Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
COMMERCIAL OTHER
Address NEW:
4670 N CIRCUIT RD 02
Apply Date:
03/02/2004
Applicant:
METRO PERMIT EXPRESS, INC
Description:
GRADING:950 CY CUT & 1025 CY FILL
Architects:
  • ACORN, KIM BRIAN
Contractors:
  • CHESTNUT CONSTRUCTION CORPORATIO

Permit Reviews

Permit Number - T04BU00491
Permit Status: Final
Permit Description: GRADING:950 CY CUT & 1025 CY FILL
Start Date Submittal Complete Date Status  
02/08/2005 REVISION - GRADING 02/08/2005 COMPLETED Review Details
03/02/2004 PLANS OK TO SUBMIT - GRADING 03/02/2004 COMPLETED Review Details
03/02/2004 GRADING 04/06/2004 COMPLETED Review Details
04/23/2004 RESUBMITTAL - GRADING ALL 05/10/2004 COMPLETED Review Details
05/12/2004 RESUBMITTAL - GRADING ALL 05/24/2004 COMPLETED Review Details
07/30/2004 REVISION - GRADING 08/25/2004 COMPLETED Review Details
08/25/2004 REVISION - GRADING 10/19/2004 COMPLETED Review Details
10/19/2004 RESUBMITTAL - GRADING 10/20/2004 COMPLETED Review Details
10/20/2004 REVISION - GRADING 11/03/2004 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T04BU00491
Permit Status: Final
Permit Description: GRADING:950 CY CUT & 1025 CY FILL
Total Outstanding Activity Conditions - 1
Date Name
03/02/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T04BU00491
Permit Description: GRADING:950 CY CUT & 1025 CY FILL
Total Completed Inspections - 8
Date Description Inspector Results Comments
06/01/2004 NPPO PRE PERMIT INSPECTION ACONNOR Approved
06/04/2004 ENGINEERING PRE-CONSTRUCTION JSALINE Approved I met with the superintendent on this date and discussed pre-construction issues regarding the storm water pollution plan. Future inspections for this site are scheduled.
06/14/2004 STORMWATER INSTALL OF CONTROLS JSALINE Approved SITE IS VERY FLAT AND STABLE. NO SILT FENCING HAS BEEN INSTALLED AT THIS TIME. SITE HAS NATURAL GRADE TO DRAIN TOWARDS THE PROPERTY TO THE NORTH WHICH IS OWNED BY THE SAME OWNER OF BOTH PROPERTIES. SITE DOES HOWEVER HAVE A CHAINLINK FENCE ALL AROUND THE PERIMETER. WILL SCHEDULE A RE-INSPECT IN ABOUT A MONTH.
12/20/2004 GRADING - FINAL JBRUCKME Approved 1. PROVIDE 13' CURB OPENINGS AT THE DRAINAGE ON THE DRIVEWAY BETWEEN LEXUS AND THIS PROJECT.
2. PROVIDE POSITIVE DRAINAGE FLOW FROM THE MAIN DRIVEWAY THROUGH THE TEST TRACK GROUTED ROCK RIP RAP.
3. COMPLETE ALL PAVING AND CURBS AS SHOWN ON THE GRADING PLAN.
4. PROVIDE SIDEWALK SCUPPERS AT ALL ROOF DOWNSPOUTS.
5. PROVIDE DRAWINGS AND CALCULATIONS FOR THE 6' X 2'8" WALL OPENING MODIFICATIONS ON THE EAST PERIMETER. SUBMIT TO C.O.T. ENGINEERING DIVISION FOR APPROVAL. THE WALL OPENING IS RESTRICTED BY THE ADJACENT BUILDING'S FOUNDATION AND SIDEWALK AND WILL NOT ALLOW COMPLETE FLOW THROUGH THE WALL OPENING.
6. CLEAN-UP AND REMOVE ALL CONSTRUCTION MATERIAL AND DEBRIS FROM THIS SITE AND THE ADJACENT LOT TO THE SOUTH THAT WAS DISTURBED DURING CONSTRUCTION ACTIVITY ON THIS SITE.
12/20/2004 STORMWATER FOLLOW-UP INSP JBRUCKME Approved STABILIZE THE AREA SOUTH OF THIS PROJECT OR PROVIDE APPRORIATE SEDIMENT AND EROSION CONTROLS.

CLEAN-UP AND REMOVE ALL CONSTRUCTION MATERIAL AND DEBRIS FROM THE STORMWATER DRAINAGE CHANNEL.
02/24/2005 STORMWATER FINAL INSPECTION JBRUCKME Approved
11/30/2005 LANDSCAPE INSPECTION ACONNOR Approved
05/31/2006 PERMIT FINALED LJACKSON Approved