Permit: T04CM01934
Permit Details
Apply Date:
04/29/2004
Applicant:
EDUARDO ORNELAS
Description:
NEW RESTAURANT
Contractors:
- CENDOT CONSTRUCTION L L C
Outstanding Activity Conditions
Permit Number - T04CM01934
Permit Status: C of o
Permit Description: NEW RESTAURANT
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/29/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T04CM01934
Permit Description: NEW RESTAURANT
Total Completed Inspections - 34
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/10/2005 | ELECTRIC - UFER | DSANTACR | Approved | IVRS - Inspection :* |
| 11/18/2005 | PLUMBING - SEWER HCS CONNECT | RRICH | Approved | IVRS - Inspection :*4" ABS SEWER FROM EXISTING SEWER HCS BACK TO 10' FROM SOUTH END OF BUILDING WATER TEST OK 1) WILL NEED TO SEE BUILDING CONNECTION WITH 2 -WAY CLEANOUT. |
| 11/29/2005 | REINFORCED MASONRY PRE-GROUT | AMATHIES | Approved | IVRS - Inspection :*PATIO WALL NEEDS A STRAIGHT 2' WIDE FTG. CLEANED OUT WITH VERTICAL REBAR AS PER PLAN. STEM WALL OK BUT IT LOOKS LIKE YOU SHOULD HOLD DOWN BLOCK FOR 2 EAST DOORS |
| 11/29/2005 | STEM WALL/RETAINING WALL | AMATHIES | Approved | |
| 11/29/2005 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 12/05/2005 | PLUMBING - ROUGH, SOIL | BBENEDON | Approved | IVRS - Inspection :*WASTE & VENT PIPING TEST. UNDERGROUND & VENTS T042". 2 WAY CLEAN OUTS INSTALLED. OK TO COVER PROVIDE FOAM WRAPS TO PROTECT PIPING FROM CONCRETE. |
| 12/06/2005 | BUILDING PRE-SLAB | AMATHIES | Approved | IVRS - Inspection :* |
| 12/21/2005 | EXT METAL CLIPS/EXT SHEATHING | AMATHIES | Approved | IVRS - Inspection :* |
| 12/27/2005 | FRAMING | AMATHIES | Approved | IVRS - Inspection :* 1) FINAL FRAME WHEN ALL OTHER TRADES ARE OUT |
| 01/17/2006 | PLUMBING - ABOVE CEILING | BBENEDON | Approved | IVRS - Inspection :* 13.4 PSI ON GAS PIPING GAS PIPING IN WALL OK - ROUGH PRESSTURE TEST HOLDING PRESSURE TEST REQUIRED AFTER COVERING WALL PROVIDE RED LINES SHOWING WATER LINES ON EXTERIOR WATER PIPING OK WATER TEST ON DWV - OK PROVIDE LONG RADIUS 90 DEG. CHANGE OF DIRECTION ON MOP SINK CALL FOR CLOSET FLANGE AND FLOOR DRAIN INSPECTION WHEN READY. |
| 01/17/2006 | STUCCO MESH | LHANLY | Approved | IVRS - Inspection :* |
| 02/09/2006 | SHEET ROCK NAILING | LHANLY | Approved | IVRS - Inspection :* |
| 04/13/2006 | ELECTRIC - CABLE DROP | DSANTACR | Approved | IVRS - Inspection :* NOTES: OK TO CLEAR TEC - SUBJECT TO BOND POSTING. YOU MUST POST A BOND FOR TEMP POWER FOR TESTING, OR UPON APPROVAL OF OTHER FINAL INSPECTIONS, POWER CAN BE RELEASED. |
| 04/13/2006 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection :* |
| 04/21/2006 | ELECTRIC - TEMP POWER FOR TEST | DSANTACR | Approved | IVRS - Inspection :* 1) VERIFY BOND POSTED TEMP POWER |
| 04/24/2006 | TEP CLEARANCE - AM | JWEATHER | Approved | TEC CLEARED PER D. SANTACRUZ |
| 07/14/2006 | PLUMBING - YARD WTR LINE/TEST | RLEDONNE | Approved | IVRS - Inspection :* |
| 07/16/2006 | MECHANICAL - HOODS | CWILLIAM | Approved | |
| 07/16/2006 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | |
| 07/16/2006 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | |
| 07/16/2006 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection :* |
| 07/21/2006 | PLUMBING - GAS PRESSURE TEST | RLEDONNE | Approved | IVRS - Inspection :* GAS CARD ON PIPE AT TEST SETUP |
| 08/10/2006 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection :* |
| 08/28/2006 | PLUMBING - INTERMEDIATE | RLEDONNE | Approved | IVRS - Inspection :* |
| 09/08/2006 | PLUMBING - BACK WATER VALVE | RLEDONNE | Approved | |
| 09/08/2006 | PLUMBING - FINAL | RLEDONNE | Approved | IVRS - Inspection :* |
| 11/09/2006 | BUILDING - FINAL | AALEGRIA | Approved | IVRS - Inspection :* IN COMPLIANCE WITH APPROVED PLANS AND SPECIFICATIONS STRUCTURE (BUILDING) AND USES SHALL CONFORM TO THE STRUCTURE STRENGTH, FIRE SAFETY, ACCESSIBILITY OK TO OCCUPANCY |
| 11/15/2006 | HEALTH DEPT - FINAL 724-7908 | RBROWNIN | Approved | |
| 11/20/2006 | FIRE - FINAL | LLAKEY | Approved | |
| 11/20/2006 | FIRE - KITCHEN EXH HOOD FINAL | LLAKEY | Approved | |
| 11/20/2006 | NPPO - FINAL | ACONNOR | Approved | N/A |
| 11/20/2006 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
| 11/21/2006 | RIGHT OF WAY - FINAL | LLOPEZ | Approved | PER EMAIL |
| 12/11/2006 | ENGINEERING - FINAL | MAVERY | Approved | Contractor completed punch list. |