Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Apply Date:
08/27/2003
Applicant:
TERRY GIBLETTO
Description:
TI:RETAIL TEMP C OF O FOR STOCKING ONLY
Architects:
  • FENECK, JOHN
Contractors:
  • PLUMB PLUMBING *C
  • SUNFLOWER MARKET

Permit Reviews

Permit Number - T03CM04246
Permit Status: C of o
Permit Description: TI:RETAIL TEMP C OF O FOR STOCKING ONLY
Start Date Submittal Complete Date Status  
01/14/2004 3RD PARTY REVIEW-REVISION/OTHER 02/02/2004 COMPLETED Review Details
03/04/2004 3RD PARTY REVIEW-REVISION/OTHER 03/05/2004 COMPLETED Review Details
08/27/2003 PLANS OK TO SUBMIT - COMM 08/28/2003 COMPLETED Review Details
08/29/2003 3RD PARTY REVIEW-COMMERCIAL TI 09/11/2003 COMPLETED Review Details
09/29/2003 3RD PARTY REVIEW-COMMERCIAL TI 10/15/2003 COMPLETED Review Details
10/15/2003 RESUBMITTAL 10/20/2003 COMPLETED Review Details
11/17/2003 3RD PARTY REVIEW-REVISION/OTHER 11/25/2003 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T03CM04246
Permit Status: C of o
Permit Description: TI:RETAIL TEMP C OF O FOR STOCKING ONLY
Total Outstanding Activity Conditions - 1
Date Name
08/27/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T03CM04246
Permit Description: TI:RETAIL TEMP C OF O FOR STOCKING ONLY
Total Completed Inspections - 28
Date Description Inspector Results Comments
10/29/2003 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection 0000*/ INSPECTION ON UNDERGROUND REFER LINES. OK TO COVER.
11/26/2003 PLUMBING - ROUGH, SOIL JSTANLEY Approved IVRS - Inspection 0000* OK TO BACK FILL
12/23/2003 PLUMBING - GAS PRESSURE TEST JSTANLEY Approved IVRS - Inspection 0000*/ WATER TEST OK ON WASTE VENTS AND WATER. PLEASE INSTALL VALVES AS PER PLAN. PROVIDE ACCESS TO ALL TRAP PRIMERS. PROVIDE MID-STORY ANCHORS ON VENTS AND WATER. COMPLETE VENT AT ICE MAKER. GAS - PARTIAL ONLY - PROVIDE VALVE BEFORE REGULATOR
12/23/2003 PLUMBING - INTERMEDIATE JSTANLEY Approved IVRS - Inspection 0000*
12/23/2003 ELECTRIC - INTERMEDIATE RHOLLAND Approved IVRS - Inspection 0000*/ 1) FINISH PANEL WALL 'M' & 'BD'. 2) FINISH WALL STORAGE WALL EAST SIDE. 3) PLEASE PROVIDE A LETTER AUTHORIZING USE OF SET SCREW CONNECTORS AND MC CABLE. ALSO NEW PANEL LOCATIONS. OK WALLS EXCEPT AS NOTED.
12/30/2003 FRAMING RSUBA Approved IVRS - Inspection 0000* SUBJECT REVISING PLANS REQARDING OFFICE
01/22/2004 MECHANICAL - HOODS JMILITEL Approved IVRS - Inspection 0000*
02/04/2004 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection 0000*/ 1) SUPPORT PVC CONDENSATE DRAINS MAXIMUM 4' SPACING 2) PROVIDE A DUCT SMOKE DETECTOR IN AIR HANDLER 3) PLANS CALL FOR 14" X 14" ALUMINIUM DUCT FOR BAKERY OVEN. PROVIDE LETTER FROM ENGINEER IF CHANGING. NEED TO SEE RELIEF VENTS ON COMPRESSORS AND CHILLER. OK FOR CEILING TILES. LEAVE OUT AROUND BAKERY OVEN. WILL CHECK CORRECTIONS ON FINAL 5) PLANS CALL FOR COMBUSTION AIR HIGH AND LOW IN EQUIPMENT ROOM FOR WATER HEATER
02/05/2004 PLUMBING - GAS PRESS TEST FNL JSTANLEY Approved IVRS - Inspection 0000*
02/06/2004 BUILDING ABOVE CEILING HLEYVA Approved
02/13/2004 MECHANICAL - TEMP PWR FOR TEST JMILITEL Approved IVRS - Inspection 0000*
02/13/2004 PLUMBING - TEMP POWER FOR TEST JSTANLEY Approved IVRS - Inspection 0000*/ C OF O SUBJECT TO STEVE LONG.
02/13/2004 BUILDING - TEMP POWER FOR TEST RSUBA Approved IVRS - Inspection 0000*
02/17/2004 RIGHT OF WAY - FINAL PWHIDDON Approved
02/17/2004 ENGINEERING - FINAL DROBERTS Approved
03/09/2004 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection 0000*/ OK FOR FINAL C OF O.
03/09/2004 MECHANICAL - HOOD SYSTEMS JMILITEL Approved
03/09/2004 FIRE SPKLR - FINAL CSCHULTZ Approved
03/10/2004 ELECTRIC - FINAL RHOLLAND Approved IVRS - Inspection 0000*
03/10/2004 ELECTRIC - TEMP POWER FOR TEST RHOLLAND Approved
03/10/2004 ELECTRIC - CONSTRUCTION POWER RHOLLAND Approved
03/10/2004 ELECTRIC - ABOVE CEILING RHOLLAND Approved IVRS - Inspection 0000*
03/11/2004 FIRE - FINAL CSCHULTZ Approved
03/12/2004 SIGN - FINAL JYBARRA Approved IVRS - Inspection 0000*
03/12/2004 BUILDING - FINAL RSUBA Approved IVRS - Inspection 0000*
03/12/2004 SHEET ROCK NAILING RSUBA Approved
03/15/2004 PERMIT FINALED JSTANLEY Approved
03/15/2004 PLUMBING - FINAL JSTANLEY Approved IVRS - Inspection 0000*

Documents

File Name Document Type  
None CERT OF OCC VIEW