the correct lot dimensions are shown.
DS 2-02. 2.1.A.5

2. Revise the site plan label (below the drawing and to the left of the north arrow) on sheet C-2 to indicate that this is lot 13, not lot 12 of Hacienda del Sol Office Complex.
DS 2-02.2.1.A.2

3. Show the layout of parking correctly on the drawings on C-1 and C-2, including the required handicap parking spaces and aisles per the approved tentative plat. DS 2-02.2.1.A.8

4. Add the 20-foot wide private storm drain easement and the recordation information (Docket 11948 Page 2096) to the site plan drawing per the final plat.
DS 2-02.2.1.A.20

If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.
12/17/2004 PETER MCLAUGHLIN ZONING HC SITE REVIEW Denied See zoning review comments.

Final Status

Task End Date Reviewer's Name Type of Review Description
01/24/2005 DELMA ROBEY OUT TO CUSTOMER Completed