Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T03CM05056
Permit Details
Apply Date:
10/23/2003
Applicant:
TRIUMPH BUILDERS SOUTHWEST LLC *C*
Description:
NEW:SHELL RETAIL/OFFICE BUILDING AND TI PER D MANN
Contractors:
- TRIUMPH BUILDERS SOUTHWEST LLC *C*
Permit Reviews
Permit Number - T03CM05056
Permit Status: C of o
Permit Description: NEW:SHELL RETAIL/OFFICE BUILDING AND TI PER D MANN
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
02/04/2004 | 3RD PARTY REVIEW-REVISION/OTHER | 02/09/2004 | COMPLETED |
03/08/2004 | 3RD PARTY REVIEW-REVISION/OTHER | 03/18/2004 | COMPLETED |
03/17/2004 | 3RD PARTY REVIEW-REVISION/OTHER | 04/01/2004 | COMPLETED |
10/23/2003 | PLANS OK TO SUBMIT - COMM | 10/27/2003 | COMPLETED |
10/23/2003 | PLANS OK TO SUBMIT - SITE | 10/23/2003 | COMPLETED |
10/28/2003 | 3RD PARTY REVIEW-COMMERCIAL | 11/03/2003 | COMPLETED |
11/11/2003 | 3RD PARTY REVIEW-COMMERCIAL TI | 11/24/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM05056
Permit Status: C of o
Permit Description: NEW:SHELL RETAIL/OFFICE BUILDING AND TI PER D MANN
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
10/23/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T03CM05056
Permit Description: NEW:SHELL RETAIL/OFFICE BUILDING AND TI PER D MANN
Total Completed Inspections - 45
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/26/2003 | ELECTRIC - CONSTRUCTION POWER | JORTA | Approved | IVRS - Inspection 0000* |
12/04/2003 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | IVRS - Inspection 0000* |
12/05/2003 | ELECTRIC - UFER | JORTA | Approved | IVRS - Inspection 0000*/ [2] UFER GROUNDING SYSTEM - ONE FOR SUITER AND OTHER FOR SUITE 100. APPROVED. |
12/12/2003 | STEM WALL/RETAINING WALL | AMATHIES | Approved | IVRS - Inspection 0000* COL STEM |
12/15/2003 | ELECTRIC - UNDERGROUND | DSANTACR | Approved | IVRS - Inspection 0000* |
12/19/2003 | BUILDING PRE-SLAB | AMATHIES | Approved | IVRS - Inspection 0000* |
12/23/2003 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection 0000*/ 1) CORRECTION MADE OK. 2) OK TO COVER. |
12/29/2003 | REINFORCED MASONRY PRE-GROUT | AMATHIES | Approved | IVRS - Inspection 0000* |
02/13/2004 | PLUMBING - SEWER HCS CONNECT | RRICH | Approved | IVRS - Inspection 0000*/ 4" BLD SEWER FROM 2-WAY CLEAN-OUT TO MAIN SEWER STUB UP AT 3 LOCATIONS WTR TEST APPROVED PER PLAN. 2" YARD WTR TEST APPROVED PER PLAN. |
02/13/2004 | PLUMBING - YARD WTR LINE/TEST | RRICH | Approved | IVRS - Inspection 0000* |
02/25/2004 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | |
02/25/2004 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection 0000* OK TO SHEATH PARAPET WALL |
03/01/2004 | EXT METAL CLIPS/EXT SHEATHING | AMATHIES | Approved | |
03/05/2004 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection 0000* |
03/08/2004 | PLUMBING - ABOVE CEILING | RRICH | Approved | |
03/08/2004 | SHEET ROCK NAILING | AMATHIES | Approved | DRY WALL TO EXTEND TO BOTTOM OF SHEATHING ON EXTERIOR WALL |
03/15/2004 | MECHANICAL - TEMP PWR FOR TEST | CWILLIAM | Approved | |
03/22/2004 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection 0000*/ 1) 25 PSI AIR TEST ON 4-1/2 LINES TO 4 ROOF TOP UNITS. 1-2" LINE TO 6-1" ROOF TOP UNITS APPROVED. CORRECTIONS MADE CLOSET FLANGES OK. INSULATION ON PIPING OK IN ACE BREAKROOM |
03/22/2004 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection 0000* |
03/22/2004 | ELECTRIC - CABLE DROP | DSANTACR | Approved | IVRS - Inspection 0000*/ 1) OK CABLE DROP, OK TEMP POWER FOR TEST SPACE # 100, SUBJECT TO BOND POSTING AND SIGN OFF SHEET OTHER INSPECTION |
03/23/2004 | PLUMBING - TEMP POWER FOR TEST | RRICH | Approved | |
03/23/2004 | TEP CLEARANCE - PM | JKOZUCH | Approved | |
03/23/2004 | ELECTRIC - TEMP POWER FOR TEST | DSANTACR | Approved | |
03/23/2004 | BUILDING - TEMP POWER FOR TEST | AMATHIES | Approved | |
03/25/2004 | STUCCO MESH | AMATHIES | Approved | IVRS - Inspection 0000* |
04/06/2004 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
04/07/2004 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection 0000* |
04/07/2004 | BUILDING ABOVE CEILING | AMATHIES | Approved | IVRS - Inspection :* |
04/07/2004 | FRAMING | AMATHIES | Approved | IVRS - Inspection :* |
04/12/2004 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | IVRS - Inspection 0000*/ SMOKE ALARMS, WHERE IS PERFORATED TUBE? INSIDE DUCT? SHOULD GO SIDE TO SIDE. WHERE IS SPEC SHEET SHIPPED WITH ALARM? |
04/13/2004 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved | IVRS - Inspection 0000* |
04/19/2004 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection 0000* |
04/23/2004 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | |
04/23/2004 | PLUMBING - GAS PRESS TEST FNL | RRICH | Approved | IVRS - Inspection :* |
04/26/2004 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :*/ CORRECTION MADE - ONE COPY OF BACKFLOW CERTIFICATION FOR ENTIRE BLD SERVICE. |
04/27/2004 | NPPO - FINAL | ACONNOR | Approved | |
04/27/2004 | LANDSCAPE - FINAL | ACONNOR | Approved | |
04/27/2004 | FIRE - FINAL | LTHOMAS | Approved | OK FOR C OF O |
04/27/2004 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection :*/ SHELL PERMIT AND ACE HARDWARE ONLY. |
04/27/2004 | OUTDOOR LIGHTING FINAL | DSANTACR | Approved | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* |
04/28/2004 | PERMIT FINALED | AMATHIES | Approved | |
04/28/2004 | RIGHT OF WAY - FINAL | LLOPEZ | Approved | |
04/28/2004 | ENGINEERING - FINAL | DROBERTS | Approved | |
04/28/2004 | BUILDING - FINAL | AMATHIES | Approved | |
04/28/2004 | U VALUE FOR WINDOW | AMATHIES | Approved |